Festo VAD-MYB-1/8 Bruksanvisning
Les nedenfor 📖 manual på norsk for Festo VAD-MYB-1/8 (6 sider) i kategorien genrator. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/6

332 852
Bedienungsanleitung
elektrisch
Typ VAD- .
und
VAD-..:-I-...
Operating instructions
Vacuum suction
generator electrical
Type VAD
.
and
VAD-...-I-...
1
2
Conditions regarding the use of Festo
equipment.
This is important for reasons of safety
that only properly
and
qualied personnel use this equipment.
2.
equipment should only be used within the
detailed
the
observance of
the technical
should be ensured at all times.
Correctly prepared compressed
should be used at
all
When
the equipment and thereafter, the
shall
the place of use
taken
consideration.
4. If the equipment is
system
used
safety devices
the Customer shall ensure
that
and local safety laws and
served.
5. Should you
further
please contact
your local
These instructions important. Please keep them in
D i e
fur
Was ist beim
von Festo Elementen
die Beach-
di e
beachten?
Es
auf den
mit
die
am
i m
die
die

Operating parts and connections
1. Bedienteile und
Mounting holes
@Attachment threads
Vacuum port
Supply port
Manual override (vacuum)
Connection for vacuum
Connection for ejecting impulse/
electrical
Manual override (ejecting impulse)
Silencer
Bohrung
Befestigung
Gewinde
Befestigung
Handhilfsbetatigung
Elektrischer
Vakuumsignal
Elektrischer
Abwurfimpuls
Handhilfsbetatigung (Abwurfimpuls)
data
2. Technische Daten
Solenoid valve
Silencer
.

3. Transport and storage 3. Transport und Lagerung
VAD should be stored between -20 and
Lagern Sie die VAD nur zwischen -20
only, as failure to do so can impair
sonst
die Funktionsfahigkeit
functioning.
werden.
4. Installation
4.1 Mechanical details
Position
unit in such a way that the
operating parts and ports can be freely ac-
cessed at all times (see Care and mainten-
ance).
4. Einbau
4.1 mechanisch
Supply port
should have an inside diame-
ter of approx.3 times that of the
nozzle (see “trouble shooting”).
Plazieren Sie die VAD so,
Sie die
dienteile und
stets erreichen
(siehe Wartung und
Ver w ende n
am
von ca. 3
(siehe
hinweise).
4.2 Electrical details
4.2 elektrisch
Please ensure that the switching voltage is
24
10%. If the permissible switching
voltage is exceeded, the solenoid valve can
be damaged.
Wiring
l Switching signal for vacuum generation
on solenoid valve
Sie
die Schaltspannung
24
10% (DC)
der
Schaltspannung
die
Magnetspule
werden.
Beschalten
l Schaltsignal fur Vakuumerzeugung an
Magnetventil
Wiring
l Switching signal forvacuum generation to
solenoid facing away from silencer.
l Switching signal for ejecting impulse to
solenoid on silencer side.
l Schaltsignal
Vakuumerzeugung an
schalldampferabgewandtes
til.
l Schaltsignal fur Abwurfmutter an
5. Operation and function
The solenoid valves must always be
gised alternatively to prevent any overlap
between vacuum generation and ejecting
impulse.
If both functions occur simultaneously, nei-
ther will be fully eective.
dampferseitiges Magnetventil.
5.
und Betrieb
. . . .
Sie die
der Magnetspulen
immer im Wechsel an,
keine
schneidungen zwischen Vakuumerzeugung
Abwurfimpuls auftreten.
Treten beide Funktionen gleichzeitig
sind beide
wirksam.
Produkspesifikasjoner
Merke: | Festo |
Kategori: | genrator |
Modell: | VAD-MYB-1/8 |
Trenger du hjelp?
Hvis du trenger hjelp med Festo VAD-MYB-1/8 still et spørsmål nedenfor, og andre brukere vil svare deg
genrator Festo Manualer
6 August 2025
genrator Manualer
Nyeste genrator Manualer
7 August 2025
5 August 2025
3 August 2025
3 August 2025
3 August 2025