Installer and user reference guide
Heat reclaim ventilation unit
English
Name Plate
Installer and user
reference guide
Heat reclaim ventilation unit
VAM350J7VEB
VAM500J7VEB
VAM650J7VEB
VAM800J7VEB
VAM1000J7VEB
VAM1500J7VEB
VAM2000J7VEB

Table of contents
Installer and user reference guide
2
VAM350~2000J7VEB
Heat reclaim ventilation unit
4P487293-1A – 2018.05
Table of contents
1 General safety precautions 3
1.1 About the documentation .......................................................... 3
1.1.1 Meaning of warnings and symbols.............................. 3
1.2 For the user ............................................................................... 3
1.3 For the installer.......................................................................... 3
1.3.1 General ....................................................................... 3
1.3.2 Installation site ............................................................ 4
1.3.3 Refrigerant .................................................................. 5
1.3.4 Brine............................................................................ 6
1.3.5 Water .......................................................................... 6
1.3.6 Electrical ..................................................................... 6
2 About the documentation 7
2.1 About this document.................................................................. 7
For the installer 8
3 About the box 8
3.1 Overview: About the box ........................................................... 8
3.2 Heat reclaim ventilation unit ...................................................... 8
3.2.1 To unpack the heat reclaim ventilation unit................. 8
3.2.2 To remove the accessories......................................... 9
3.2.3 To handle the heat reclaim ventilation unit ................. 10
4 About the units and options 10
4.1 Overview: About the units and options...................................... 10
4.2 Identification .............................................................................. 10
4.2.1 Identification label: Heat reclaim ventilation unit......... 10
4.3 About the heat reclaim ventilation unit ...................................... 10
4.4 Combining units and options ..................................................... 11
4.4.1 Possible options for the heat reclaim ventilation unit.. 11
5 Preparation 11
5.1 Overview: Preparation............................................................... 11
5.2 Preparing the installation site .................................................... 11
5.2.1 Installation site requirements for the heat reclaim
ventilation unit ............................................................. 11
5.3 Preparing the unit ...................................................................... 12
5.3.1 To install the optional adapter PCB ............................ 12
5.3.2 To install the duct joints .............................................. 13
5.4 Preparing electrical wiring ......................................................... 13
5.4.1 Wiring connection ....................................................... 13
5.4.2 Component electrical specifications............................ 13
5.4.3 Specifications for field supplied fuses and wires......... 13
5.5 Preparing the installation of the ducts ....................................... 14
6 Installation 15
6.1 Service space: Heat reclaim ventilation unit.............................. 15
6.2 Unit orientation .......................................................................... 15
6.3 To install the anchor bolts ......................................................... 16
6.4 Duct connections....................................................................... 16
6.5 Electrical wiring ......................................................................... 17
6.5.1 Precautions when connecting electrical wiring ........... 17
6.5.2 Opening the switch box............................................... 17
6.5.3 Electrical connections for additional field supplied
damper........................................................................ 20
6.5.4 Power supply connection, control wire terminals and
switches on the PCB................................................... 20
6.5.5 Guidelines when connecting the electrical wiring ....... 21
7 System configuration 21
7.1 About control systems ............................................................... 21
7.2 Independent system .................................................................. 22
7.3 Linked operation control system................................................ 23
7.4 Central control system............................................................... 23
8 Configuration 23
8.1 Operating procedure .................................................................. 24
8.1.1 To change settings....................................................... 24
8.2 List of settings ............................................................................ 25
8.3 Settings for all configurations ..................................................... 29
8.3.1 About setting 19(29)-0-04 and 19(29)-0-05 ................. 30
8.3.2 Independent system..................................................... 30
8.3.3 1-group linked-control system...................................... 30
8.3.4 Linked control with more than 2 groups ....................... 30
8.3.5 Direct duct connection ................................................. 31
8.3.6 Central control system ................................................. 31
8.4 About the controller .................................................................... 32
