User Manual  
Pressure Gauge PCE-DMM 70 / PCE-DMM 60 
1.1 Information on the operating manual 
This  operating  manual  contains  important  information  on  proper 
usage of the device. Read this operating manual carefully before 
installing and starting up the pressure measuring device. 
Adhere  to  the safety  notes  and  operating instructions  which  are 
given in the operating manual. Additionally applicable regulations 
regarding  occupational  safety,  accident  prevention  as  well  as 
national  installation  standards  and  engineering  rules  must  be 
complied with! 
This operating manual is part of  the device and  must be kept at 
a,  for  the  personnel  always  accessible  location,  close  to  the 
installation position of the device. 
This  operating  manual  is  copyrighted.  The  contents  of  this 
operating  manual  reect  the  version  available  at  the  time  of 
printing.  It  has  been  issued  to  our  best  knowledge  and  belief. 
However,  errors  may  have  occurred.  For  incorrect  statements 
and  their  consequences,  liability  cannot  be  assumed  by  PCE 
Instruments. 
– –Technical modications reserved   
1.2 Symbols used 
DANGER!    Dangerous  situation,  which  may  result  in –
serious or fatal injuries 
WARNING!    Potentially  dangerous  situation,  which  may –
result in fatal or serious injuries 
CAUTION!    Potentially  dangerous  situation,  which  may –
result in minor injuries 
!CAUTION!    Potentially  dangerous  situation,  which  may –
result in damage of objects 
NOTE    Tips  and  information  for  the  user  to  ensure  good–
conditions for the operation. 
1.3 Target group 
WARNING! To avoid hazards for the operator and damages 
of  the  device,  following  described  instructions  have  to  be 
worked out by qualied technical personnel. 
1.4 Limitation of liability 
No liability is assumed and warranty claims are excluded in case 
of non-observance of the operating manual, improper application, 
modication of or damage to the device. 
1.5 Intended use 
- The  battery  powered  digital  gauge  has  been  designed  for 
extremely  high  demands  in  the  sector  of  calibration  and  test 
technology.   can be easily and quickly installed in situ. It
- It  is  in  the  responsibility  of  the  user  to  verify  whether  the 
chosen device is  suitable for the intended application. In case 
of  any  doubts,  contact our  sales  department  to eliminate  any 
indistinctness.  PCE Instruments does  not assume any  liability 
for an incorrect selection and its consequences! 
WARNING! - Danger through improper usage  ! 
1.6 Package contents 
Please  verify that  all listed parts  are undamaged  included in the 
delivery and check for consistency specied in your order. 
The  batteries  are  already  used.  The  circuit  is  interrupted  by  an 
insulation  foil.  Take  this  before  rst introduction,  see  in addition 
battery change!! 
2 Mechanical Installation. 
2.1 Mounting and safety instructions 
WARNING! Mount the device (pressure transmitter module)  
always in the state without pressure and apart from the dis-
play! 
WARNING! This  device  may  only  be  installed  by  qualied  
technical  personnel  who  has  read  and  understood  the 
operating manual! 
WARNUNG! Do  not  use  the  display  to  tighten  or  solve  to  
the mechanical connection of the pressure transmitter mod-
ule! 
!Handle  this  electronic  precision measuring  device  carefully 
in packed as well as in unpacked condition! 
!The  device  must  not  be  subject  to  any  changes  or 
modications. 
!The device may not be thrown!
!To  avoid damaging  the  diaphragm,  remove packaging  and 
protective  cap only directly before starting up the  device. A 
delivered protective cap must be stored! 
!Place  the  protective  cap  on  the  pressure  port  again 
immediately after disassembling. 
!Handle the unprotected diaphragm very  carefully - it is very 
sensitive and may be easily damaged. 
!Do  not use  any force  when installing  the  device  to prevent 
damage of the device and the plant! 
Take  note  that  no  inadmissibly  high  mechanical  stresses 
occur  at  the  pressure  port  as  a  result  of  the  installation, 
since this may cause a shifting of the characteristic curve or
to  the  demage.  This  is  especially  important  for  very  small 
pressure ranges as well as for devices with a pressure port 
made of plastic. 
In hydraulic systems, position the device in such a way that 
the pressure port points upward (venting). 
Provide a cooling line when using the device in steam lines. 
2.2 General installation steps 
- Carefully  remove  the  pressure  measuring  device  from  the
package and dispose of the package properly. 
- Then  go  ahead  as  detailed  in  the  specic  instructions 
below. 
2.3 Installation steps for DIN   3852
DO NOT  USE ANY ADDITIONAL SEALING MATERIALS, 
LIKE YARN, HEMP OR TEFLON TAPE! 
- Check  to ensure  the proper  groove  fitting  of the  o-ring  and 
additionally to ensure no damage to the o-ring. 
- Ensure that the sealing surface of the taking part is perfectly 
smooth and clean. (R
Z 
3.2) 
- Screw the device into the corresponding thread by hand.
- If you have a device with a knurled ring, the transmitter has 
to be screwed in by hand only. 
- Devices  with  a  spanner  flat  have  to  be fully tightened  with 
an open-end Devices (G1/4": approx. 5  Nm; G1/2": approx. 
10 Nm  ).
-The  indicated  tightening  torques  must  not  be 
exceeded! 
