InstallationGuideRIGOL
1
DP700 Rack Mount Kit
RM-3-DP700
This rack mount kit (RM-3-DP700) is designed to mount three RIGOL DP700 series
programmable linear DC power supplies into a 19-inch cabinet that conforms to the
Electronic Industries Association (EIA) standard.
Kit Part Checklist (RM-3-DP700)
No. Name Qty. Description
1 Right Fastener 1 --
2 Connecting Plate A 2 --
3 Connecting Plate B 2 --
4 Left Fastener 1 --
5 M4 Screw 28 M4x8 Phillips Pan Head Screw
6 M4 Screw 8 M4x8 Phillips Countersunk Flat Head Screw
7 Rail 2 --
8 Bottom Plate 1 --
9 Side Beam Fastener 4 --
10 Retaining Bracket 4 --
11
M6 Screw 12 M6x16 Phillips Pan Head Screw
12 M6 Nut 12 M6 Square Lock Cage Nut
RIGOL
2
3
6
1
4
7
8
9
10
5
5 6 11 12
InstallationGuideRIGOL
2
Installation Tool
The PH2 Philips screwdriver is recommended.
Space Requirements
To mount the instrument into the cabinet correctly, please ensure that the following
requirements are met:
The cabinet must be a standard 19-inch one.
The available height of the cabinet should be at least 4U.
The depth of the cabinet should be at least 500 mm.
The dimensions of the rack are as shown below.
Unit: mm
Installation Procedures
CAUTION
Only authorized operators are allowed to perform the installation. Improper
installation might cause damage to the instrument or an installation failure.
1. Remove the four rubber protective covers located at the four corners of the front
panel and the four ones at the corners of the rear panel of the instrument
respectively.
2. Attach two rails (with the U-channel
facing outward) to both sides of the
bottom plate, and then fasten them
with eight M4 pan head screws.
3. Attach two side beam fasteners to
the front ends of each rail, as shown
in the figure below, and then secure
them with four M4 pan head screws.
InstallationGuideRIGOL
3
4. Secure the side beam fasteners to the
cabinet by using four M6 screws and
four M6 nuts.
5. Attach another two side beam
fasteners to the back ends of each
rail respectively, as shown in the
figure below, and then secure them
with four M4 pan head screws. Use
four M6 screws and four M6 nuts to
secure the side beam fasteners to the
cabinet.
6. Attach each pair of connecting plates to
two adjacent instruments respectively
(first mount Connecting Plate A at the
left side of Instrument A, and then
mount Connecting Plate A and B in an
alternating order), and secure them
with eight M4 countersunk flat head
screws.
7. Connect the three instruments by
joining each pair of connecting
plates.
InstallationGuideRIGOL
4
8. Place four retaining brackets onto the
connecting positions of the rear panels
of the three instruments, and then
secure the retaining brackets with eight
M4 pan head screws.
9. Attach the left fastener to the left side
of Instrument C, and secure it with
two M4 pan head screws.
10. Attach the right fastener to the right
side of Instrument A, then secure it
with two M4 pan head screws.
11. Place the assembled instruments and
rack onto the bottom plate. Then,
secure the left and right fasteners to
the cabinet by using four M6 screws
and four M6 nuts.
Connecting Plate A
-End-
Connecting Plate B
Instrument B
Instrument B
Instrument A
Instrument C
Instrument A
Instrument B
Instrument C
Instrument C
Instrument A
Instrument B
Instrument A
Instrument C