CyberPower CP500PFCRM1U Bruksanvisning
                    CyberPower
                    
                    UPS
                    
                    CP500PFCRM1U
                
                                
                
                
                                
                Les nedenfor 📖 manual på norsk for CyberPower CP500PFCRM1U (2 sider) i kategorien UPS. Denne guiden var nyttig for 20 personer og ble vurdert med 3.5 stjerner i gjennomsnitt av 10.5 brukere
                        Side 1/2
                    
                    
                    
YOUR ULTIMATE ALLY IN POWER 
CP500PFCRM1U / CP700PFCRM1U 
USER MANUAL 
FEATURES
1 . LCD module display 
2 . Power On Indicator 
1  2  3  4 
3 . Power Switch 
4 . LCD Function Selected Switch 
5 . Battery and Surge Protected Outlets 
6 . Full-Time Surge Protection Outlets 
5  6  7  8  9  10  11  12  13 
7 . SNMP/HTTP Network Slot 
8 . Communication Protection Ports RJ45 
9 . USB Port to PC 
10 . DB9 port 
1 1 . Circuit Breaker 
12 . AC Input 
13 . Electrical Wiring Fault Indicator (Red) 
PRODUCT REGISTRATION 
Thank you for purchasing this CyberPower product. Please take a few minutes to register your product at:  w.CyberP erSystems.com/Registration. ww ow
Registration certifies your product's warranty, confirms your ownership in the event of a product loss or theft and entitles you to free technical support. Register your product now to receive 
the benefits of CyberPower ownership. 
IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) 
This manual contains important instructions that should be foll ed during installation ow
and maintenance of the UPS and batteries. Please read and follow all instructions 
carefully during installation and operation of the unit. Read this manual thoroughly before 
attempting to unpack, install, or operate. 
CAUTION! To prevent the risk of fire or 
electric shock, install in a temperature 
and humidity controlled indoor area free 
of conductive contaminants. (Please see 
specifications for a eptable temperature cc
and humidity range). 
CAUTION! To reduce the risk of electric 
shock, do not rem e the c er. There are ov ov
no user serviceable parts inside except for 
the battery. 
CAUTION! Hazardous live parts inside can 
be energized by the battery even when the 
AC input p er is disconnected. ow
CAUTION! The UPS must be connected 
to an AC p er outlet with fuse or circuit ow
breaker protection. Do not plug into an 
outlet that is not grounded. If you need to 
de-energize this equipment, turn o° and 
unplug the unit. 
CAUTION! To avoid electric shock, turn 
o° the unit and unplug it from the AC 
power source before installing a computer 
component. 
CAUTION! Not for use in a computer 
room as defined in the Standard for the 
Protection of Electronic Computer/Data 
Processing Equipment, ANSI/NFPA 75. 
CAUTION! To reduce the risk of fire, 
connect only to a circuit provided with 
20 amperes maximum branch circuit over 
current protection in a ordance with the cc
National Electric Code, ANSI/NFPA  . 70
CAUTION! For PLUGGABLE EQUIPMENT, 
the socket-outlet shall be installed near the 
equipment and shall be easily accessible. 
DO NOT USE FOR LIFE SUPPORT  
EQUIPMENT!  CyberP er Systems does ow
not sell products for life support. DO NOT 
use in any circumstance that would a°ect 
operation and safety of life support  
equipment. 
CAUTION! DO NOT USE WITH OR NEAR 
AQUARIUMS! To reduce the risk of fire or 
electric shock, do not use with or near an 
aquarium. Condensation from the aquarium 
can cause the unit to short out. 
CAUTION! DO NOT USE THE UPS ON ANY 
TRANSPORTATION!  To reduce the risk of 
fire or electric shock, do not use the unit on 
an ran ta uch a ay t spor tion s s  irpl es an o h . r s ips
The e°ect of shock or vibration caused 
during transit and the damp environment 
can cause the unit to short out. 
CAUTION! DO NOT USE WITH LASER 
PRINTERS! The power demands of laser 
printers are too large for a UPS. 
CAUTION! To reduce the risk of electric 
shock, do not remove the c er, except to ov
service the battery. There are no serviceable 
parts inside, except for the battery.
