Fujitsu ABTG18LVTA Bruksanvisning
Fujitsu
Air condition
ABTG18LVTA
Les nedenfor 📖 manual på norsk for Fujitsu ABTG18LVTA (21 sider) i kategorien Air condition. Denne guiden var nyttig for 3 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/21

HEAT & COOL MODEL
(REVERSE CYCLE)
AIR CONDITIONER
Floor/Ceiling Type
OPERATING MANUAL
KEEP THIS MANUAL FOR FUTURE REFERENCE
P/N9374379446

En-1
SAFETY PRECAUTIONS
● Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.
● The instructions in this section all relate to safety; be sure to maintain safe operating conditions.
● “DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:
● Do not attempt to install this air conditioner by yourself.
●
This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs.
● When moving, consult authorized service personnel for disconnection and installation of the air condi-
tioner.
● Do not become excessively chilled by staying for many hours in the direct cooling airfl ow.
● Do not insert fi ngers or objects into the outlet port or intake grilles.
●
Do not start and stop air conditioner operation by disconnecting the power supply cable and so on.
● Take care not to damage the power supply cable.
● In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical
breaker, and consult authorized service personnel.
● If the power supply cable of this appliance is damaged, it should only be replaced by the authorized
service personnel, since special purpose tools and specifi ed cable are required.
● In the event of the refrigerant leakage, be sure to keep it away from fi re or any fl ammables. (consult an
authorized service personnel)
● Provide occasional ventilation during use.
● Do not direct air fl ow at fi replaces or heating apparatus.
● Do not climb on, or place objects on, the air conditioner.
● Do not hang objects from the indoor unit.
● Do not set fl ower vases or water containers on top of air conditioners.
● Do not expose the air conditioner directly to water.
● Do not operate the air conditioner with wet hands.
● Do not pull power supply cable.
● Turn off power source when not using the unit for extended periods.
●
Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air fi lter.
● Connection valves become hot during Heating; handle with care.
● When restarting after a long period of disuse in the winter, turn the power switch on at least 12 hours
before starting the unit.
● Check the condition of the installation stand for damage.
● Do not place animals or plants in the direct path of the air fl ow.
● Do not drink the water drained from the air conditioner.
● Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art
works.
● Do not apply any heavy pressure to radiator fi ns.
● Operate only with air fi lters installed.
● Do not block or cover the intake grille and outlet port.
●
Ensure that any electronic equipment is at least 1 m away from either the indoor or outdoor units.
● Avoid installing the air conditioner near a fi replace or other heating apparatus.
● When installing the indoor and outdoor units, take precautions to prevent access by infants.
● Do not use infl ammable gases near the air conditioner.
● Install the drain hose so that it drains water properly.
● This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety. Children should be
supervised to ensure that they do not play with the appliance.
CAUTION!
WARNING!
CAUTION!
This mark indicates procedures which, if improperly performed, are most likely to
result in the death or serious injury to the user or service personnel.
This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user or service personnel.
This mark indicates procedures which, if improperly performed, might possibly re-
sult in personal harm to the user, or damage to property.
DANGER!
DANGER!
CONTENTS
SAFETY PRECAUTIONS ........................................... 1
FEATURES AND FUNCTIONS .................................. 2
NAME OF PARTS ...................................................... 3
PREPARATION .......................................................... 5
OPERATION ............................................................... 6
TIMER OPERATION .................................................. 8
SLEEP TIMER OPERATION ...................................... 9
MANUAL AUTO OPERATION .................................... 9
ADJUSTING THE DIRECTION OF AIR CIRCULATION
... 10
SWING OPERATION ................................................11
ECONOMY OPERATION ..........................................11
10 °C HEAT OPERATION ........................................ 12
SELECTING THE REMOTE
CONTROLLER SIGNAL CODE ............................... 12
CLEANING AND CARE ............................................ 13
TROUBLESHOOTING ............................................. 14
OPERATING TIPS .................................................... 15

En-2
FEATURES AND FUNCTIONS
■ Energy saving and Comfortable function
INVERTER
At the start of operation, large amount of power is used to
bring the room quickly to the desired temperature. Afterwards,
the unit automatically switches to a low power setting for eco-
nomic and comfortable operation.
ECONOMY OPERATION
When ECONOMY operation mode is operated, the room tem-
perature will be little higher than the set-temp under cooling
mode and lower than set-temp under heating mode. Therefore,
the ECONOMY mode is able to save more energy than other
normal mode.
OMNI-DIRECTIONAL AIR FLOW
(SWING OPERATION)
3-dimensional control over air direction swing is possible
through dual use of both an UP/DOWN air direction swing and
RIGHT/LEFT air direction swing. Since UP/DOWN air direction
fl aps operate automatically according to the operating mode of
the unit, it is possible to set air direction based on the operat-
ing mode.
SUPER QUIET OPERATION
When the FAN button is used to select QUIET, the indoor unit
begins super quiet operation; the indoor unit’s airflow is re-
duced to produce quieter operation.
AUTO CHANGEOVER
The operation mode (cooling, dry, heating) is switched auto-
matically to maintain the set temperature, and the temperature
is kept constant at all times.
10°C HEAT OPERATION
The room temperature can be maintained at 10°C so as to
pre-vent the room temperature from falling too far.
■ Convenient function
PROGRAM TIMER
The program timer allows you to integrate OFF timer and ON
timer operations in a single sequence. The sequence can in-
volve 1 transition from OFF timer to ON timer, or from ON
timer to OFF timer, within a 24 hour period.
SLEEP TIMER
When the SLEEP timer button is pressed during Heating
mode, the air conditioner’s thermostat setting is gradually
lowered during the pe-riod of operation; during Cooling or Dry
mode, the thermostat setting is gradually raised during the
period of operation. When the set time is reached, the unit au-
tomatically turns off.
■ Clean function
REMOVABLE INTAKE GRILLE
The indoor unit’s intake grille can be removed for easy clean-
ing and maintenance.
MILDEW-RESISTANT FILTER
The AIR FILTER has been treated to resist mildew growth,
thus allowing cleaner use and easier care.
■ Remote controller
WIRELESS REMOTE CONTROLLER
The wireless remote controller allows convenient control of air
conditioner operation.
WIRED REMOTE CONTROLLER (OPTION)
The optional wired remote controller can be used.
When you use remote controller, there are following different-
points as compared with using wireless remote controller.
[The additional functions for wired ones]
• Weekly timer
• Temperature set back timer
And you can use both wired and wireless remote controller si-
multaneously.
(But function is limited)
When the restricted functions on the remote controller are
used, beeping sound will be heard, OPERATION, TIMER and
the 3rd lamp of the indoor unit will fl ash.
[The restricted functions for wireless ones]
• SLEEP TIMER
• TIMER (ON timer, OFF timer and Program timer)
• 10°C HEAT OPERATION
Produkspesifikasjoner
Merke: | Fujitsu |
Kategori: | Air condition |
Modell: | ABTG18LVTA |
Trenger du hjelp?
Hvis du trenger hjelp med Fujitsu ABTG18LVTA still et spørsmål nedenfor, og andre brukere vil svare deg
Air condition Fujitsu Manualer

