Broan QTXE110S Bruksanvisning
                    Broan
                    
                    Ventilator
                    
                    QTXE110S
                
                                
                
                
                                
                Les nedenfor 📖 manual på norsk for Broan QTXE110S (4 sider) i kategorien Ventilator. Denne guiden var nyttig for 34 personer og ble vurdert med 4.8 stjerner i gjennomsnitt av 17.5 brukere
                        Side 1/4
                    
                    
                    
Page 1
MODELS   QTXE110S • QTXE110S2  
WARNING     
TO REDUCE THE RISK OF FIRE, ELEC-
TRIC SHOCK, OR INJURY TO PERSONS, 
OBSERVE THE FOLLOWING:
1.  Use this unit only in the manner intended 
by the manufacturer. If you have questions, 
contact the manufacturer at the address or 
telephone number listed in the warranty.
2.  Before servicing or cleaning unit, switch 
power off at service panel and lock the ser-
vice disconnecting means to prevent power 
from being switched on accidentally. When 
the service disconnecting means cannot be 
locked, securely fasten a prominent warning 
device, such as a tag, to the service panel.
3.  Installation work and electrical wiring must be 
done by a qualified person(s) in accordance 
with all applicable codes and standards, 
including fire-rated construction codes and 
standards.
4.  Sufficient air is needed for proper combus-
tion and exhausting of gases through the 
flue (chimney) of fuel burning equipment to 
prevent backdrafting. Follow the heating equip-
ment manufacturer’s guideline and safety 
standards such as those published by the 
National Fire Protection Association (NFPA), 
and the American Society for Heating, Re-
frigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities.
5.  When cutting or drilling into wall or ceiling, do 
not damage electrical wiring and other hidden 
utilities.
6.  Ducted fans must always be vented to the 
outdoors.
7.  Acceptable for use over a tub or shower when 
connected to a GFCI (Ground Fault Circuit 
Interrupter) - protected branch circuit.
8.  This unit must be grounded.
CAUTION  
1.  For general ventilating use only. Do not use 
to exhaust hazardous or explosive materials 
and vapors.
2.  This product is designed for installation in flat 
ceilings only. DO NOT MOUNT THIS PROD-
UCT IN A WALL.
3.  To avoid motor bearing damage and noisy 
and/or unbalanced impellers, keep drywall 
spray, construction dust, etc. off power unit.
4.  Please read specification label on product for 
further information and requirements.
HUMIDITY SENSING FAN
READ AND SAVE THESE INSTRUCTIONS
CLEANING & 
MAINTENANCE
Installer: Leave this manual 
with the homeowner.
For quiet and efficient operation, long life, 
and attractive appearance - lower or remove 
grille and vacuum interior of unit with the 
dusting brush attachment.
The motor is permanently lubricated and 
never needs oiling. If the motor bearings 
are making excessive or unusual noises, 
replace the motor/blower wheel assembly.
SENSOR CLEANING
The humidity sensor is mounted in the grille. 
The sensor will operate most reliably when 
cleaned occasionally as follows:
1.  Disconnect power at service entrance.
2.  Remove the grille. Use a dry dustcloth, 
clean toothbrush, or lightly vacuum to 
clean sensor and grille. DO NOT USE 
ABRASIVE CLOTH, STEEL WOOL 
PADS, OR SCOURING POWDERS.
3.  DO NOT USE cleaning sprays, solvents, 
or water on or near the sensor!
OPERATION
The humidity control and fan can be op-
erated separately. Use a 1 or 2-function 
wall control. Do not use a dimmer switch 
to operate the humidity control or light. 
See “Connect Wiring” for details.
SENSOR OPERATION
This humidity-sensing
fan responds to:     (a) 
rapid to moderate humidity increases and 
(b) humidity above a 50%-80% relative 
humidity (RH) set-point. (a) and (b) are 
set with “HUMIDITY” adjustment. Fan may 
occasionally turn on when environmental 
conditions change. If the fan continuously 
responds to changing environmental con-
ditions, “HUMIDITY” adjustment may be 
required (see section below).
STATUS INDICATOR
This indicator can only be seen by looking 
directly at it. Normal mode is 5-seconds  on 
and off.  If it blinks rapidly for 5-seconds and 
then off, check sensor connections on grille 
and fan housing. 
MANUAL ON WITH TIMED OFF
For odor or vapor control, the fan can be 
energized by cycling its wall-mounted switch 
if one is installed. Once the fan has been 
turned on in this manner, it will remain on 
for the set “MINUTES” period.
To manually energize the fan:
1.  Go to Step 2 if switch is already on; 
otherwise, turn switch on for more than 
1 second.
2.  Switch off for less than 1 second.
3.  Switch back on and fan will turn on.
HUMIDITY ADJUSTMENT
“HUMIDITY” has been factory set for most 
shower applications. If the fan is in a tub 
area or is used for dampness control, the 
“HUMIDITY” may need to be decreased 
toward 50% RH. If the control is responding 
too often to changing environmental condi-
tions, adjustment toward 80% RH may be 
required.  To adjust the “HUMIDITY”:
1. Turn power off at electrical service 
panel.
2.  Through the grille, locate the “HUMIDITY” 
screwdriver slot.
3. Using a small, flat-blade screwdriver, 
carefully rotate “HUMIDITY” adjustment 
toward 50 or 80.
4. Turn power on and check operation by 
turning on shower or other humidity 
source until fan turns on.
5.  Repeat above steps if necessary.
TIMER  ADJUSTMENT
This humidity-sensing fan has a timer. It is 
user-adjustable from 5 to 60 minutes and is 
factory-set at 20 minutes. The timer controls 
how long the fan remains on (a) after rise 
in humidity and (b) humidity level are both 
below the user-adjustable “HUMIDITY” 
setting or after being energized by cycling 
power switch.
To adjust the timer:
1.  Disconnect power at electrical service 
panel.
2.  Through the grille, locate the “MINUTES” 
screwdriver slot.
3. Using a small, flat-blade screwdriver, 
carefully rotate “MINUTES” adjustment 
to desired setting (5 to 60 minutes).
4.  Check operation by cycling power switch 
as instructed under “MANUAL ON WITH 
TIMED OFF” or by turning on a humidity 
source until fan turns on.
5.  Check timer setting with watch or clock 
after turning humidity source off if it was 
turned on it Step 4.
6. Repeat above steps if necessary.
To register this product visit:
www.broan.com
Produkspesifikasjoner
| Merke: | Broan | 
| Kategori: | Ventilator | 
| Modell: | QTXE110S | 
Trenger du hjelp?
Hvis du trenger hjelp med Broan QTXE110S still et spørsmål nedenfor, og andre brukere vil svare deg
Ventilator Broan Manualer
                        
                         3 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            Ventilator Manualer
- Mistral
- Grunkel
- Termozeta
- Baxi
- Vornado
- Ausclimate
- Bionaire
- Hotpoint
- CSL
- Lasko
- Innoliving
- Home Electric
- Soler & Palau
- Ideal
- Concept
Nyeste Ventilator Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         1 April 2025
                        
                    
                                                            
                        
                         1 April 2025
                        
                    
                                                            
                        
                         1 April 2025
                        
                    
                                                            
                        
                         1 April 2025
                        
                    
                                                            
                        
                         1 April 2025