WARNING
: This product can expose 
you to chemicals including Styrene, which 
is known to the State of California to cause 
cancer, and Bisphenol-A, which is known to 
the State of California to cause birth defects 
or other reproductive harm. For more 
information, go to  w.P65Warnings. .gov. ww ca
INSTALLING YOUR UPS SYSTEM 
UNPACKING 
Inspect the UPS upon receipt. The box 
should contain the following: 
(a) UPS unit 
(b) User’s manual 
(c) Rack mount brackets 
(d) USB A+B type cable 
*P erPanel® Business software is ow
available on our website. Please visit 
CyberPowerSystems.com and go to the 
Software Section for free download. 
OVERVIEW 
The CP500PFCRM1U / CP700PFCRM1U 
provides automatic voltage regulation 
to correct for inconsistent utility power. 
The CP500PFCRM1U / CP700PFCRM1U 
features 1150 Joules of surge protection, 
and provides battery backup during 
p er outages. The CP500PFCRM1U / ow
CP700PFCRM1U ensures consistent power 
to your computer system and its included 
software will automatically save your open 
files and shutdown your computer system 
during a utility power loss. 
HOW TO DETERMINE THE POWER 
REQUIREMENTS OF YOUR EQUIPMENT 
1.  Ensure that the equipment plugged into 
the UPS does not exceed the UPS unit’s 
rated capacity. If the rated capacities 
of the unit are exceeded, an overload 
condition may occur and cause the UPS 
unit to shut down or the circuit breaker 
to trip. 
2.  There are many factors that can 
a°ect the amount of power that your 
electronic equipment will require. For 
optimal system performance keep the 
load below 80% of the unit’s rated 
capacity. 
Cyber Power Systems (USA), Inc. 
AUTOMATIC VOLTAGE REGULATOR 
The CP500PFCRM1U/CP700PFCRM1U 
stabilizes inconsistent utility power. The 
incoming utility power may be damaging 
to important data files, but with Automatic 
Voltage Regulation, the computer will not 
experience damaging voltage levels. An 
Aut a Vom tic  oltage Regulator aut aom ti llca y 
increases low voltage to a consistent, 
computer safe 110v/120v. The unit’s 
p erful sealed lead-acid batteries will ow
provide p er only if the incoming voltage ow
drops below 100v. 
HARDWARE INSTALLATION GUIDE 
1.  Your new UPS may be used immediately 
upon receipt. However, after receiving 
a new UPS, to ensure the battery’s 
maximum charge capacity, it is 
recommended that you charge the 
battery for at least 8 hours. Your UPS is 
equipped with an auto-charge feature. 
When the UPS is plugged into an AC 
outlet, the battery will automatically 
charge whether the UPS is turned on or 
turned o°. 
2.  If you will use the software, connect the 
USB cable to the USB port on the UPS. 
3.  With the UPS unit turned o° and 
unplugged, connect your computer, 
monitor, and any other peripherals 
requiring battery backup into the 
battery power supplied outlets. Plug the 
other peripheral equipment (e.g. printer, 
scan r, speakers, etc.) into the full-time ne
surge protection outlets. DO NOT plug 
a laser printer, paper shredder, copier, 
space heater, vacuum cleaner, sump 
pump, or other large electrical device 
into the “Battery and Surge Protected 
Outlets”. The p er demands of these ow
devices will  erload and possibly ov
damage the unit. 
INSTALLING YOUR UPS SYSTEM - Continued 
HARDWARE INSTALLATION GUIDE 
4.  Plug the UPS into a 2 pole, 3 wire 
grounded receptacle (wall outlet). Make 
sure the wall branch outlet is protected 
by a fuse or circuit breaker and does 
not service equipment with large 
electrical demands ( g. air conditioner, e.
refrigerator, copier, etc.). The warranty 
prohibits the use of extension cords, 
outlet strips, and 
surge strips in 
conjunction with 
the UPS unit. 
5.  Press the power switch to turn the unit 
on. The Power On indicator light will 
illuminate green and the unit will “beep” 
twice. 
RACK INSTALLATION (OPTION) 
6.  If an overload is detected, an audible 
alarm will sound and the unit will emit 
one long beep. To correct this, turn the 
UPS o° and unplug at least one piece 
of equipment from the battery p er ow
supplied outlets. Make sure the circuit 
breaker is depressed and then turn the 
UPS on. 
