Extron PI 115 Bruksanvisning
                    Extron
                    
                    Ikke kategorisert
                    
                    PI 115
                
                                
                
                
                                
                Les nedenfor 📖 manual på norsk for Extron PI 115 (2 sider) i kategorien Ikke kategorisert. Denne guiden var nyttig for 31 personer og ble vurdert med 4.3 stjerner i gjennomsnitt av 16 brukere
                        Side 1/2
                    
                    
                    
1
PI 115 Power Injector • Installation Guide
The Extron PI 115 Power Injector supplies power to one Extron PoE compatible 
product. This guide provides instructions for an experienced installer to install and 
connect the PI 115.
Rear Panel Front Panel
LAN + PWR OUT
PI 115
LAN
100/240V ,50-60Hz~
0.45A MAX
PWR
Installation
Step 1 — Mounting
ATTENTION:
•  These power supplies are not suitable for use in air handling spaces or in 
wall cavities. The power supply must be located within the vicinity of the 
Extron AV equipment in an ordinary location with pollution degree2, and 
secured to an equipment rack within a dedicated closet, podium, or desk.
•  Ces sources d’alimentation ne sont pas appropriées pour une utilisation 
dans les espaces d’aération ou dans les cavités murales. Cette source 
d’alimentation doit être située à proximité de l’équipement audiovisuel 
d’Extron, dans un endroit ordinaire avec une pollution IEC1010 degré2, 
et xé à un équipement de rack au sein d’un placard, d’une estrade ou 
d’un bureau qui lui est dédié.
•  The installation must be in accordance with the applicable provisions 
of National Electrical Code ANSI/NFPA70, article725 and Canadian 
Electrical Code part1, section16. The power supply must not be 
permanently xed to building or similar structure.
•  Cette installation doit toujours être en accord avec les mesures qui 
s’applique au National Electrical Code ANSI/NFPA70, article725, et au 
Canadian Electrical Code, partie1, section16. La source d’alimentation 
ne devra pas être xée de façon permanente à une structure de bâtiment 
ou à une structure similaire.
•  The PI 115 is intended for indoor use only. It is to be connected only to 
networks or circuits that are not routed to the outside plant or building.
•  Le PI 115 est destinée à une utilisation en intérieur uniquement. Elle doit 
être connectée seulement à des réseaux ou des circuits qui ne sont pas 
routés au réseau ou au bâtiment extérieur.
Using the ZipClip 200
To attach the power injector to the ZipClip 200 mounting clip:
1.  Insert the bottom of the power injector down into the clip, starting with one 
end.
2.  Pivot the other end down and press until the clip  
snaps into place.
To remove the power injector from the ZipClip:
1.  Press the tab (
1
) on the ZipClip.
2.  Pivot the power injector and lift it out of the 
ZipClip (
2
).
To fasten the tie wraps for cable strain relief:
1.  Attach the power injector to the  
ZipClip 200 mounting clip as described 
previously.
2.  Fasten the power output cords to the 
ZipClip base.
a.  Insert tie wraps along the notches on the 
side of the power injector and through the tie 
wrap anchor points on the ZipClip, then around 
the cord.
b.  Connect and pull the tie wraps until they are 
secure. Do not over tighten.
Mounting to a Rack Shelf
These power supplies are one-quarter rack 
wide. Up to four power supplies can be 
mounted side by side directly onto a rack shelf.
1.  Align the threaded holes in 
the bottom of the power 
injector with the holes 
in an Extron rack shelf. 
Fasten the supply to the 
shelf with two  
4-40 x 3/16 inch screws 
(
1
) as shown on the 
right.
2.  Bolt the rack shelf to the rack (
2
).
Furniture Mounting
1.  Attach the ZipClip to the furniture 
using two or more wood screws 
(included) as shown at right (
1
). 
Make sure the clip is oriented with the 
appropriate side facing the mounting 
surface and with the tab accessible 
from the front of the furniture.
2.  Insert the power injector into the 
