Drayton HTS3 Bruksanvisning

Les nedenfor 📖 manual på norsk for Drayton HTS3 (2 sider) i kategorien Termostat. Denne guiden var nyttig for 33 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 17 brukere

Side 1/2
06490287001
ISS
A
HTS3 Cylinder
Thermostat
Installation instructions
Technical Data
Setting Range
Differential
8°C approx.
Switch rating
3 (1) A 230V ac
Switch type
SPDT
Earth
Double insulated
not required
Connections
Ccommon
1call
2satis ed
Fixing
Plastic-coated spring wire
with hook and eyelet.
Cylinder thermostats
Make Model Common Call Satised
HTS 3 C 1 2
Lifestyle HTS 2 R B Y
Danfoss
Randall
AT (CN4) 1 2 3
ATAG
CS 1/CS 2 1
2 3
Honeywell L641A C 1 2
Landis
& Gyr
RAM 1 1 2 3
Potterton
Myson
PTT 1 L H C
Sunvic 1452/
SA2451
3 1 2
Sopac SAY C 1 2
Smiths SCT 1 1 2 3
Tower CS 1 R B Y
Barlo CT 1 R B Y
Pollution Degree
2
Ball pressure
Test Temperature
110ºC
Rated impulse
voltage
2.5kV
20 / /E14 35 U Low Voltage Directive
2011/65/E Restriction of the Use of CertainU
Hazardous Substances (RoHS)
Energy Class
I = 1% (Acc. EU
811/2013, 812/2013,
813/2013, 814/2013)
Conforms to the essential requirements
of the following directives:
20 4/ /E – Electromagnetic ompatibility130U C Directive
What is a cylinder thermostat?
...an explanation for householders
A cylinder thermostat switches on and off the heat supply from the boiler
to the hot-water cylinder. It works by sensing the temperature of the water
inside the cylinder, switching on the water heating when the temperature
falls below the thermostat setting, and switching it off once this set
temperature has been reached.
Turning a cylinder thermostat to a higher setting will not make the water
heat up any faster. How quickly the water heats up depends on the
design of the heating system, for example, the size of boiler and the heat
exchanger inside the cylinder.
The water heating will not work if a time switch or programmer has
switched it off. And the cylinder thermostat will not always switch the
boiler off, because the boiler sometimes needs to heat the radiators.
Cylinder thermostats are usually fitted between one quarter and one third
of the way up the cylinder. The cylinder thermostat will have a temperature
scale marked on it, and it should be set at between 60C and 65C, then left
to do its job. This temperature is high enough to kill off harmful bacteria in
the water, but raising the temperature of the stored hot water any higher
will result in wasted energy and increase the risk of scalding.
If you have a boiler control thermostat, it should always be set to a
higher temperature than that of the cylinder thermostat. In most boilers,
a single boiler thermostat controls the temperature of water sent to both
the cylinder and radiators, although in some there are two separate
20 / /E12 19 U WEEE Directive
ATAG
ATAG
ATAG
ATAGATAG
Technology Ltd
Technology Ltd
Technology Ltd
Technology Ltd Technology Ltd
80 Churchill Square Business Centre
Kings Hill
West Malling
Kent
M 19 4YUE
Technical Tel: 0800 254 5065
Email: technical@atagheating.co.uk
Website: www.atagheating.co.uk

Produkspesifikasjoner

Merke: Drayton
Kategori: Termostat
Modell: HTS3

Trenger du hjelp?

Hvis du trenger hjelp med Drayton HTS3 still et spørsmål nedenfor, og andre brukere vil svare deg