7.  To maintain optimal battery charge, 
leave the UPS plugged into an AC outlet 
at all times. 
8.  To store the UPS for an extended period 
of time, c er it and store with the ov
battery fully charged. While in storage, 
rec rha ge t e bh attery ever hre months y t e 
to ensure optimal battery life. 
9.  Ensure the wall outlet and UPS are 
located near the equipment being 
attached for proper accessibility. 
1.  Use the provided pan head screws to attach the hanging brackets to the UPS. 
2.  Use the provided truss head screws to secure the UPS to your existing rack system. 
1.  2. 
REPLACING THE BATTERY 
Read and follow the important safety instructions before servicing the batteries. Visit 
CyberPower o˛cial 
website www.cyberpowersystems.com or contact your dealer for more information about 
replacement batteries. 
CAUTION! Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing 
the battery. Service the battery under the supervision of personnel knowledgeable of 
batteries and their precautions. 
CAUTION! When replacing batteries, replace with the same number of the following 
battery: CyberP er/RB0670X2 for CP500PFCRM1U and CyberP er/ RB0690X2 for ow ow
CP700PFCRM1U. See your dealer for replacement batteries. 
CAUTION! Risk of energy hazard, 12 V, 7 Ampere-hour battery for CP500PCFRM1U, 12V, 8 
Ampere-hour battery for CP700PCFRM1U. Before replacing batteries, rem e conductive ov
jewelry such as chains, wrist watches and rings. High energy through conductive materials 
could cause severe burns. 
CAUTION! Risk of explosion if battery is replaced by an incorrect type. Dispose of used 
batteries a ording to the instructions. cc
CA Th att ma rUTION!  e b ery  y p ese ct k.  o n e o et th  risk  f el ric cal sho D n e o atte s ot dispos f b rie
in a fire, the batteries may explode. Follow all local ordinances regarding proper disposal 
of batteries. 
1.  2. 
Remove the right-side of the faceplate.  Remove the three retaining screws on 
the cable protection cover. 
5.  6. 
Remove the retaining screw of the  Replace the new battery pack. 
battery tray. 
BASIC OPERATION 
1.  LCD module display 
LCD Screen shows all the UPS information 
with icons and messages. 
2.  Power On Indicator 
This LED is illuminated when the utility 
condition is no al and the UPS outlets are rm
providing p er, free of surges and spikes. ow
3.  Power Switch 
Master on/o° switch for equipment 
connected to the battery p er supplied ow
outlets. 
4.  LCD Function Selected Switch 
The switch can be used to select the LCD 
display contents Including input/output 
voltage and estimated run time, etc. 
5.  Battery and Surge Protected Outlets 
The unit has four battery powered/surge 
protec tl ts  r te ud o e fo c n te nt on ec d equipme
to ensure temporary uninterrupted 
operation of your equipment during a 
p er failure. (DO NOT plug a laser printer, ow
paper shredder, copier, space heater, 
vacuum cleaner, sump pump or other 
large electrical devices into the “Battery 
and Surge Protected Outlets”. The p er ow
demands of these devices may  erload ov
and damage the unit.) 
6.  Full-Time Surge Protection Outlets 
The unit has two surge protected outlets. 
7.  SNMP/HTTP Network Slot 
Rem e the c er panel to install an ov ov
optional RMCARD provides remote 
monitoring and management of your UPS 
over a network. 
8.  Communication Protection Ports RJ45 
Communication protection ports, bi-
directional, will protect a 10/100/1000 
ethernet connection. (RJ45). 
*Not for telecommunication (telephone) 
network. 
9.  USB Port to PC 
This port allows connection and 
communication from the USB port on 
the computer to the UPS unit. The UPS 
c icatommun es its statu tos   the P erPa l® ow ne
Business software. 
10. DB9 Port 
This port is used for connecting between 
the UPS and equipment designed to 
operate with  contact signals. 
11.  Circuit Breaker 
Located on the back of the UPS, the circuit 
breaker serves to provide overload and 
fault protection. Under normal operating 
conditions, the circuit breaker is depressed. 
12. AC Input 
Connect the AC Power cord to a properly 
wired and grounded outlet. 
13. Electrical Wiring Fault Indicator (Red) 