ZipClip as described previously and 
press to snap it into place (
2
).
(2) 4-40 x 3/16"
Sc srew
RSB  312
Rack Shelf
Ra  Mountedck
1
2
E
E
E
E
E
E
E
E
E
E
LAN PWR OUT
LAN
0.45A MAX
PW
Tie Wrap
LAN
 P WR OUT
PI 115
L
AN
100/240V 
~
,5 0-60Hz
0.4 5A  MAX
P
WR
1
2
PI115
ZipClip 200
Mounting to Rack Rails Using a ZipClip
1.  Fasten the ZipClip 200 mounting clip to a rack rail 
using two rack screws as shown in the diagram 
on the right (
1
).
2.  Insert the power injector into the ZipClip as 
described previously and press to snap it into 
place (
2
).
ZipClip 200
Ba  of Rackck
1
2
1
2
NOTE: Do not use two power injectors on the same cable run to remotely 
power the transmitter and receiver. The diagram below shows this type of 
application, which is not recommended by Extron.
LAN + PWR OUT
PI 115
LAN
100/240V  50-60Hz~ ,
0.45A MAX
PWR
LAN + PWR OUT
PI 115
LAN
100/240V  50-6~ ,
0.45A MAX
PWR
LAN
SIG                 LINK
XTP IN
POWER
12V
HDMI
1.4A MAX
Rx GTx
RS-232  IR
RxTx
−+ −+
L R
1
2
OVER  XTP
AUDIO
OFF
ON
S/PDIF
RESET
RS-232
Tx Rx G
REMOTE
RELAYSOUTPUTS
AUDIO
POWER
12V
HDMI
0.7A MAX
Rx GTx
RS-232  IR
RxTx
−+
−+
L R
LOOP THRU
RESET
AUDIO
OFF
ON
AUDIO
XTP T HD 4K
LAN
SIG             LINK
XTP OUT
INPUTS
OVER  XTP
CATx
XTP SR   HD 4K
CATx
XTP T HD 4K
PI  511
PI  511
NOT RECOMMENDED
CATx
Important Safety Instructions
This symbol, when used on the product, 
is intended to alert the user of important 
operating and maintenance (servicing) 
instructions in the literature provided with the 
equipment.
This symbol, when used on the product, is 
intended to alert the user of the presence 
of uninsulated dangerous voltage within the 
product enclosure that may present a risk of 
electric shock.
  •  Read these instructions.
  •  Keep these instructions.
  •  Heed all warnings.
  •  Follow all instructions.
  •  Do not use this apparatus near water.
  •  Clean only with a dry cloth.
  •  Do not block any ventilation openings. Install in accordance with the 
manufacturer instructions.
  •  Do not install near any heat sources such as radiators, heat registers, 
stoves, or other apparatus (including amplifiers) that produce heat.
  •  Do not defeat the safety purpose of the polarized or grounding-type 
plug. A polarized plug has two blades with one wider than the other.  A 
grounding type plug has two blades and a third grounding prong. The 
wide blade or the third prong is provided for your safety. If the provided 
plug does not fit into your outlet, consult an electrician for replacement 
of the obsolete outlet.
  •  Protect the power cord from being walked on or pinched, particularly at 
plugs, convenience receptacles, and the point where they exit from the 
apparatus.
  •  Use only attachments and accessories specified by the manufacturer.
  •  Unplug this device apparatus during lightning storms or when unused 
for long periods of time.
CAUTION:  Risk of electric shock. To reduce 
the risk of fire or electric shock, do not expose this apparatus to 
rain, moisture, dripping, splashing, or objects filled with liquids.
ATTENTION :  Risque de choc électrique: Afin 
de réduire les risques d’incendie ou de choc électrique, protégez 
cet appareil de la pluie ou de l’humidité. Cet appareil doit être 
conservé à l’abri des éclaboussures et des projections, et aucun 
objet contenant un liquide, tel qu’un vase, ne doit être posé sur 
l’appareil.
Refer all servicing to qualified service personnel. Servicing is required 
when the apparatus has been damaged in any way, such as when 
the power-supply cord or plug is damaged, liquid has been spilled 
or objects have fallen into the apparatus, the apparatus has been 
exposed to rain or moisture, does not operate normally, or has been 
dropped.
ATTENTION:
•  This apparatus is a Class I product. This product must be 
connected to a mains socket outlet with a protective earthing 
connection.
•  Cet appareil est un produit de Classe1. Ce produit doit 
être connecté à une prise femelle secteur équipée d’une 
connexion de mise à la terre.
The mains plug is used as the disconnect device and shall remain readily 
