Faber INPL3619SSNB-B Bruksanvisning
Faber
eksoshette
INPL3619SSNB-B
Les nedenfor 📖 manual på norsk for Faber INPL3619SSNB-B (60 sider) i kategorien eksoshette. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/60

INPL3019SSNB-B
INPL3619SSNB-B
INPL3622SSNB-B
INPL4219SSNB-B
INPL4819SSNB-B
INPL4822SSNB-B
Installation Instructions
Use and Care Information
Instructions d'installation
Utilisez et d'entretien
Instrucciones de instalación
Información de uso y cuidado
INCA PRO PLUS

2
READ AND SAVE THESE INSTRUCTIONS BEFORE YOU
START INSTALLING THIS RANGEHOOD
WARNING: - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause smoking and
greasy spillovers that may ignite. Heat oils slowly on low or medium setting.
b)AlwaysturnhoodONwhencookingathighheatorwhenambeingfood(i.e.Crepes
Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan
orlter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING: - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
a)SMOTHERFLAMESwithaclose-ttinglid,cookiesheet,ormetaltray,thenturnotheburner.
BECAREFULTOPREVENTBURNS.IftheamesdonotgooutimmediatelyEVACUATE
AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will
result.
d) Use an extinguisher ONLY if:
1. You know you have a Class ABC extinguisher, and you already know how to operate it.
2. Thereissmallandcontainedintheareawhereitstarted.
3. Theredepartmentisbeingcalled.
4. Youcanghttherewithyourbacktoanexit.
* Based on "Kitchen Firesafety Tips" published by NFPA
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan
with any solid-state speed control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PER-
SONS, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have any questions,
contact the manufacturer.
b)Beforeservicingorcleaningunit,switchpoweroatservicepanelandlocktheservice
disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or
Explosive Materials and Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
1. InstallationWorkAndElectricalWiringMustBeDoneByQualiedPerson(s)InAccor-
dance With All Applicable Codes And Standards, Including Fire-Rated Construction.
2. Sucientairisneededforpropercombustionandexhaustingofgasesthrough
theue(chimney)offuelburningequipmenttopreventbackdrafting.Followthe
heating equipment manufacturer's guideline and safety standards such as those

3
ALL WALL AND FLOOR OPENINGS WHERE THE RANGEHOOD IS INSTALLED
MUST BE SEALED.
This rangehood requires at least 24" of clearance between the bottom of the rangehood and the
cooking surface or countertop. This hood has been approved by UL at this distance from the cooktop.
This minimum clearance may be higher depending on local building codes. For gas cooktops and
combination ranges, a minimum of 30" is recommended and may be required.
Overhead cabinets on both sides of this unit must be a minimum of 18" above the cooking surface
or countertop. Consult the cooktop or range installation instructions given by the manufacturer
before making any cutouts.
MOBILE HOME INSTALLATION The installation of this rangehood must conform to the Manufactured
Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard
for Mobile Home Construction and Safety, Title 24, HUD, Part 280). See Electrical Requirements.
• Venting system MUST terminate outside the home.
• DO NOT terminate the ductwork in an attic or other enclosed space.
• DO NOT use 4" laundry-type wall caps.
• Flexible-type ductwork is not recommended.
• DO NOT obstruct the ow of combustion and ventilation air.
• Failure to follow venting requirements may result in a re.
WARNING
!
VENTING REQUIREMENTS
Determine which venting method is best for your application. Ductwork can extend either through the
wall or the roof.
The length of the ductwork and the number of elbows should be kept to a minimum to provide ecient
performance. The size of the ductwork should be uniform. Do not install two elbows together. Use
duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or oor opening
around the cap.
Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air
turbulence that greatly reduces performance.
Make sure there is proper clearance within the wall or oor for exhaust duct before making cutouts.
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting
frame must be constructed.
WARNING - To Reduce The Risk Of Fire, Use Only Metal Ductwork.
CAUTION-Toreduceriskofreandtoproperlyexhaustair,besuretoductairoutside–Do
not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
publishedbytheNationalFireProtectionAssociation(NFPA),andtheAmerican
SocietyforHeating,RefrigerationandAirConditioningEngineers(ASHRAE),and
the local code authorities.
3. When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
4. Ducted fans must always be vented to the outdoors.
Produkspesifikasjoner
Merke: | Faber |
Kategori: | eksoshette |
Modell: | INPL3619SSNB-B |
Trenger du hjelp?
Hvis du trenger hjelp med Faber INPL3619SSNB-B still et spørsmål nedenfor, og andre brukere vil svare deg
eksoshette Faber Manualer
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025
12 September 2025
eksoshette Manualer
- eksoshette Teka
- eksoshette Miele
- eksoshette Whirlpool
- eksoshette Etna
- eksoshette Haier
- eksoshette KitchenAid
- eksoshette Pelgrim
- eksoshette Bosch
- eksoshette BEKO
- eksoshette Exquisit
- eksoshette Grundig
- eksoshette Café
- eksoshette Balay
- eksoshette Siemens
- eksoshette Smeg
- eksoshette Thermex
- eksoshette Hotpoint
- eksoshette Amica
- eksoshette IKEA
- eksoshette AEG
- eksoshette Rosieres
- eksoshette Inventum
- eksoshette Artusi
- eksoshette Cecotec
- eksoshette Samsung
- eksoshette Neff
- eksoshette Best
- eksoshette Midea
- eksoshette Franke
- eksoshette Candy
- eksoshette Trade-Wind
- eksoshette Gorenje
- eksoshette Toolcraft
- eksoshette Gram
- eksoshette Vox
- eksoshette Bertazzoni
- eksoshette Coyote
- eksoshette XO
- eksoshette Ciarra
- eksoshette Omega
- eksoshette Fisher Paykel
- eksoshette Fulgor Milano
- eksoshette Boretti
- eksoshette Indesit
- eksoshette Asko
- eksoshette Dacor
- eksoshette Respekta
- eksoshette Philco
- eksoshette Jenn-Air
- eksoshette Klarstein
- eksoshette ATAG
- eksoshette V-Zug
- eksoshette Cata
- eksoshette Witt
- eksoshette Glem Gas
- eksoshette Hansa
- eksoshette Thor
- eksoshette Vent-A-Hood
- eksoshette Fagor
- eksoshette Edesa
- eksoshette Wolf
- eksoshette Ilve
- eksoshette Rommer
- eksoshette Svan
- eksoshette Corberó
- eksoshette Broan
- eksoshette Thermador
- eksoshette JennAir
- eksoshette Kaiser
- eksoshette NuTone
- eksoshette Blomberg
- eksoshette ZLine
- eksoshette De Dietrich
- eksoshette Hanseatic
- eksoshette Oranier
- eksoshette Berbel
- eksoshette Turbo Air
- eksoshette Ariston Thermo
- eksoshette InAlto
- eksoshette BlueStar
- eksoshette Roblin
- eksoshette Seenergy
- eksoshette Vollrath
- eksoshette Premier
Nyeste eksoshette Manualer
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025
13 September 2025