LED Indoor Luminaires               
Lambert Flush Mount  
120-277VAC / 60Hz                
Page 1 of 1 8061270                           R0 
Part # LBTF1624LAJUDSNGY 
  LBTF2032LAJUDSNGY    
Safety Precautions 
  Read all safety precautions and installation instructions carefully before installing or servicing this xture. Failure to comply with these instructions could result in potentially fatal 
electric shock and/or property d  amage.
  It is recommended that a qualied electrician perform all wiring. This xture must be wired in accordance with all national and local electrical codes. 
  Do not handle any energized xture or attempt to energize any xture with wet hands or while standing on a wet or damp surface or in water. 
  This xture is designed for use in a 120-277VAC, 60Hz fused circuit. The xture is compatible with Triac (forward-phase or leading edge) / ELV (reverse phase or trailing edge) and 
0-10 V dimmers. Make sure that the power source conforms to the requirements of the xture. (See labels on the xture housing).  
  To reduce the risk of electrical shock, and to assure proper operation, this xture must be adequately grounded. To accomplish proper grounding, there must be a separate ground 
wire (green) contact between this xture and the ground connection of your main power supply panel.  
  This xture is intended to be used for general indoor lighting in dry or damp locations. 
  Disclaimer 
Changes or modications  : This equipment has been not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES- -005 (B) / NMB 005 (B). These limits are designed to 
provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed 
and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged 
to try to correct the interference by one or more of the following measures: 
• Reorient or relocate the receiver antenna. 
• Increase the separation between the equipment and receiver. 
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 
• Consult with the dealer or an experienced radio/TV technician for help. 
Any modications to this xture may void the warranty and interfere with the safe operation of the luminai  re. 
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may 
cause undesired operation of the device.
Assembly Instructions   
1. Preparing for installation. 
A.  Disconnect electrical power before installing or servicing any part of this xture.   
B.  Remove xture from carton; remove components from hardware kit.   
2. Wiring. All wiring must take place inside junction box.       
Caution: Make sure power is o at fuse or circuit breaker box. Check power wires for damage 
or scrapes.  If the power supply wires are within three inches of the driver, use a wire suitable 
for at least 90C (194F).   Most dwellings built before 1985 have supply wire rated to 60C. Note:
Consult a qualied electrician before installing. 
A.  This unit will not operate properly unless connected to a “grounded” electrical circuit. 
Electrical shock, overheating, low or no light output, and shortened LED life can result if 
proper grounding is not done. Securely attach power source ground wire and xture 
ground wire to green ground screw on circular mounting bracket. 
B.  Make all wire connections to appropriate wire. Secure with wire nuts (provided). 
C.  . Fixture will operate normally w/o connection to any dimmers. For none-dimming xture
Connect white xture lead to white (N) wire from supply power source. Connect black 
xture lead to black (L) wire from supply power source. Gray and purple wires are not to 
be used and must be individually capped to prevent shorting. 
D.  Connect white xture lead to (N) wire from dimming source per For TRIAC dimming. 
dimmer wiring instructions. Connect black xture lead to black (L) wire from dimmer 
supply power source. Gray and purple wires are not to be used and must be individually 
capped to prevent shorting. 
E.  . Connect gray wire from the xture to the dimmer source For (0-10V) dimming xture
gray wire. Connect purple wire from the xture to the dimmer source purple wire. Connect 
white xture lead to white (N) wire from supply power source. Connect black xture lead 
to black (L) wire from dimmer supply power source. 
F.  . Pull on each wire lead to make sure connections are secure. Make Do not mix wires
certain no bare wires are exposed outside of wire connectors. Tuck all connections neatly into junction box. 
3. Back pan mounting. 
A.  Install ceiling pan  ) to junction box (NOT INCLUDED) with two screws (2). (1
4. Color Changing Temperature Adjustment, CCT (if desired). 
A.  Adjust the two switches on each board accordingly to the desired color temperature as seen below. All boards must be 
set the same way.   Fixture is preset to 3500K from factory.  Note:
5. Mounting diuser. 
A.  Raise the shade (3), up to the ceiling aligning the tabs shown in Fig. 2 with slots in ceiling pan.   
B.  Rotate the shade with all 4 pins aligned in the slots until they bottom out and are resting in the detent. 
6. Power to the xture can now be restored. 
Limited Factory Warranty 
AFX Inc. hereby warranty that this xture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 5 years 
from date of shipment from factory. This warranty covers all component parts and extends only to replacement of defective xture or components; it does not cover failure due 
to improper installation, misuse, mishandling or damage incurred in transit. 
Fig. 2 
Lift & Twist Mount 
Produkspesifikasjoner
| Merke: | AFX | 
| Kategori: | Lettelse | 
| Modell: | Lambert LBTF1624LAJUDSNGY | 
Trenger du hjelp?
Hvis du trenger hjelp med AFX Lambert LBTF1624LAJUDSNGY still et spørsmål nedenfor, og andre brukere vil svare deg
Lettelse AFX Manualer
                        
                         3 April 2025
                        
                    
                                                            
                        
                         15 Oktober 2024
                        
                    
                                                            
                        
                         15 Oktober 2024
                        
                    
                                                            
                        
                         15 Oktober 2024
                        
                    
                                                            
                        
                         15 Oktober 2024
                        
                    
                                                            
                        
                         15 Oktober 2024
                        
                    
                                                            
                        
                         15 Oktober 2024
                        
                    
                                                            
                        
                         15 Oktober 2024
                        
                    
                                                            
                        
                         15 Oktober 2024
                        
                    
                                                            
                        
                         15 Oktober 2024
                        
                    
                                                            Lettelse Manualer
- SilverStone
- Angler
- Kuzco
- Olight
- GRE
- Peerless-AV
- Kern
- Sagitter
- GoGEN
- Amaran
- Karma
- ARRI
- Varaluz
- NEO Tools
- Behringer
Nyeste Lettelse Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         6 April 2025
                        
                    
                                                            
                        
                         6 April 2025
                        
                    
                                                            
                        
                         6 April 2025
                        
                    
                                                            
                        
                         6 April 2025