1
READ AND SAVE 
THESE INSTRUCTIONS
MODELS 120, 124 & 128
REGISTER HEATERS
MODELOS 120, 124 Y 128
CALENTADORES DE REJILLA
LEA Y CONSERVE 
ESTAS INSTRUCCIONES
WARNING
1.  ALL ELECTRICAL WORK MUST BE DONE IN ACCOR-
DANCE WITH LOCAL OR NATIONAL ELECTRICAL 
CODE AS APPLICABLE. FOR SAFETY, THIS PROD-
UCT MUST BE GROUNDED. IF YOU ARE UNFAMIL-
IAR WITH METHODS OF INSTALLING ELECTRICAL 
WIRING, SECURE THE SERVICES OF A QUALIFIED 
ELECTRICIAN.
2.  WHEN WIRING, SERVICING OR CLEANING THIS 
UNIT, TURN OFF POWER AND LOCK OUT SERVICE 
PANEL. FAILURE TO DO SO COULD ALLOW OTHERS 
OR THERMOSTAT TO TURN ON POWER UNEX-
PECTEDLY WHICH MAY CAUSE FATAL ELECTRICAL 
SHOCK.
3.  To avoid electrical shock:
•  DO NOT install unit in a tub or shower enclosure or 
any location where it may come in contact with water.
•  NEVER place a switch where it can be reached from 
a tub or shower.
4.  DO NOT install this unit in an area where chemicals or 
other flammables are stored or used. Explosion and fire 
may result.
CAUTION
1.  This product may ONLY be installed horizontally in a wall. 
DO NOT MOUNT IN ANY OTHER POSITION.
2.  Install heater at least 6" from floor or any adjacent vertical 
surface.
3.  DO NOT locate heater behind a door, furniture, drapes, 
etc., where the air flow to the unit would be restricted.
4.  Provide heater with an appropriately-rated electrical 
circuit to prevent tripped breakers or blown fuses (See 
chart below.)
5.  DO NOT CONNECT HEATER TO DIMMER SWITCH 
OR SPEED CONTROL.
6.  To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, 
etc., off power unit.
7.  Please read specification label on product for further 
information and requirements.
PLANNING
This heater is intended to be used to supply supplemental 
heat from a wall location in new or existing construction.
The heater can be operated using the Broan Model 86 
Line-Voltage Thermostat from a wall location. Purchase the 
control separately.
Plan to supply the heater with proper line voltage and ap-
propriate power cable.
NOTE: Power can be tapped from a nearby circuit depend-
ing on the heater wattage required and the amperage rating 
of the circuit.
Heater can be converted to half-wattage to avoid overload-
ing such circuits.
The table below lists the ratings for each model.
INSTALLER:  Leave This Manual With The Homeowner.  HOMEOWNER:  Use and Care Information on Page 3. 
INSTALADOR: Deje este manual con el dueño de casa.  DUEÑO DE CASA: Información del uso y mantenimiento en la página 3.
FIG. 1
DRYWALL/ 
PARED DE 
YESO
GRILLE/ 
REJILLA
WALL 
STUD/ 
VIGA DE 
LA PARED
HEATER 
HOUSING/ 
CAJA DEL 
CALENTA-
DOR
POWER 
CABLE/ 
CABLE 
DE EN-
ERGIA 
ADVERTENCIA
1.  TODO EL TRABAJO ELECTRICO DEBE REALIZARSE 
DE ACUERDO CON LOS CODIGOS ELECTRICOS 
LOCALES Y/O NACIONALES CORRESPONDIENTES. 
PARA SU SEGURIDAD, ESTE PRODUCTO DEBE 
SER CONECTADO A TIERRA. SI USTED NO ESTA 
FAMILIARIZADO CON LOS METODOS DE INSTALACION 
DEL CABLEADO ELECTRICO, OBTENGA LOS 
SERVICIOS DE UN ELECTRICISTA COMPETENTE.
2.  AL HACER EL CABLEADO, LIMPIEZA O DAR SERVICIO 
A ESTA UNIDAD, DESCONECTE LA POTENCIA Y 
ASEGURE EL PANEL DE SERVICIO. EL NO HACERLO 
PUEDE HACER POSIBLE QUE OTRAS PERSONAS O 
EL TERMOSTATO ACTIVE LA ENERGIA EN FORMA 
INESPERADA, LO QUE PUEDE CAUSAR UN GOPE 
ELECTRICO MORTAL.
3.  Para evitar descarga eléctrica:
*  NO instale la unidad en una bañera o recinto de ducha, 
ni en ningún lugar donde pueda entrar en contacto con 
el agua.
*  NUNCA coloque un interruptor en un lugar que pueda 
ser alcanzado desde una bañera o ducha.
4.  NO instale esta unidad en un área donde se almacenen o 
usen productos químicos u otros productos inflamables. De 
lo contrario, pueden producirse explosiones e incendios.
CUIDADO
1.  Este producto SOLAMENTE se puede instalar horizontal-
mente en una pared. NO LO MONTE EN NINGUNA OTRA 
POSICION.
2.  Instale el calentador por lo menos a 15,24 cm (6 pulg.) de 
distancia del piso o de alguna superficie vertical adyacente.
3.  NO COLOQUE el calentador detrás de una puerta, 
muebles, cortinas, etc., donde el flujo de aire a la unidad 
se encuentre restringido.
4.  Proporcione un circuito eléctrico de capacidad nominal al 
calentador, a fin de impedir la desconexión de disyuntores 
o quemado de fusibles. (Véase el diagrama abajo).
5.  NO CONECTE EL CALENTADOR A UN VARIADOR DE 
LUZ O UN CONTROL DE VELOCIDAD.
6.  Para evitar daños al cojinete del motor e impulsores 
ruidosos y/o desequilibrados, mantenga la unidad de 
energía alejada de rocíos de yeso, polvo de construcción, 
etc.
7.  Para más información y requisitos, lea la etiqueta de 
especificación sobre el producto.
PLANIFICACION
Este calentador p1-ha sido diseñado para proporcionar calefacción adi-
cional desde una pared en una construcción nueva o una p1-ya existente.
El calentador se puede poner en funcionamiento desde una pared 
usando el termostato de tensión de línea Broan Modelo 86. Adquiera 
los controles en forma separada.
Planifique proporcionar al calentador la tensión de línea y cable de 
energía eléctrica apropiados.
NOTA: La energía se puede tomar de un circuito cercano, lo que 
dependerá del vatiaje requerido del calentador y amperaje nominal 
del circuito.
El calentador se puede convertir a mitad de vatiaje para evitar sobre-
cargar dichos circuitos.
IMPORTANT INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE 
INSTALLING OR USING THIS  HEATER.
To reduce the risk of fire, electric shock, or injury to persons, 
observe the following:
1.  Use this unit only in the manner intended by the manufacturer. If 
you have questions, contact the manufacturer at the address or 
telephone number listed in the warranty.
2.  Before servicing or cleaning unit, switch power off at service 
panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.