2.4 Installation steps for EN   837
- Use  a  suitable  seal,  corresponding  to the  medium  and  the
pressure input (e. g. a cooper gasket). 
- Ensure that the sealing surface of the taking part is perfectly 
smooth and clean. (R
Z
 6.3) 
- Screw the device into the corresponding thread by hand.
- Tighten  it  with  a  wrench  (for  G1/4":  approx.  20  Nm;  for
G1/2": approx. 50 Nm). 
-The  indicated  tightening  torques  must  not  be 
exceeded! 
2.5 Installation steps for NPT 
- Use a suitable seal (e. g. a PTFE-strip). 
- Screw the device into the corresponding thread by hand.
- Tighten  it with  a  wrench (for 1/4"  NPT:  approx 30  Nm;  for. 
1/2" NPT: approx. 70 Nm). 
-The  indicated  tightening  torques  must  not  be 
exceeded! 
2  Installation steps for internal threads M20x1.5 and 9/16" .6
UNF (for DM01-500 HD) 
- Screw the high pressure connection into the internal thread 
of the pressure port and tighten it properly with approx. 160 
Nm. 
-DANGER! The  high  pressure tube  seals  metal- -metal to
in  the  chamfer  of  the  pressure  port.  No  further  seal  is 
allowed  with  this  high  pressure  connection.  A  wrong 
installation can cause enormous danger! 
3 Connection display with pressure transmitter module. 
Connect display with   module as follows: pressure transmitter
- bring  together  carefully  the  display  with  pressure transmit-
ter module. 
- press  the  display  sturdy    module  to  this pressure  transmitter
engages.
4  . Supply / changing the batteries
As  soon  as  in  the  display  the  announcement  of  "battery"  is 
shown, carry out battery change as follows: 
-unscrew three xing screws with a suitable screwdriver.
-take the battery case cap and exchange the batteries 3 x
1.5 V AA (remove the insulation foil before first intro-
duction). 
-lock the device after that properly
!An incorrect usage may cause a leak out of batteries and
so a damage the  ! device
!Never combine batteries of dierent types or old with new
ones! 
!Make sure that the batteries are connected correctly with
the corresponding contacts in the battery tray.
!Never try to charge batteri es, demount them, or short -
circuit them. 
!use only batteries with UL certication
!Keep the batteries away from heat and unshielded  ame.
5. Data logger 
The battery powered digital gauge disposes of an integrated data 
logger.  The measuring  values stored  away in  the  device can  be 
selected  above  the  communication  interface  by  means  of 
software. 
5.1 PC - connection 
Connect   with a computer as follows: device
-unscrew the protective screwing of the communication
interface with a suitable slit screwdriver.
-connect the handle plug of the connecting cable (included
in delivery) with the interface socket of the  . Codevice n-
nect the side with the USB plug with a free USB connec-
tion on the computer. 
-install the COM dri ver and data logger software .
-after the use, disconnect the connection and lock the
protection screwing again properly.
6 Initial start-  .  up
 remove the insulation foil before rst introduction . 
WARNING! Before  start-up,  the  user  has  to  check  for  
proper installation and for any visible defects. 
WARNING! The  device  can  be  started  and  operated  by  
authorized  personnel  only,  who  have  read  and  understood 
the operating manual!! 
WARNING! The device has to be used within the technical  
specications, only (compare the data in the data sheet)! 
7 Placing out of service . 
WARNING! When dismantling the device, it must always be  
done in the depressurized and currentless condition! Check 
also if the medium has to be drained o before dismantling! 
WARNING! Depending  on  the  medium,  it  may  cause  
danger  for  the  user.  Comply  therefore  with  adequate 
precautions for purication. 
8 Operation . 
8.1 Operating and display elements 
The  display  of  the  measuring  value  as  well  as  configuring  the 
single  parameters  occurs  menu-steered  about  a  LC  display 
capable of graphic arts. The single functions are regulated on the 
basis of three-front-sided arranged push buttons. 
The  menu  system  is  closed,  thereby  one  can  "browse"  forward 
as well as backward  by the single  setting menus to  reach to the 
desired setting point. 
8.2 Structure of the menu system 
Fig 3 Display and operating foil . 
b ograph ar
display 
right button 
menu button 
left button 
Fig. 2   Battery case cap and communication interface
battery case 
battery case cap 
xing screw 
connecting cable 
comm. - 
interface 
insulation foil 
protection screwing 
battery 
timer / battery 
pressure value 
time 
temperature 
Fig 1   .  Lock against protection
lock against 
protection 
pressure transmit-
ter module 
display 
PCE Americas Inc.
711 Commerce Way 
Suite 8 
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Unit 11 
Southpoint Business Park 
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
 info@pce-instruments.co.uk
Produkspesifikasjoner
| Merke: | PCE Instruments | 
| Kategori: | Måleutstyr | 
| Modell: | PCE-DMM 60 | 
Trenger du hjelp?
Hvis du trenger hjelp med PCE Instruments PCE-DMM 60 still et spørsmål nedenfor, og andre brukere vil svare deg
Måleutstyr PCE Instruments Manualer
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            Måleutstyr Manualer
- Senseca
- Softing
- Toolland
- SHX
- Intact
- Be Cool
- Metrix
- Techno Line
- Kübler
- PCE
- Rotronic
- Reely
- Wachendorff
- Kyoritsu
- HT Instruments
Nyeste Måleutstyr Manualer
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025