CyberPower BR1200ELCD Bruksanvisning
                    CyberPower
                    
                    UPS
                    
                    BR1200ELCD
                
                                
                
                
                                
                Les nedenfor 📖 manual på norsk for CyberPower BR1200ELCD (2 sider) i kategorien UPS. Denne guiden var nyttig for 15 personer og ble vurdert med 4.7 stjerner i gjennomsnitt av 8 brukere
                        Side 1/2
                    
                    
                    
BR700ELCD / BR1000ELCD / BR1200ELCD 
User’s Manual 
  K01-C000108-03
This manual contains important instructions that should be followed during installation and maintenance of 
the UPS and batteries. Please read and follow all instructions carefully during installation and operation of 
the unit. Read this manual thoroughly before attempting to unpack, install, or operate. 
CAUTION! The UPS must be connected to a grounded AC power outlet with fuse or circuit breaker 
protection. DO NOT plug the UPS into an outlet that is not grounded. If you need to de-energize this 
equipment, turn off and unplug the UPS. 
CAUTION! DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! CyberPower Systems does 
not sell products for life support or medical applications.   use in any circumstance that would affect DO NOT
the operation or safety of any life support equipment, with any medical applications, or patient care. 
CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is 
disconnected. 
CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor 
area, free of conductive contaminants. (Please see specifications for acceptable temperature and humidity 
range). 
CAUTION! To reduce the risk of electric shock, do not remove the cover, except to service the battery. There 
are no user serviceable parts inside, except for the battery. 
CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before 
servicing the battery or installing a computer component. 
CAUTION! DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire, do not use with or near 
aquariums. Condensation from the aquarium can come in contact with metal electrical contacts and cause 
the machine to short out. 
CAUTION! DO NOT USE WITH LASER PRINTERS! The power demands of laser printers are too large for 
a UPS. 
UNPACKING 
The box should contain the following: 
(1) UPS Unit x 1; (2) Phone Line x 1; (3) USB Cable x 1; (4) User Manual x 1; (5) Cable Collector x 1; 
(6) Warranty Card x 1; 
*PowerPanel® Personal Edition software is available on our website. Please visit www.cyberpower.com 
and 
go to the Software Section for free download. 
OVERVIEW 
The BR700ELCD/ BR1000ELCD/ BR1200ELCD provides automatic voltage regulation for inconsistent utility 
power. The BR700ELCD/ BR1000ELCD/ BR1200ELCD features 125 Joules of surge protection, and 
provides battery backup during power outages. The BR700ELCD/ BR1000ELCD/ BR1200ELCD ensures 
consistent power to your computer system and its included software will automatically save your open files 
and shutdown your computer system during a utility power loss. 
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 
1.  Make sure that the total Volt-Amp (VA) requirements of your computer, monitor, and peripheral 
equipment does not exceed 700VA/1000VA/1200VA.     
2.  Ensure that the equipment plugged into the battery power-supplied/surge outlets does not exceed the 
UPS unit's rated capacity (700VA/420W forBR700ELCD,1000VA/600W for BR1000ELCD, 
1200VA/720W for BR1200ELCD). If the rated unit capacities are exceeded, an overload condition may 
occur and cause the UPS unit to shut down and the circuit breaker to trip. 
HARDWARE INSTALLATION GUIDE 
1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 
hours is recommended to ensure that the battery's maximum charge capacity is achieved. Charge loss 
may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC 
outlet. The unit will charge in both the on and off position. 
2. If you will use the software, connect the USB cable to the USB port on the UPS. 
3. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data 
storage device (Zip drive, Jazz drive, Tape drive, etc. into the battery power supplied outlets. DO NOT 
plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device 
into the UPS. The power demands of these devices will overload and possibly damage the unit. 
4. To protect a fax, telephone, modem line or network cable, connect a telephone cable or network cable 
from the wall jack outlet to the IN jack of the UPS. Then connect a telephone cable or network cable from 
the OUT jack on the UPS to the modem, computer, telephone, fax machine, or network device. 
5. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is 
protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. 
air conditioner, refrigerator, copier, etc.) Avoid using extension cords. 
6. Depress the power switch to turn the unit on. The power on indicator light will illuminate and the unit will 
"beep". 
7. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, 
turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 
10 seconds. Make sure the circuit breaker is depressed and then turn the UPS on. 
8. Your UPS is equipped with an auto-charge feature. When the UPS is plugged into an AC outlet, the 
battery will automatically recharge. 
9. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 
10. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the 
battery every three months to ensure battery life. 
DESCRIPTION
1.  Power Switch 
Press the switch for two seconds to turn the UPS ON or OFF. 
2.  LCD Display Selected Switch 
The switch can be used to select the LCD display contents including Input Voltage, Output Voltage and 
Estimated Run Time. The toggle frequency is set to one time per second. Holding the switch for more than 
two seconds while running on battery will silence the buzzer. 
3.  LCD Display 
High resolution and intelligent LCD display shows all the UPS information with icons and messages. For 
more information please review the “Definitions for Illuminated LCD Indicators” section. 
4.  Communication Protection Ports RJ11/RJ45 
Communication protection ports will protect any standard modem, fax, telephone line, or network cable from 
surge and spikes. 
5.  AC Outlets 
The UPS provides 4 outlets for connected equipment to insure temporary uninterrupted operation during a 
power failure and against surges and spikes and another 4 outlets against surges and spikes only. 
6.  USB Charger Port 
The UPS provides charging for external equipment via this port. 
7.  Cable Collector 
Collect the cables connected from the AC outlets in the cable collector. 
8.  Led Indicators 
The power on LED lights up when the UPS is ON. 
9.  USB Port To PC 
This port allows connection and communication from the USB port on the computer to the UPS unit. The 
UPS communicates its status to the PowerPanel® Personal Edition software. 
10. Input Circuit Breaker 
The Circuit Breaker provides optimal overload protection. 
11. Input Power Cord 
Connect to utility power 
Model   BR700ELCD-UK  BR1000ELCD-UK  BR1200ELCD-UK 
Capacity (VA)  700VA  1000VA  1200VA 
Capacity (Watts)  420W  600W  720W 
Input 
Input Voltage Range  165-290Vac 
Frequency Range  47~63Hz (Auto Sensing) 
AVR Function  Boost @ 200+/-10V 
Output 
On Battery Output Voltage  Simulated Sine Wave at 230Vac +/-10% 
On Battery Output Frequency  50/60Hz +/-1% 
Transfer Time  4ms Typical 
Overload Protection 
On Utility: Circuit Breaker and Internal Current Limiting 
On Battery: Internal Current Limiting 
Surge Protection 
Lightning / Surge Protection  Yes 
Network/ Phone/ Fax/ Modem 
Protection 
RJ11/RJ45 (One In/ One Out) 
Operating Temperature  +32F to 104F ( 0C to 40C ) 
Physical 
Total # of UPS outlets  6 (3 for battery backup and surge, 3 for surge only) 
Dimensions (WxHxD) (mm)  166x 118x288 
Weight (kg)  5.3  6.5  8.2 
Wall-mounted Distance(mm)  163 
Battery 
Sealed Maintenance Free 
Lead Acid Battery 
RBP0083 RBP0006 RBP0063 x 1   x 1   x 2 
Typical Recharge Time  8 hours 
User Replaceable  Yes 
Status Indicators 
Indicators  Power On, LCD Display 
Audible Alarms  On Battery, Low Battery, Overload 
Communication 
PowerPanel
®
 Personal Edition 
Software 
Windows 8/7/Vista/XP/2000,Server 2012/2008/2003, Linux 
Management 
Auto-Charger  Yes 
Auto-Restart  Yes 
USB interface  Yes 
TECHNICAL SPECIFICATIONS 
BASIC OPERATION 
INSTALLING YOUR UPS SYSTEM 
IMPORTANT SAFETY INSTRUCTIONS 
Produkspesifikasjoner
| Merke: | CyberPower | 
| Kategori: | UPS | 
| Modell: | BR1200ELCD | 
Trenger du hjelp?
Hvis du trenger hjelp med CyberPower BR1200ELCD still et spørsmål nedenfor, og andre brukere vil svare deg
UPS CyberPower Manualer
                        
                         29 Januar 2025
                        
                    
                                                            
                        
                         28 Januar 2025
                        
                    
                                                            
                        
                         28 Januar 2025
                        
                    
                                                            
                        
                         28 Januar 2025
                        
                    
                                                            
                        
                         28 Januar 2025
                        
                    
                                                            
                        
                         28 Januar 2025
                        
                    
                                                            
                        
                         16 Januar 2025
                        
                    
                                                            
                        
                         13 Januar 2025
                        
                    
                                                            
                        
                         13 Januar 2025
                        
                    
                                                            
                        
                         4 Januar 2025
                        
                    
                                                            UPS Manualer
- Block
- IKEA
- Online USV
- Conceptronic
- AEG
- FSP/Fortron
- Tripp Lite
- Equip
- Hikvision
- Teltonika
- Apc
- Jung
- LevelOne
- Phoenix Contact
- PowerWalker
Nyeste UPS Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         3 April 2025