3.  Installation work and electrical wiring must be done by a 
qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction codes and 
standards.
4.  When cutting or drilling into wall or ceiling, do not damage 
electrical wiring and other hidden utilities.
5.  This heater is hot when in use. To avoid burns, do not let bare 
skin touch hot surfaces. Keep combustible materials, such as 
furniture, pillows, bedding, papers, clothes, etc. and curtains at 
least 3 feet (0.9 m) from the front of the heater.
6.  Extreme caution is necessary when any heater is used by 
or near children or invalids and whenever the heater is left 
operating and unattended.
7.  Do not operate any heater after it malfunctions. Disconnect 
power at service panel and have heater inspected by a reputable 
electrician before reusing.
8.  Do not use outdoors.
9.  To disconnect heater, turn controls to off, and turn off power 
to heater circuit at main disconnect panel (or operate internal 
disconnect switch, if provided).
10. Do not insert or allow foreign objects to enter any ventilation or 
exhaust opening, as this may cause an electric shock or fire, or 
damage the heater.
11.  To prevent a possible fire, do not block air intakes or exhaust in 
any manner.
12. A heater has hot and arcing or sparking parts inside. Do not use 
it in areas where gasoline, paint, or flammable vapors or liquids 
are used or stored.
13. Use this heater only as described in this 
manual. Any other use not recommended by the 
manufacturer may cause fire, electric shock, or 
injury to persons.
14. Install heater at least 6 inches from floor or any 
adjacent wall.
15. To avoid electrical shock: Do not install unit in a 
tub or shower enclosure or any location where 
it may come in contact with water. Never place 
a switch where it can be reached from a tub or 
shower.
16. This product may ONLY be installed horizontally 
in a wall. Do not mount in any other position.
17. Do not connect heater to dimmer switch or 
speed control.
18. This product must be grounded.
SAVE THESE INSTRUCTIONS
INSTRUCCIONES IMPORTANTES
LEA TODAS LAS INSTRUCCIONES ANTES DE 
INSTALAR O USAR ESTE CALENTADOR.
Para reducir el riesgo de incendios, descargas eléctricas o lesiones 
personales, observe las siguientes precauciones:
1.  Use la unidad solo de la manera indicada por el fabricante. Si tiene 
preguntas, comuníquese con el fabricante a la dirección o al número 
telefónico que se incluye en la garantía.
2.  Antes de dar servicio a la unidad o de limpiarla, interrumpa el suministro 
eléctrico en el panel de servicio y bloquee los medios de desconexión 
del servicio para evitar que la electricidad se reanude accidentalmente. 
Cuando no sea posible bloquear los medios de desconexión del servicio, 
fije firmemente una señal de advertencia (como una etiqueta) en un 
lugar visible del panel de servicio.
3.  El trabajo de instalación y el cableado eléctrico deben estar a cargo 
de personal capacitado, de acuerdo con todos los códigos y normas 
correspondientes, incluidos los códigos y normas de construcción 
específicos sobre protección contra incendios.
4.  Al cortar o perforar a través de la pared o del cielo raso, tenga cuidado 
de no dañar el cableado eléctrico ni otros servicios ocultos.
5.  Este calentador se calienta cuando se usa. Para evitar quemaduras, 
no deje que la piel desnuda toque las superficies calientes. Mantenga 
materiales combustibles como muebles, almohadas, ropa de cama, 
papeles, ropa, etc., así como las cortinas, por lo menos a 3 pies (0.9 
m) de la parte delantera del calentador.
6.  Es necesario tener extremo cuidado cuando se use un calentador cerca 
de niños o personas inválidas, y siempre que el calentador se deje 
funcionando y sin atención.
7.  No haga funcionar ningún calentador después de que presente una 
falla. Desconecte la energía eléctrica en el panel de servicio y pida que 
un electricista acreditado inspeccione el calentador antes de volverlo a 
usar.
8.  No lo use en exteriores.
9.  Para desconectar el calentador, mueva los controles a la posición de 
apagado y desconecte la energía eléctrica al circuito del calentador en 
el panel de desconexión principal (o active el interruptor de desconexión 
interna, si existe).
10. No inserte ni permita que objetos extraños entren en la abertura de 
ventilación o de escape, pues esto puede ocasionar una descarga 
eléctrica, un incendio o daños al calentador.
11. Para prevenir un posible incendio, no bloquee la 
entrada o salida del aire de ninguna manera.
12. El calentador tiene piezas calientes y que pueden 
generar arcos eléctricos o chispas en el interior. No 
lo use en áreas donde se use o almacene gasolina, 
pintura o vapores o líquidos flamables.
13. Use este calentador solamente como se describe en 
este manual. Cualquier otro uso no recomendado 
por el fabricante puede ocasionar un incendio, una 
descarga eléctrica o lesiones a personas.
14. Instale el calentador por lo menos 6 pulg. desde el 
piso o cualquier pared adyacente.
15. Para evitar golpe eléctrico: No instale la unidad en 
una bañera o recinto de ducha. Nunca coloque un 
interruptor en un lugar que pueda ser alcanzado 
desde una bañera o ducha.
16. Este producto SOLAMENTE se puede instalar en 
una pared. No lo monte en ninguna otra posicion.
17. No conecte el calentador a un variador de luz o 
control de velocidad.
18. Este producto debe estar conectado a tierra.
GUARDE ESTAS INSTRUCCIONES
Produkspesifikasjoner
| Merke: | Broan | 
| Kategori: | Varmeapparat | 
| Modell: | 124 | 
Trenger du hjelp?
Hvis du trenger hjelp med Broan 124 still et spørsmål nedenfor, og andre brukere vil svare deg
Varmeapparat Broan Manualer
                        
