Danby DPAC12010H Bruksanvisning
Danby
luftkondisjonering
DPAC12010H
Les nedenfor 📖 manual på norsk for Danby DPAC12010H (20 sider) i kategorien luftkondisjonering. Denne guiden var nyttig for 6 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 3.5 brukere
Side 1/20

Owner’s Use and Care Guide
Guide d’utilisation et soins de Propriètaire
Model • Modèle
DPAC12010H
V1.12.09 JF
CAUTION: Read and
follow all safety rules
and operating
instructions before
first use of this
product.
MISE EN GARDE:
Veuillez lire
attentivement les
consignes de sécurité
et les directives
d’utilisation avant
l’utilisation initiale
de ce produit.
PORTABLE AIR CONDITIONER
Owner’s Use and Care Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 - 10
• Welcome
• Part Identification
• Important Safety Information
• Installation
• Operation
• Care and Maintenance
• Troubleshooting
• Warranty
CLIMATISEUR PORTATIF
Guide d’utilisation et soin de Propriètaire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 - 20
• Bienvenue
• Indentification de Partie
• Consignes de Sécurité Important
• Installation
• Fonctionnement
• Soins et Entretien
• Garantie
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE:
If the unit changes ownership, be sure this manual accompanies the unit.
CONSERVER CES INSTRUCTIONS POUR CONSULTATION ULTÉRIEURE:
En cas de revente du l’appareil, ce manuel doit être inclus avec l’appareil.
Danby Products Ltd, Guelph, Ontario Canada N1H 6Z9
Danby Products Inc, Findlay, Ohio USA 45840

Thank you for choosing a Danby Premiere appliance to provide you and your family with all of the
“Home Comfort” requirements of your home, cottage, or office. This Owner’s Use and Care Guide
will provide you with valuable information necessary for the proper care and maintenance of your
new appliance. If properly maintained, your Danby appliance will give you many years of trouble
free operation. Please take a few moments to read the instructions thoroughly and familiarize yourself
with all of the operational aspects of this appliance.
Your Danby Portable Air-Conditioner is a multi-functional room air-exchanging, air-processing
appliance, designed to offer you the functions of; Air Conditioning, Dehumidifying, and Independent
Fan. Each individual mode is featured with “oscillating” air swing capabilities. This unit can be
conveniently moved from room to room within your home and set up in just minutes. Imagine the
convenience of 4 Season Home Comfort at your fingertips, anywhere, anytime.
For easy reference, may we suggest you attach a copy of your sales slip/receipt to this page, along
with the following information, located on the manufacturers nameplate on the rear panel of the unit.
Model Number:
Serial Number:
Date of Purchase:
This information will be necessary if your unit requires servicing and/or for general inquiries. To contact a
Customer Service Representative, call Danby TOLL FREE: 1-800-26- (1-800-263-2629)
WELCOME
1

READ ALL SAFETY INFORMATION BEFORE USING
1) Check available power supply and resolve any wiring
problems BEFORE installation and operation of this unit.
All wiring must comply with local and national electrical
codes and be installed by a qualified electrician. If you have
any questions regarding the following instructions, contact a
qualified electrician.
2) This appliance draws 10.8 nameplate amps under Cooling
Mode and may be used in any properly wired, general
purpose 15 amp household grounded receptacle.
3) For your safety and protection, this unit is grounded through
the power cord plug when plugged into a matching wall
outlet. If you are not sure whether the wall outlets in your
home are properly grounded, please consult a qualified
electrician.
WARNING: Improper connection of the grounding plug can
result in risk of Fire, Electric Shock, and/or injury to Persons
associated with the appliance. Check with a qualified service
representative if in doubt that the appliance is properly grounded.
4) DO NOT USE PLUG ADAPTERS OR EXTENSION
CORDS WITH THIS UNIT. If it is necessary to use an
extension cord with this unit, use an approved “air
conditioner” extension cord only (available at most local
hardware stores).
5) To avoid the possibility of personal injury, always
disconnect the power supply to the unit before installing
and/or servicing.
TABLE 1
Suggested Individual Branch Circuit
Nameplate Amps *AWG Wire Size
10.8 16
AWG- American Wire Gauge
*Based on copper wire at 105°C temperature rating.
TABLE 2
Receptacle and Fuse Types
Rated Volts 125
Amps 15
Wall Outlet
Fuse Size 15
Time Delay Fuse Plug Type
(or Circuit Breaker)
Control Panel
Air Outlet
Signal Receptor
Castor
Air Intake
(Evaporator)
Handle
Air Intake Hose
Air Outlet Hose
Water Outlet Drain
Power Supply Cord
2
PART IDENTIFICATION
CAUTION: Do not leave this unit
unattended in a space where people or
animals that cannot react to a failed unit
are located. A failed unit can cause
extreme overheating or death in such an
enclosed, unattended space.
ELECTRICAL
SPECIFICATIONS
IMPORTANT SAFETY INFORMATION
Produkspesifikasjoner
Merke: | Danby |
Kategori: | luftkondisjonering |
Modell: | DPAC12010H |
Trenger du hjelp?
Hvis du trenger hjelp med Danby DPAC12010H still et spørsmål nedenfor, og andre brukere vil svare deg
luftkondisjonering Danby Manualer
18 August 2025
18 August 2025
18 August 2025
18 August 2025
18 August 2025
18 August 2025
18 August 2025
17 August 2025
17 August 2025
17 August 2025
luftkondisjonering Manualer
- MSW
- Samsung
- Hitachi
- Ivation
- Manta
- Midea
- Daikin
- ElectriQ
- Hisense
- Primo
- Eurom
- Tripp Lite
- Trotec
- Apc
- Ufesa
Nyeste luftkondisjonering Manualer
27 September 2025
27 September 2025
27 September 2025
27 September 2025
26 September 2025
24 September 2025
23 September 2025
23 September 2025
23 September 2025
23 September 2025