8.4.1 Controller for VRV system air conditioner.................... 33
8.4.2 Controller for heat reclaim ventilation units.................. 34
8.5 Detailed explanation of settings ................................................. 35
8.5.1 To monitor the unit's operation..................................... 35
8.5.2 About fresh-up operation ............................................. 35
8.5.3 About the external damper operation........................... 36
8.5.4 About the CO2 sensor ................................................. 36
8.5.5 About nighttime free cooling operation ........................ 38
8.5.6 About the precool and preheat function....................... 38
8.5.7 About preventing a feeling of draft............................... 39
8.5.8 About 24-hour ventilation ............................................. 39
8.5.9 About the ultra-low setting ........................................... 39
8.5.10 About the electrical heater operation ........................... 39
8.5.11 About external linkage input......................................... 39
8.5.12 About filter contamination check .................................. 39
9 Commissioning 39
9.1 Overview: Commissioning.......................................................... 39
9.2 Precautions when commissioning .............................................. 39
9.3 Checklist before commissioning................................................. 39
9.4 Checklist during commissioning ................................................. 40
9.4.1 About the test run......................................................... 40
10 Hand-over to the user 40
11 Maintenance and service 40
11.1 Overview: Maintenance and service .......................................... 40
11.2 Maintenance safety precautions................................................. 40
11.2.1 To prevent electrical hazards....................................... 40
11.3 Checklist for maintenance of the heat reclaim ventilation unit ... 41
12 Troubleshooting 41
12.1 Overview: Troubleshooting......................................................... 41
12.2 Precautions when troubleshooting ............................................. 41
12.3 Solving problems based on error codes ..................................... 41
12.3.1 Error codes: Overview ................................................. 41
13 Disposal 42
14 Technical data 42
14.1 Wiring diagram: Heat reclaim ventilation unit ............................. 42
For the user 43
15 Controller 43
16 Before operation 43
17 Energy saving and optimum operation 43
18 Maintenance and service 43
18.1 Maintenance of the air filter ........................................................ 43
18.2 Maintenance of the heat exchange element .............................. 44
19 Troubleshooting 44
20 Relocation 45
21 Disposal 45

1 General safety precautions
Installer and user reference guide
3
VAM350~2000J7VEB
Heat reclaim ventilation unit
4P487293-1A – 2018.05
22 Glossary 45
1 General safety precautions
1.1 About the documentation
▪ The original documentation is written in English. All other
languages are translations.
▪ The precautions described in this document cover very important
topics, follow them carefully.
▪ The installation of the system, and all activities described in the
installation manual and the installer reference guide MUST be
performed by an authorised installer.
1.1.1 Meaning of warnings and symbols
DANGER
Indicates a situation that results in death or serious injury.
DANGER: RISK OF ELECTROCUTION
Indicates a situation that could result in electrocution.
DANGER: RISK OF BURNING
Indicates a situation that could result in burning because of
extreme hot or cold temperatures.
DANGER: RISK OF EXPLOSION
Indicates a situation that could result in explosion.
WARNING
Indicates a situation that could result in death or serious
injury.
WARNING: FLAMMABLE MATERIAL
CAUTION
Indicates a situation that could result in minor or moderate
injury.
NOTICE
Indicates a situation that could result in equipment or
property damage.
INFORMATION
Indicates useful tips or additional information.
Symbol Explanation
Before installation, read the installation and
operation manual, and the wiring instruction sheet.
Before performing maintenance and service tasks,
read the service manual.
For more information, see the installer and user
reference guide.
1.2 For the user
▪ If you are NOT sure how to operate the unit, contact your installer.
▪ This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in
a safe way and understand the hazards involved. Children shall
NOT play with the appliance. Cleaning and user maintenance
shall NOT be made by children without supervision.
WARNING
To prevent electric shocks or fire:
▪ Do NOT rinse the unit.
▪ Do NOT operate the unit with wet hands.
▪ Do NOT place any objects containing water on the unit.
NOTICE
▪ Do NOT place any objects or equipment on top of the
unit.
▪ Do NOT sit, climb or stand on the unit.
▪ Units are marked with the following symbol:
This means that electrical and electronic products may NOT be
mixed with unsorted household waste. Do NOT try to dismantle
the system yourself: the dismantling of the system, treatment of
the refrigerant, of oil and of other parts must be done by an
authorized installer and must comply with applicable legislation.
Units must be treated at a specialized treatment facility for reuse,
recycling and recovery. By ensuring this product is disposed of
correctly, you will help to prevent potential negative consequences
for the environment and human health. For more information,
contact your installer or local authority.
