Side 1/1

CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK:
Use only in dry locations and only indoors.
DO NOT plug into another relocatable power tap.
DO NOT “daisy chain” surge protectors.
DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available.
DO NOT install this device if there is less than 10 meters (30 feet) of wire between
the electrical outlet and electrical service panel.
DO NOT use for medical or life support equipment. This device features an internal
protection that will disconnect the surge protective component at the end of its
useful life, but it will maintain unprotected power to the load.
FOR MORE INFORMATION
Visit CyberPowerSystems.com for more information regarding:
• Product information and certifications
• Product warranty
• Connected equipment guarantee
TECHNICAL SUPPORT
Visit: CyberPowerSystems.com/support
Toll-Free: 1-877-297-6937
© 2025 Cyber Power Systems (USA), Inc. All rights reserved.
CyberPower and the CyberPower logo are trademarks of Cyber Power Systems,
Inc., and/or aliates, which are registered in many countries and regions. All other
trademarks are the property of their respective owners.
FEATURES
1. ON/OFF Reset Control Switch and Circuit Breaker
Controls power to all outlets. The switch is also a 15A
breaker. When an overload occurs, it will automatically
switch o. To resume operation, ensure the overload
condition is removed and reset the surge protector by
switching the unit ON.
2. Protected LED Indicator
Illuminated when the surge protection feature is
working properly.
3. Grounded LED Indicator
Illuminated when the surge protector is
properly grounded.
4. Standard Grounded Outlets (10)
5. USB-A Charging Port (1)
6. USB-C Charging Port (1)
7. Power Cord
TROUBLESHOOTING
If the ON/OFF Reset Control switches to the OFF position, the 15-amp circuit
breaker may have been tripped. Examine your connected equipment and remove
the device overloading the circuit, causing the trip. Then, turn the ON/OFF Reset
Control back to RESET.
If the GROUNDED indicator does not light when you plug in the surge protector,
move the surge protector to a di˜erent grounded three-prong AC outlet. If the
GROUNDED indicator still does not light and the surge protector appears to be
working correctly, your outlets may not be properly grounded and should be
repaired by a professional electrician.
If the PROTECTED indicator does not light, the surge protector’s outlets are no
longer protected from power surges or spikes. The surge protector may have
received a power surge or spike beyond its specified limits that have overloaded
the protection circuitry and rendered it inactive. The surge protector has protected
your connected equipment as designed, but it will not protect against future
surges and spikes. It should be replaced.
10-OUTLET
SURGE PROTECTOR
WITH 2 USB PORTS
P1004UC15
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com
SPECIFICATIONS
Model Number: P1004UC15
Outlets: Standard Grounded Outlets (10)
Power Cord Length: 4 ft
Surge Protection: 2400 Joules
USB-A Charging Port (1): 5V/2.4A
USB-C Charging Port (1): 5V/3A
USB Total Output: 18W
Electrical Rating: 125V/15A/1875W
UL Clamping Voltage: UL1449 4th/800V(L-N, L-G, N-G)
Maximum Peak Current: 60,000 A
3 AC Lines Protected: L-N: 30,000 A; L-G: 15,000 A;
N-G: 15,000 A
Response Time: Less than 1 nanosecond
Circuit Breaker: Resettable 15 Amp
i WARNING: This product can expose you to chemicals including bisphenol A (BPA)
and styrene (ABS), which is known to the State of California to cause reproductive
harm and cancer. For more information, go to www.P65Warnings.ca.gov..
CONFORMANCE APPROVALS
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be determined by
turning the equipment o and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.
K01-E000117-00
Produkspesifikasjoner
Merke: | CyberPower |
Kategori: | vegguttak |
Modell: | P1004UC15 |
Trenger du hjelp?
Hvis du trenger hjelp med CyberPower P1004UC15 still et spørsmål nedenfor, og andre brukere vil svare deg
vegguttak CyberPower Manualer
1 Oktober 2025
30 September 2025
30 September 2025
vegguttak Manualer
- Craftsman
- Berker
- H-Tronic
- Silverline
- Somfy
- Biltema
- Kogan
- Belkin
- Rocketfish
- Osram
- ORNO
- Adam Hall
- Phoenix Contact
- AV:link
- LEDmaxx
Nyeste vegguttak Manualer
30 September 2025
25 September 2025
23 September 2025
23 September 2025
22 September 2025
21 September 2025
20 September 2025
15 September 2025
15 September 2025
15 September 2025