This LED indicator will illuminate to warn 
the user that a wiring problem exists, 
such as a bad ground, missed ground 
or reversed wiring. If this is illuminated, 
disconnect all electrical equipment from 
the outlet and have an electrician check 
to ensure the outlet is properly wired. 
The unit will not provide surge protection 
without being plugged into a grounded 
and properly wired wall outlet. 
CAUTION! Do not open or mutilate batteries. Released material is harmful to the skin and eyes. 
It may be toxic. 
CAUTION! A battery can present a risk of electrical shock and high short-circuit current. 
Contact with part of a grounded battery can result in electrical shock. The following 
precautions should be observed when working on batteries: 
1. Remove all watches, rings or other metal objects. 
2. Only use tools with insulated handles. 
3.  lay tools or other metal parts on top of battery or any battery terminals. DO NOT 
4. Wear rubber gloves and boots. 
5. Determine if the battery is inadvertently grounded. If inadvertently grounded, rem e ov
source of ground. 
CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK! The 
likelihood of such shock will be reduced if such grounds are removed during installation and 
maintenance (applicable to a UPS and a remote battery supply not having a grounded circuit). 
CAUTION! The used batteries are considered hazardous waste and must be disposed through 
recycling. 
Most retailers that sell lead-acid batteries collect used batteries for recycling, as required by 
local regulations. 
3. 
4. 
Remove the cable protective cover. 
Disconnect the black and red cables. 
7. 
Assemble the screws, cover, cable and front 
panel in the reverse sequence of ab e steps. ov
Recharge the unit for 8 hours to ensure the UPS 
performs expected runtime. 
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379 | CyberPowerSystems.com 
K01-0001050-00 
Produkspesifikasjoner
| Merke: | CyberPower | 
| Kategori: | UPS | 
| Modell: | CP500PFCRM1U | 
Trenger du hjelp?
Hvis du trenger hjelp med CyberPower CP500PFCRM1U still et spørsmål nedenfor, og andre brukere vil svare deg
UPS CyberPower Manualer
                        
                         29 Januar 2025
                        
                    
                                                            
                        
                         28 Januar 2025
                        
                    
                                                            
                        
                         28 Januar 2025
                        
                    
                                                            
                        
                         28 Januar 2025
                        
                    
                                                            
                        
                         28 Januar 2025
                        
                    
                                                            
                        
                         28 Januar 2025
                        
                    
                                                            
                        
                         16 Januar 2025
                        
                    
                                                            
                        
                         13 Januar 2025
                        
                    
                                                            
                        
                         13 Januar 2025
                        
                    
                                                            
                        
                         4 Januar 2025
                        
                    
                                                            UPS Manualer
- V7
- Xtreme
- Jung
- Phoenix Contact
- LevelOne
- Tripp Lite
- FSP/Fortron
- Equip
- Online USV
- IKEA
- Block
- Middle Atlantic
- AEG
- PowerWalker
- Conceptronic
Nyeste UPS Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         3 April 2025