operable.
To prevent the risk of shock, do not attempt to service this equipment 
yourself because opening or removing covers may expose you to 
dangerous voltage or other hazards.
ATTENTION:
Power sources • This equipment should be operated only from 
the power source indicated on the product. This equipment is 
intended to be used with a main power system with a grounded 
(neutral) conductor. The third (grounding) pin is a safety feature. 
Do not attempt to bypass or disable it.
[Source d’alimentation] • Ce matériel ne devrait être alimenté 
qu’à partir de la source d’alimentation stipulée sur le produit. 
Ce matériel est prévu pour être relié à un circuit d’alimentation 
général doté d’un conducteur (neutre) mis à la terre. La troisième 
broche (de terre) est un composant de sécurité. N’essayez pas 
de l’éviter ou de la désactiver.
Power disconnection • To remove power from the equipment safely, 
remove all power cords from the rear of the equipment, or the 
desktop power module (if detachable), or from the power source 
receptacle (wall plug).
Déconnection de l’alimentation • Pour déconnecter le matériel de 
sa source d’alimentation en toute sécurité, débranchez tous les 
cordons d’alimentation de l’arrière du matériel ou débranchez 
l’adaptateur secteur (si débranchable) ou de la prise secteur 
(prise murale).
LED Indicators
A 
Front panel power LED indicator — 
Lights to indicate the PI 115 is  
receiving power.
B 
Rear panel PWR LED indicator — 
Indicates various power states of the 
connected endpoints (see the table below).
LED State Port Status
Unlit The endpoint is not connected or cannot be powered.
Lit The endpoint is receiving power from the PI 115.
Blinking There is a power overload fault, or power allocation is exceeded.
Step 2 — Cabling
For the best performance, see Twisted Pair Recommendations on page 2.
1.  Connect a network switch or an Extron 
twisted pair transmitter product to the 
LAN port (
A
) of the power injector 
using a straight-through cable. The 
device plugged into this connector 
needs to be powered by a local power 
source.
2.  Connect an Extron PoE compatible 
product that requires remote power 
to the     port (LAN+PWR OUT
B
) using  
a straight-through cable.
3.  Connect AC power to the PI115 (
C
).
LAN + PWR OUT
PI 115
LAN
100/240V   ,50-60Hz~
0.45A MAX
PWR
A
B
LAN + PWR OUT
PI 115
LAN
100/240V ,50-60Hz
0.45A MAX
PWR
To network or 
XTP device
To Extron PoE 
compatible device 
that can be powered 
via  EPo
A
B
C
Produkspesifikasjoner
| Merke: | Extron | 
| Kategori: | Ikke kategorisert | 
| Modell: | PI 115 | 
Trenger du hjelp?
Hvis du trenger hjelp med Extron PI 115 still et spørsmål nedenfor, og andre brukere vil svare deg
Ikke kategorisert Extron Manualer
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         12 Mars 2025
                        
                    
                                                            
                        
                         11 Mars 2025
                        
                    
                                                            
                        
                         25 Februar 2025
                        
                    
                                                            
                        
                         25 Februar 2025
                        
                    
                                                            
                        
                         25 Februar 2025
                        
                    
                                                            
                        
                         25 Februar 2025
                        
                    
                                                            Ikke kategorisert Manualer
- Livall
- Manta
- Arco
- Boehringer Ingelheim
- ETA
- Scala
- Hovicon
- Krups
- BSS Audio
- Stiebel Eltron
- Kali Audio
- Statron
- Plantronics
- Elation
- Gossen Metrawatt
Nyeste Ikke kategorisert Manualer
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025