Inventory
Safety and General Information
Inspect the package contents upon receipt. Notify the 
carrier and dealer if there is any damage.
Read the Safety Guide supplied with this unit before 
installing the UPS.
•  This UPS is intended for indoor use only. 
•  Do not operate this UPS in direct sunlight, in contact with fluids, or where there is 
excessive dust or humidity.
•  Be sure the air vents on the UPS are not blocked. Allow adequate space for proper 
ventilation.
•  The battery typically lasts for two to three years. Environmental factors impact 
battery life. Elevated ambient temperatures, poor quality AC power, and frequent 
short duration discharges will shorten battery life.
•  Connect the UPS power cable directly to a wall outlet. Do not use surge protectors 
or extension cords
Specifications
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected. Remove the “Stop! 
Connect the Battery” label that covers the outlets. Prior to connecting any equipment 
to the unit, connect the battery cable to the unused battery terminal. It is normal for 
small sparks to be seen when the battery cable is connected to the battery terminal.  
Wall Mount Installation
• Horizontal installation, use 2 screws 7.3" (186.3 mm) apart. 
• Vertical installation, use 2 screws 5.4" (137.2 mm) apart. 
• Allow 5/16” (8 mm), of the screw to protrude from the wall.
Replace Battery
Use only approved APC by Schneider Electric replacement battery cartridges.
Deliver used batteries to a battery replacement facility in the packaging provided by 
APC by Schneider Electric with the replacement battery cartridge. Battery 
replacement part for Back-UPS BN575G is APCRBC110. To order replacement 
battery cartridges contact APC by Schneider Electric 
Connect Equipment
Battery Backup + Surge Protection Outlets
Battery backup outlets provide protection to connected equipment when the 
Back-UPS is turned on and connected to AC power.
Battery backup outlets receive power from the Back-UPS for a limited period of time 
when a power outage, or brownout condition occurs.
Battery backup outlets provide protection from power surges or spikes.
Connect a computer, monitor and other peripheral devices to the outlets.
Surge Protection Outlets
Surge protection outlets provide protection to connected equipment when the 
Back-UPS is connected to AC power, and is switched on or off.
Surge protection outlets provide protection from power surges or spikes.
Connect a printer, scanner or other peripheral devices that do not need to remain on 
during power outages, or AC problems to the surge protection outlets.
Connect Network
The Back-UPS protects equipment connected to a 10/100 Base-T ethernet, from 
power surges when connected through the Back-UPS dataline protection jacks.
PowerChute™ Personal Edition Software
Overview
Use PowerChute Personal Edition software to configure the UPS settings.
Protect your computer and other equipment during a power outage. During a power 
outage, PowerChute will save any open files on your computer and safely shut it 
down. When power is restored, it will restart the computer.
Configure the UPS to use features such as power-saving outlets, shutdown 
configuration, and alarms.
Monitor the UPS for power usage and power events.
Note: PowerChute is only compatible with a Windows operating system. If you are 
using a Mac OSX, use the native shutdown feature to protect your system. See the 
documentation provided with your computer.
Installation
Use a USB cable to connect the Data port on the rear panel of the UPS to the USB port 
on your computer.
If the Back-UPS came with  CD into your computer and a PowerChute CD, insert the 
follow the on-screen instructions
If the Back-UPS did not come with a PowerChute CD, go to www.apc.com and 
download the software free of charge.
Turn On the Back-UPS
Press the POWER ON button located on the top of the Back-UPS. The Power On/
Replace Battery LED will illuminate and a single short beep will be audible to 
indicate that the Back-UPS is providing protection for connected equipment.
The Back-UPS battery charges fully during the first 24 hours while connected to AC 
power. The Back-UPS battery will charge while the Back-UPS is switched on or off 
and is connected to AC power. Do not expect full battery run capability during the 
initial charge time. 
If the red Building Wiring Fault LED located on the side of the Back-UPS 
illuminates, do not operate the Back-UPS. Have a qualified electrician correct the 
building wiring fault.
Warranty
The standard warranty is three (3) years from the date of purchase. Schneider Electric 
IT (SEIT) standard procedure is to replace the original unit with a factory 
reconditioned unit. Customers who must have the original unit back due to the 
assignment of asset tags and set depreciation schedules must declare such a need at 
first contact with an Schneider Electric IT (SEIT) Technical Support representative. 
SEIT will ship the replacement unit once the defective unit has been received by the 
repair department, or cross ship upon the receipt of a valid credit card number. The 
customer pays for shipping the unit to SEIT. SEIT pays ground freight transportation 
costs to ship the replacement unit to the customer.
Input
Voltage 120 Vac Nominal
Frequency 50/60 Hz + 3
Brownout Transfers 92 Vac Typical
Over-voltage Transfer 139 Vac Typical
Output
UPS Capacity 
(4 battery backup outlets)
BN575G: 575 VA, 345 W
Total Amperage (all outlets) 12 A (including UPS output)
Voltage - On Battery 115 Vac ± 8%
Frequency - On Battery 50/60 Hz + 1
Transfer Time 6 ms Typical, 10 ms maximum
Protection 
and 
Filtering
AC Surge Protection Full time, 340 Joules
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery
Type Sealed, maintenance-free, lead acid
BN575G: RBC110
Average Life 3 - 5 years depending on the number of 
discharge cycles and environmental 
temperature
Physical
Net Weight Replacement battery cartridge
BN575G: 12 lb (5.5 kg)
Dimensions 
Length x Width x Height
12 in x 7 in x 3 in
30 cm x 18 cm x 9 cm
Operating Temperature 32º F to 104º F (0º C to 40º C)
Storage Temperature 5º F to 113º F (–15º C to 45º C)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
 Press the battery compartment cover 
release tab located on the rear side of the 
unit. Slide the battery cover off.
 Connect the battery cable securely to the 
battery terminal.
 Reinstall the battery compartment cover. 
Be sure that the release tab locks into place.
bu075c
B
ack-U P
S 
bu064c
bu065c
bu066c
bu202a
Back-UPS 
Battery Backup +  Surge Protection 
Surge Protection 
bu201a
CAUTION-Refer to bottom
of unit for safety markings.
Circuit
Breaker
Building
Wiring Fault
PowerChute
USB Port
Network
Out
Push to
Reset
Network
In
User Manual Back-UPS™ BN575G
Produkspesifikasjoner
| Merke: | Apc | 
| Kategori: | UPS | 
| Modell: | Back-UPS BN575G | 
Trenger du hjelp?
Hvis du trenger hjelp med Apc Back-UPS BN575G still et spørsmål nedenfor, og andre brukere vil svare deg
UPS Apc Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            UPS Manualer
- Teltonika
- Middle Atlantic
- PowerWalker
- Conceptronic
- Phoenix Contact
- Tripp Lite
- Equip
- V7
- Hikvision
- FSP/Fortron
- Jung
- Salicru
- Block
- Online USV
- LevelOne
Nyeste UPS Manualer
                        
                         31 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         5 Mars 2025
                        
                    
                                                            
                        
                         5 Mars 2025
                        
                    
                                                            
                        
                         22 Februar 2025
                        
                    
                                                            
                        
                         21 Februar 2025
                        
                    
                                                            
                        
                         19 Februar 2025
                        
                    
                                                            
                        
                         30 Januar 2025
                        
                    
                                                            
                        
                         29 Januar 2025
                        
                    
                                                            
                        
                         29 Januar 2025