Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking
flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you al-
ready know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
LOSONE SELECT
®
VENTILATORS
In-Line • 120V
READ AND SAVE THESE INSTRUCTIONS
TABLE OF CONTENTS
This manual is divided into sections as follows:
• “TYPICAL INSTALLATION”
This section shows a common installation in new and existing,
frame construction.
- Mounting (new construction)
- Mounting (existing construction)
- Wiring
- Ducting (straight through blower discharge)
• “MOUNTING OPTIONS”
• “WIRING OPTIONS”
- Wiring Plate Position
• “DUCTING OPTIONS”
- Blower Discharge Positions
- Ducting (right angle blower discharge)
• “USE AND CARE”
• “SERVICE PARTS”
• “WARRANTY”
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 3.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such as
an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further informa-
tion and requirements.

MODELS
L100L • L150L • L200L • L250L • L300L
Page 2
TYPICAL INSTALLATION
MOUNTING
(New Frame Construction)
CEILING JOIST
(16” centers shown)
ROUND DUCT*
Factory-shipped unit installed in new construction.
MOUNTING
SCREW
Blower factory-shipped
in straight through
discharge position.
Mounting brackets
factory-shipped in
position for ½”
ceiling material.
ADDITIONAL
1½” FRAMING
MOUNTING
(Existing Frame Construction)
Factory-shipped unit installed in existing construction.
TYPICAL INSTALLATION
WIRING
WIRING
PLATE
WHITE
TO
WHITE
BLACK
TO
BLACK
TOP / BACK
OF HOUSING
120 VAC LINE IN
GROUND TO
WIRING PLATE
ROUND DUCT*
FINISHED
CEILING
MATERIAL
CEILING JOIST
(16” centers
shown)
2 X 4 FRAMING
(wide side down)
MOUNTING
BRACKETS
(Attached to
opposite sides
of housing &
upside-down)
DUCTING
(Horizontal blower discharge)
Two ways to connect ductwork to a factory-shipped unit.
Ventilator can be wired from outside of housing.
Use UL approved connectors to wire per local codes.
ROOF CAP
ROUND
ELBOW*
ROUND DUCT*
WALL
CAP
IMPORTANT:
Remove shipping tape from damper
Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork. Use
duct tape to make ductwork connections secure and air-tight.
Remove shipping ring from blower inlet
Remove the shipping ring from the blower inlet before operating
the ventilator.
* L100L & L150L use 6” round duct.
L200L, L250L, & L300L use 8” round duct.
* L100L & L150L use 6” round duct.
L200L, L250L, & L300L use 8” round duct.

MODELS
L100L • L150L • L200L • L250L • L300L
Page 3
12¼"
9
1
/
2"
to
10
1
/
2"
12¼"
1½"
to
2½"
MOUNTING OPTIONS
WIRING OPTIONS
DUCTING OPTIONS
12¼"
1
1
/
8
"
MAX.
Mounting brackets in
factory-shipped position.
(Outlet parallel to joists.)
(
New construction)
12¼"
10
3
/
4
"
to
11
3
/
4
"
12¼"
¼-20 hex nuts secure mounting brackets to housing. Loosen and
re-tighten or remove and replace nuts as necessary for desired
mounting bracket position.
Mounting brackets flipped
over and mounted to outlet
sides of housing.
(Outlet parallel to joists.)
(
Existing construction)
Mounting brackets mounted
to outlet sides of housing.
(Outlet perpendicular to joists.)
(
New construction)
Mounting brackets flipped
over and mounted to top of
sides of housing.
(Outlet parallel to joists.)
(
New or existing construction)
12¼"
1
1
/
2
"
to
2
1
/
2
"
Mounting brackets flipped
over to give approx. 1”
more clearance.
(Outlet parallel to joists.)
(
New construction)
Mounting brackets mounted
to top of sides of housing.
(Outlet parallel to joists.)
(
New or existing construction)
BLOWER DISCHARGE POSITIONS
WIRING PLATE
POSITION
Wiring plate mounts to side or top of housing.
HORIZONTAL POWER
CABLE CONNECTION
VERTICAL
POWER
CABLE
CONNECTION
Blower and duct connector
in
straight through dis-
charge position.
(Factory shipped)
DUCT
CONNECTOR
DUCT
CONNECTOR
Blower and duct connector
in
right angle discharge
position.
BLOWER
BLOWER
Change
blower &
duct
connector
positions for
right angle
discharge.
DUCTING
(Right angle blower discharge)
Typical ductwork connection to a ventilator converted to
right angle discharge.
ROOF CAP
ROUND
DUCT*
WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.
To clean blower assembly: Remove access panel, unplug blower
from housing, remove blower mounting nuts, and carefully remove
blower from housing. Use appropriate vacuum attachment or a soft
cloth and mild soap or detergent to clean blower discharge area
and wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make
sure blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
USE AND CARE
Ventilator is designed for continuous operation. If desired, it may
be controlled using an on/off switch or an electronic, variable speed
control. Follow wiring instructions packed with control, and adhere
to all local and state codes, and the National Electrical Code.
* L100L & L150L use 6” round duct.
L200L, L250L, & L300L use 8” round duct.
Produkspesifikasjoner
Merke: | Broan |
Kategori: | Ventilator |
Modell: | L200L |
Trenger du hjelp?
Hvis du trenger hjelp med Broan L200L still et spørsmål nedenfor, og andre brukere vil svare deg
Ventilator Broan Manualer

