Owner’s Manual
WARRANTY
REGISTRATION:
register online today for a
chance to win a FREE Tripp Lite
product—www.tripplite.com/warranty
SmartOnline
™
Hot-Swappable Modular
Intelligent True On-Line UPS Systems
Models: SU5000RT4U, SU6000RT4U and SU8000RT4U
Not suitable for mobile applications.
Important Safety Warnings
2
Features
3
Mounting
5
Connection
6
Optional Connection
7
Manual Bypass Operation
9
Operation
11
Internal Battery Replacement
16
Storage/Service
16
Warranty/Warranty Registration
17
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
Copyright © 2011 Tripp Lite. All rights reserved. SmartOnline™ is a trademark of Tripp Lite.
Español
18
Français
35
201102170 932611.indd 1 3/30/2011 10:22:08 AM

2
Important Safety Warnings
SAVE THESE INSTRUCTIONS. This manual contains important instructions and warnings that should be
followed during the installation and maintenance of this UPS System. Failure to heed these warnings may
affect your warranty.
UPS Location Warnings
• TheUPSisextremelyheavy.Usecautionwhenliftingandinstalling.
• InstallyourUPSindoors,awayfromexcessmoistureorheat,directsunlight,dustandconductivecontaminants.
• InstallyourUPSinastructurallysoundarea.
• OnlyoperateyourUPSatindoortemperaturesbetween32°Fand104°F(between0°Cand40°C).Forbestresults,keepindoor
temperaturesbetween62°Fand84°F(between17°Cand29°C).
• LeaveadequatespacearoundallsidesoftheUPSforproperventilation.Donotobstructitsventilationfansoropenings.
• DonotinstalltheUPSnearmagneticstoragemedia,asthismayresultindatacorruption.
• Do not mount unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the
unit's internal cooling, eventually causing product damage not covered under warranty.
UPS Connection Warnings
• Thepowersupplyforthisunitmustbesplit-phaseratedinaccordancewiththeequipmentnameplate.Italsomustbesuitablygrounded.
• ConnectyourUPSsystemonlytoafour-wireinputpowerconnection(L1,L2,N,G).ThisUPSrequiresaninputneutralconnection.
• ConnectyourUPStoaproperlygroundedACpoweroutlet.DonotmodifytheUPS'spluginawaythatwouldeliminatetheUPS's
connectiontoground.(Note: Model SU8000RT4U has a hardwire input instead of an input cord/plug.)
• DonotuseadaptersthateliminatetheUPS'sconnectiontoground.
• DonotplugyourUPSintoitself;thiswilldamagetheUPSandmayaffectyourwarranty.
• IfyouareconnectingyourUPStoamotor-poweredACgenerator,thegeneratormustprovidefiltered,frequency-regulated
computer-gradeoutput.ConnectingyourUPStoageneratormayaffectitsUltimateLifetimeInsurance.
Equipment Connection Warnings
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcanreasonablybeexpectedtocausethefailureofthe
lifesupportequipmentortosignificantlyaffectitssafetyoreffectivenessisnotrecommended.Donotusethisequipmentinthepresence
ofaflammableanestheticmixturewithair,oxygenornitrousoxide
• TheUPScontainsaninternalDCenergysource(battery).TheoutputterminalsmaybeliveevenwhentheUPSisnotconnectedtoan
ACpowersource.
• DonotconnectsurgesuppressorsorextensioncordstotheoutputofyourUPS.ThismightdamagetheUPSandmayaffectthesurge
suppressorandUPSwarranties.
Maintenance Warnings
• YourUPSdoesnotrequireroutinemaintenance.DonotopentheUPSforanyreason.Therearenouser-serviceablepartsinside.
Battery Warnings
• TheinternalbatteriesinyourUPSarerecyclable.Refertolocalcodesfordisposalrequirements,orifintheUSAcall1-800-SAV-LEAD
(1-800-728-5323)forcompleterecyclinginformation.CAUTION:Donotdisposeofthebatteriesinafire,asthiscouldcausethebattery
toexplode.
• Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.Observeproperprecautions.Donotdisposeofthe
batteriesinafire.DonotopentheUPSorbatteries.Donotshortorbridgethebatteryterminalswithanyobject.Unplugandturnoffthe
UPSbeforeperformingbatteryreplacement.Usetoolswithinsulatedhandles.Therearenouser-serviceablepartsinsidetheUPS.Battery
replacementshouldbeperformedonlybyauthorizedservicepersonnelusingthesamenumberandtypeofbatteries(SealedLead-Acid).
Thebatteriesarerecyclable.RefertoyourlocalcodesfordisposalrequirementsorintheUSAonlycall1-800-SAV-LEADor
1-800-8-BATTERY(1-800-822-8837)orvisitwww.rbrc.comforrecyclinginformation.TrippLiteoffersacompletelineofUPSSystem
ReplacementBatteryCartridges(R.B.C.).VisitTrippLiteontheWebatwww.tripplite.com/support/battery/index.cfmtolocatethe
specificreplacementbatteryforyourUPS.
• Donotopenormutilatethebatteries.Releasedelectrolyteisharmfultotheskinandeyes,andmaybetoxic.
• Fusesshouldbereplacedonlybyfactory-authorizedpersonnel.Blownfusesshouldbereplacedonlywithfusesofthesamenumberandtype.
• Serviceandrepairshouldbedoneonlybytrainedpersonnel.DuringanyserviceworktotheUPS,itshouldbeturnedoff.Notethat
potentiallylethalvoltagesexistwithinthisunitaslongasthebatterysupplyisconnected.
• Donotconnectordisconnectexternalbatterypack(s)whiletheUPSisoperatingfromthebattery.
• Duringhot-swapbatteryreplacement,theUPSwillnotprovidebackuppowerintheeventofablackoutorotherpowerinterruptions.
• DonotoperateUPSwithoutbatteries.
• Whenaddingexternalbatterypackstomodelswithexternalbatterypackconnectors,connectonlyTrippLite-recommendedbatterypacks
ofthecorrectvoltageandtype.
201102170 932611.indd 2 3/30/2011 10:22:09 AM

3
Features
Front Panel Controls
I/P BYPASS
BATTERYAC/DC DC/AC O/P
OFFON
MUTE SELECT
SETUP
LCD Display:ThisbacklitdotmatrixdisplayindicatesawiderangeofUPSoperatingconditionsanddiagnosticdata.Italsodisplays
UPSsettingsandoptionswhentheUPSisinsetupmode.
“ON/MUTE” Button:PressthisbuttonandholdituntilyouhearabeeptoturntheUPSsystem'sinverterON.IftheUPS'sbattery
alarmissounding,pressthisbuttontosilenceit.
Scroll Down Button:ThisbuttonallowsyoutobrowsethroughdifferentoptionsandpowerreadingsontheLCDdisplay.Momentarily
pressingitcausestheLCDscreentodisplayadifferentpowerreading(see“Operation”section).PressingitandtheSCROLLUPButton
togetherputstheUPSinsetupmode,wherethisbuttonisusedtoscrollthroughsetupoptionsandtoexitsetupmode.Pressingthe
SCROLLUPandSCROLLDOWNbuttonssimultaneouslyforlongerthanonesecondwhiletheUPSisin"ONBATTERYMODE"
allowsyoutochangetheoutputvoltageoftheUPS(referto"OutputVoltageSelection"inthe"Operation"sectionfordetails).
Scroll Up/“SELECT” Button:ThisbuttonallowsyoutobrowsethroughdifferentoptionsandpowerreadingsontheLCDdisplay.
MomentarilypressingitcausestheLCDscreentodisplayadifferentpowerreading(see"Operation"section).PressingtheSCROLLUP
ButtonandSCROLLDOWNButtonatthesametimeprovidesaccesstotheconfigurationoptionsoftheUPSwhichincludeenablingor
disablingtheUPS"EconomyMode"featureorchangingtheoutputvoltageoftheUPS.(Referto"ConfigurationMenu"inthe
"Operation"sectionfordetails.)
“OFF” Button:Pressthisbuttonandholdituntilyouhearabeep.TheUPSwilldisplaythefollowingmessage:"SwitchtoBypass
N(ON)/Y(OFF)"ifitissafetodoso.PressingOFFagainwillputtheUPSinBypass,stillprovidingpowertoanyconnectedequipment,
butwillnotsupportalossofutilitypower.