                         19 Februar 2025
                        
                    
                                                            
                        
                         25 Januar 2025
                        
                    
                                                            
                        
                         25 Januar 2025
                        
                    
                                                            
                        
                         25 Januar 2025
                        
                    
                                                            
                        
                         25 Januar 2025
                        
                    
                                                            
                        
                         24 Januar 2025
                        
                    
                                                            
                        
                         21 Januar 2025
                        
                    
                                                            
                        
                         21 Januar 2025
                        
                    
                                                            
                        
                         21 Januar 2025
                        
                    
                                                            
                        
                         21 Januar 2025
                        
                    
                                                            Varmeapparat Manualer
- Fire Sense
- Astralpool
- Supra
- Essentiel B
- Delonghi
- Ambiano
- Big Ass Fans
- Igenix
- Teesa
- Kambrook
- Gorenje
- Rinnai
- Listo
- Ryobi
- Argoclima
Nyeste Varmeapparat Manualer
                        
                         4 April 2025
                        
                    
                                                            
                        
                         30 Mars 2025
                        
                    
                                                            
                        
                         30 Mars 2025
                        
                    
                                                            
                        
                         30 Mars 2025
                        
                    
                                                            
                        
                         30 Mars 2025
                        
                    
                                                            
                        
                         27 Mars 2025
                        
                    
                                                            
                        
                         27 Mars 2025
                        
                    
                                                            
                        
                         27 Mars 2025
                        
                    
                                                            
                        
                         27 Mars 2025
                        
                    
                                                            
                        
                         27 Mars 2025