▪ Batteries are marked with the following symbol:
This means that the batteries may NOT be mixed with unsorted
household waste. If a chemical symbol is printed beneath the
symbol, this chemical symbol means that the battery contains a
heavy metal above a certain concentration.
Possible chemical symbols are: Pb: lead (>0.004%).
Waste batteries must be treated at a specialized treatment facility
for reuse. By ensuring waste batteries are disposed of correctly,
you will help to prevent potential negative consequences for the
environment and human health.
1.3 For the installer
1.3.1 General
If you are NOT sure how to install or operate the unit, contact your
dealer.
NOTICE
Improper installation or attachment of equipment or
accessories could result in electric shock, short-circuit,
leaks, fire or other damage to the equipment. Only use
accessories, optional equipment and spare parts made or
approved by Daikin.
WARNING
Make sure installation, testing and applied materials
comply with applicable legislation (on top of the
instructions described in the Daikin documentation).
CAUTION
Wear adequate personal protective equipment (protective
gloves, safety glasses,…) when installing, maintaining or
servicing the system.
Produkspesifikasjoner
Merke: | Daikin |
Kategori: | Varmepumpe |
Modell: | VAM350J7VEB |
Trenger du hjelp?
Hvis du trenger hjelp med Daikin VAM350J7VEB still et spørsmål nedenfor, og andre brukere vil svare deg
Varmepumpe Daikin Manualer
26 August 2025
26 August 2025
26 August 2025
26 August 2025
26 August 2025
26 August 2025
26 August 2025
26 August 2025
27 Oktober 2024
27 Oktober 2024
Varmepumpe Manualer
- Varmepumpe LG
- Varmepumpe Bosch
- Varmepumpe Grundig
- Varmepumpe Hisense
- Varmepumpe Electrolux
- Varmepumpe Balay
- Varmepumpe Siemens
- Varmepumpe Arcelik
- Varmepumpe Hotpoint
- Varmepumpe AEG
- Varmepumpe Inventum
- Varmepumpe Samsung
- Varmepumpe Midea
- Varmepumpe Danfoss
- Varmepumpe Gorenje
- Varmepumpe Olimpia Splendid
- Varmepumpe Westinghouse
- Varmepumpe Fujitsu
- Varmepumpe Tesy
- Varmepumpe Dimplex
- Varmepumpe Nibe
- Varmepumpe Blaupunkt
- Varmepumpe Mitsubishi
- Varmepumpe Fisher And Paykel
- Varmepumpe REMKO
- Varmepumpe ATAG
- Varmepumpe Vivax
- Varmepumpe Wilfa
- Varmepumpe Remeha
- Varmepumpe Grundfos
- Varmepumpe Kospel
- Varmepumpe Junkers
- Varmepumpe Viessmann
- Varmepumpe Baxi
- Varmepumpe Vaillant
- Varmepumpe Nefit
- Varmepumpe Itho-Daalderop
- Varmepumpe Carrier
- Varmepumpe AWB
- Varmepumpe Ferroli
- Varmepumpe Waterco
- Varmepumpe Stiebel Eltron
- Varmepumpe De Dietrich
- Varmepumpe Fairland
- Varmepumpe Astralpool
- Varmepumpe Harmopool
- Varmepumpe Atlantic
- Varmepumpe Wilo
- Varmepumpe Maxicool
- Varmepumpe Wita
- Varmepumpe Armstrong
- Varmepumpe JANDY
- Varmepumpe MRCOOL
- Varmepumpe Orima
- Varmepumpe Hydro-Pro
- Varmepumpe Qlima
- Varmepumpe Thermor
- Varmepumpe Flojet
- Varmepumpe Elco
- Varmepumpe Alpha Innotec
- Varmepumpe Techneco
- Varmepumpe Calorex
- Varmepumpe Azuro
- Varmepumpe Zodiac
- Varmepumpe Dantherm
- Varmepumpe Weishaupt
- Varmepumpe Worcester
- Varmepumpe Comfortpool
Nyeste Varmepumpe Manualer
22 August 2025
21 August 2025
21 August 2025
21 August 2025
18 August 2025
18 August 2025
15 August 2025
9 August 2025
6 August 2025
6 August 2025