“O/P” (Output) LED:ThisgreenlightwillilluminatetoindicateyourUPSissupplyingACpowertoconnectedequipment.
“DC/AC” (Inverter) LED:ThisgreenlightwillilluminatetoindicatetheUPS'sDC/ACinverterisactivated.
“BYPASS” LED:TheBYPASSLEDwillilluminateasolidamberwhentheUPSisrunninginEconomyModeorflashamberifthe
UPSisinaBYPASSstate.ThisamberlightwillflashwhentheUPSisprovidingfilteredmainspowerwithoutengagingitsconverteror
inverter.IfthisLEDisflashing,connectedequipmentwillnotreceivebatterypowerintheeventofablackout.
“AC/DC” (Converter) LED:ThisgreenlightwillilluminatetoindicatetheUPS'sAC/DCconverterischargingtheconnectedbattery
pack(s).
“BATTERY” LED:ThisredlightwillilluminatewhentheUPSisdischargingthebatterytoprovideconnectedequipmentwithAC
power.AnalarmwillsoundwhichcanbesilencedbypressingtheON/MUTEButton.ThisLEDwillremainlitafterthealarmissilenced.
“I/P” (Input) LED:ThisgreenlightwillilluminatetoindicateanACinputsupplyispresent.
Access Slots:Torotatethecontrols,insertaflatheadscrewdriverintotheseslotsandgentlyleverthepanelout.Takingcarenottoexcessively
twistoryankthecablesconnectingthecontrolstotherestoftheUPS,turnthecontrolstothedesiredorientationandreinsertthem.
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
12
201102170 932611.indd 3 3/30/2011 10:22:09 AM
Produkspesifikasjoner
Merke: | Tripp Lite |
Kategori: | uforstyrret strømtilførsel (UPS) |
Modell: | SU6000RT4U |
Vekt: | 67860 g |
Bredde: | 444.5 mm |
Dybde: | 781 mm |
Høyde: | 177.8 mm |
LED-indikatorer: | Ja |
Opprinnelsesland: | China |
Pakkevekt: | 100700 g |
Antall USB 2.0-porter: | 1 |
Sertifisering: | UL1778, CSA, NOM, FCC Part 15 Category A, ROHS |
Utgangseffekt: | 4200 W |
Utgangsspenning (maks.): | 240 V |
Antall faser: | 1 |
Inngangsspenning (maks.): | 240 V |
Kabellengde: | 3 m |
Produktfarge: | Sort |
Pakkedybde: | 939.8 mm |
Pakkehøyde: | 336.6 mm |
Pakkebredde: | 596.9 mm |
Driftstemperatur (T-T): | 0 - 40 °C |
Oppbevaringstemperaturomåde (Celsius): | -15 - 50 °C |
Harmonisert system (HS)-kode: | 8504.40.8500 |
Formfaktor: | Rackmontering |
Inngangsfrekvens: | - Hz |
Driftshøyde: | 0 - 3000 m |
Kommunikasjonsserieporter: | 1 |
Relativ luftfuktighet under drift (H-H): | 0 - 95 |
Antall AC outlets: | 12 AC-utganger |
Produkter per masterkasse (ytterkasse): | 1 stykker |
Kompatibel med Mac: | Ja |
Innput-forbindelsestype: | L14-30P |
Hørbare alarmer: | Ja |
Output strømkapasitet (VA): | 6 kVA |
Inngangsspenning (min.): | 208 V |
Utgangsspenning (min.): | 120 V |
Nødstrøm av (EPO): | Ja |
Normal backuptid ved halv belastning: | 20 min |
Normal backuptid ved full belastning: | 8 min |
Hot-swap-batterier: | Ja |
Output-forbindelser: | 8 x 5-15/20R\r\n2 x L6-20R\r\n2 x L6-30R |
Trenger du hjelp?
Hvis du trenger hjelp med Tripp Lite SU6000RT4U still et spørsmål nedenfor, og andre brukere vil svare deg
uforstyrret strømtilførsel (UPS) Tripp Lite Manualer
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
uforstyrret strømtilførsel (UPS) Manualer
Nyeste uforstyrret strømtilførsel (UPS) Manualer
5 August 2025
5 August 2025
5 August 2025
5 August 2025
5 August 2025
5 August 2025
5 August 2025
5 August 2025
5 August 2025
5 August 2025