3 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025

2 April 2025
Ventilator Manualer
- Ventilator NewAir
- Ventilator Bosch
- Ventilator BEKO
- Ventilator Exquisit
- Ventilator Café
- Ventilator DeWalt
- Ventilator Philips
- Ventilator Thermex
- Ventilator Hotpoint
- Ventilator Cecotec
- Ventilator Enermax
- Ventilator Noveen
- Ventilator Delonghi
- Ventilator Comfee
- Ventilator Imarflex
- Ventilator Kogan
- Ventilator Solis
- Ventilator Nitecore
- Ventilator Create
- Ventilator Kichler
- Ventilator Midea
- Ventilator BlueBuilt
- Ventilator Orbegozo
- Ventilator Kuppersbusch
- Ventilator NEO Tools
- Ventilator Gemini
- Ventilator Koenic
- Ventilator Panasonic
- Ventilator Lian Li
- Ventilator Westinghouse
- Ventilator Sencor
- Ventilator Canarm
- Ventilator Orava
- Ventilator Mistral
- Ventilator Khind
- Ventilator EMOS
- Ventilator Clean Air Optima
- Ventilator Taurus
- Ventilator Dimplex
- Ventilator Ryobi
- Ventilator Breville
- Ventilator Bimar
- Ventilator Sharkoon
- Ventilator Gamdias
- Ventilator Concept
- Ventilator Livoo
- Ventilator Brandson
- Ventilator CSL
- Ventilator Ausclimate
- Ventilator Nevir
- Ventilator Infiniton
- Ventilator Ufesa
- Ventilator Milwaukee
- Ventilator Omega Altise
- Ventilator Scarlett
- Ventilator Daikin
- Ventilator Rowenta
- Ventilator Be Cool
- Ventilator Blaupunkt
- Ventilator Thermaltake
- Ventilator Master
- Ventilator V-Tac
- Ventilator Termozeta
- Ventilator Tristar
- Ventilator Hunter
- Ventilator Ebm-papst
- Ventilator DeepCool
- Ventilator Nedis
- Ventilator Magmatic
- Ventilator Eldom
- Ventilator Elba
- Ventilator Vonroc
- Ventilator Worx
- Ventilator Brentwood
- Ventilator ECG
- Ventilator Renkforce
- Ventilator Modern Fan Co.
- Ventilator Quorum International
- Ventilator Bestron
- Ventilator Soler And Palau
- Ventilator Bionaire
- Ventilator Toshiba
- Ventilator S&P
- Ventilator Eurolite
- Ventilator EVOLVEO
- Ventilator Innoliving
- Ventilator Mystery
- Ventilator Middle Atlantic
- Ventilator Duracraft
- Ventilator Mellerware
- Ventilator Home Electric
- Ventilator Tefal
- Ventilator Perfect Aire
- Ventilator Svan
- Ventilator LifeSmart
- Ventilator Signature
- Ventilator Izzy
- Ventilator Lasko
- Ventilator LC-Power
- Ventilator Be Quiet!
- Ventilator Biltema
- Ventilator Emerio
- Ventilator Prime3
- Ventilator KDK
- Ventilator Vornado
- Ventilator Keystone
- Ventilator Savio
- Ventilator InLine
- Ventilator Ardes
- Ventilator Honeywell
- Ventilator Fantini Cosmi
- Ventilator Baxi
- Ventilator Haus & Luft
- Ventilator Ideal
- Ventilator Casablanca
- Ventilator Yamazen
- Ventilator Unold
- Ventilator Aspes
- Ventilator Soler & Palau
- Ventilator Sôlt
- Ventilator Proline
- Ventilator Tornado
- Ventilator Windmill
- Ventilator Premium
- Ventilator ActiveJet
- Ventilator Aerian
- Ventilator Gutfels
- Ventilator Grunkel
- Ventilator Duux
- Ventilator Proficare
- Ventilator Listo
- Ventilator GoldAir
- Ventilator Heller
- Ventilator Magnavox
- Ventilator SHE
- Ventilator Air&Me
- Ventilator Cli-Mate
- Ventilator Geek Aire
- Ventilator Essentiel B
- Ventilator EWT
- Ventilator Click
- Ventilator Bestherm
- Ventilator ThreeSixty
- Ventilator Valueline
- Ventilator PAX
Nyeste Ventilator Manualer

9 April 2025

9 April 2025

9 April 2025

3 April 2025

2 April 2025

1 April 2025

1 April 2025

1 April 2025

1 April 2025

1 April 2025