3 April 2025

30 Mars 2025

25 Februar 2025

25 Februar 2025

25 Februar 2025

25 Februar 2025

25 Februar 2025

22 Januar 2025

22 Januar 2025

22 Januar 2025
Air condition Manualer
- Air condition Thomson
- Air condition Amana
- Air condition Whirlpool
- Air condition Haier
- Air condition NewAir
- Air condition LG
- Air condition Bosch
- Air condition BEKO
- Air condition Hisense
- Air condition Koldfront
- Air condition Arcelik
- Air condition Danby
- Air condition Gree
- Air condition TCL
- Air condition Hotpoint
- Air condition Cecotec
- Air condition Samsung
- Air condition Noveen
- Air condition Delonghi
- Air condition Comfee
- Air condition Kogan
- Air condition SereneLife
- Air condition Create
- Air condition Furrion
- Air condition Midea
- Air condition Sauber
- Air condition Candy
- Air condition Carson
- Air condition Orbegozo
- Air condition Panasonic
- Air condition Olimpia Splendid
- Air condition Vox
- Air condition Westinghouse
- Air condition Sencor
- Air condition Orava
- Air condition Mistral
- Air condition Khind
- Air condition CyberPower
- Air condition Frigidaire
- Air condition Dimplex
- Air condition Bimar
- Air condition Whynter
- Air condition GE
- Air condition Hitachi
- Air condition Hyundai
- Air condition VänEE
- Air condition Ausclimate
- Air condition Infiniton
- Air condition Ufesa
- Air condition Lavorwash
- Air condition Omega Altise
- Air condition Daikin
- Air condition Be Cool
- Air condition Blaupunkt
- Air condition Einhell
- Air condition Avidsen
- Air condition Mitsubishi
- Air condition Friedrich
- Air condition Tristar
- Air condition Eldom
- Air condition Elba
- Air condition Philco
- Air condition REMKO
- Air condition Vivax
- Air condition Black And Decker
- Air condition Ozito
- Air condition Toshiba
- Air condition Wilfa
- Air condition Heinner
- Air condition SEEGER
- Air condition Meireles
- Air condition IFB
- Air condition Profilo
- Air condition Middle Atlantic
- Air condition Duracraft
- Air condition Home Electric
- Air condition Milectric
- Air condition LERAN
- Air condition Perfect Aire
- Air condition Argoclima
- Air condition Svan
- Air condition ARCTIC WIND
- Air condition Trisa
- Air condition Daizuki
- Air condition Mayer
- Air condition HTW
- Air condition Be Quiet!
- Air condition Broan
- Air condition BOSFOR
- Air condition KDK
- Air condition Aconatic
- Air condition AireMax
- Air condition Profile
- Air condition Keystone
- Air condition Honeywell
- Air condition Theben
- Air condition Carrier
- Air condition Ravanson
- Air condition Yamazen
- Air condition ActronAir
- Air condition Orima
- Air condition Woods
- Air condition Aspes
- Air condition Soler & Palau
- Air condition Bavaria
- Air condition Dantherm
- Air condition Sôlt
- Air condition Daitsu
- Air condition Fuave
- Air condition Proklima
- Air condition Universal Blue
- Air condition Rinnai
- Air condition Symphony
- Air condition Kelvinator
- Air condition Premium
- Air condition Corona
- Air condition Krone
- Air condition Royal Sovereign
- Air condition Gutfels
- Air condition Duux
- Air condition GoldAir
- Air condition Heller
- Air condition Teco
- Air condition Magnavox
- Air condition SHE
- Air condition Cool-Space
- Air condition KuulAire
- Air condition BLUEPALM
- Air condition Essentiel B
- Air condition BISWIND
- Air condition Igenix
- Air condition Fuji Electric
- Air condition Sheffield
- Air condition General
- Air condition Hoffman
Nyeste Air condition Manualer

10 April 2025

10 April 2025

10 April 2025

10 April 2025

10 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025

9 April 2025