Generac G0063771 Bruksanvisning
                    Generac
                    
                    SLR kamera
                    
                    G0063771
                
                                
                
                
                                
                Les nedenfor 📖 manual på norsk for Generac G0063771 (8 sider) i kategorien SLR kamera. Denne guiden var nyttig for 23 personer og ble vurdert med 3.9 stjerner i gjennomsnitt av 12 brukere
                        Side 1/8
                    
                    
                    
1 
Installation and Operating Instructions 
MANUAL TRANSFER SWITCH MODELS 6375 and 6377 
WARNING:  Generac
®
 transfer switches should be installed by a professional electrician familiar with electrical wiring and codes, and experienced in working with generators.  Generac 
accepts no responsibility for accidents, damages or personal injury caused by incorrect installation.  This transfer switch is intended for surface mounting OUTDOORS only.  Our transfer 
switches are UL listed to UL 1008 and meet the criteria of National Electrical code Article 702.6 for Optional Standby Systems.  CAUTION:  If using the generator and transfer switch for 
larger appliances, such as electric water heaters, clothes dryers, electric ranges and small air conditioners, check the labels on the appliances to be sure they do NOT exceed the rating 
of the generator.  No appliance should have an amperage rating that exceeds the individual breaker rating in the transfer switch (20 or 30 amps).  CALIFORNIA PROPOSITION 65 
WARNING:  Engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects and other reproductive harm.  This product may contain or 
emit chemicals known to cause cancer, birth defects and other reproductive harm. 
Thank you for purchasing a Generac Transfer Switch to safely connect a portable 
generator to a single circuit in your home or business (single phase only) for standby 
power applications.  Product features include: 
• Generator Main and Utility Mains mechanically interlocked to prevent utility and generator from 
feeding circuit at the same time 
• This transfer switch is intended to be surface mounted next to an existing load center and wired to 
one circuit breaker in the main panel. 
Tools and Items Needed for Installation:  
• 1/4” and 11/32 nut drivers 
• Straight blade and Phillips screwdriver 
• Electric drill, anchors and screws to mount transfer switch to wall 
• Wire cutter/stripper 
• Wire connectors 
• Power Cord to connect generator to switch 
              Model 6375 Shown 
TABLE 1 - SPECIFICATIONS 
MODEL:  6375
6377
Max Generator Size in Watts 
1875  7500 
Max Amps  
15 amps @ 125 volts  30 amps @ 125/250 volts 
NEMA Configuration of Power Inlet 
5-15  L14-30 
Voltage 
125 Volts  125/250 Volts 
NEMA Type Enclosure  
3R – Outdoor   3R – Outdoor  
Phase 
1  1 
Minimum Gauge Cord Size 
12/3 AWG  10/4 
STEP 1:  INSTALLATION PROCEDURE: 
HAZARDOUS VOLTAGES ARE PRESENT INSIDE TRANSFER SWITCH ENCLOSURES THAT CAN CAUSE DEATH OR SEVERE PERSONAL INJURY.  FOLLOW PROPER INSTALLATION, 
OPERATION AND MAINTENANCE PROCEDURES TO AVOID HAZARDOUS VOLTAGES.  TURN OFF THE MAIN CIRCUIT BREAKER IN THE LOAD CENTER BEFORE STARTING INSTALLATION.  
Model 6375 – 15 amp Furnace Transfer Switch 
1. Furnace transfer switch can be installed to the left or right si 3. Trial fit the unit, holding ude of load center.  See Figure  p to the wall about 18” from the 
center of the load center, and mark the location of the transfer switch and end of harness at load center. 
2. Remove the load center cover.  CAUTION: dangerous voltages present inside load center. Locate and remove a ½” KO from the bottom of the load 
center where marked in Step 1.  Insert harness wires from transfer switch thru KO and install conduit fitting. 
3. Remove and retain the two screws that secure interior assembly to the transfer switch enclosure. 
4. Lift and pull out interior assembly to provide access to the four (4) mounting holes at the back of the enclosure.  Mount transfer switch enclosure in 
desired position using installer-provided fasteners through the four (4) mounting holes in back of enclosure.  Re-install interior assembly into enclosure 
(be sure not to pinch any wires between the enclosure and interior assembly) by hooking the top of the interior assembly deadfront over the studs on 
the inside of the enclosure and securing the interior assembly to the enclosure with the two screws removed in Step 3.  You are now ready to connect 
the transfer switch wires to the desired circuit inside the load center. 
5. Turn OFF the circuit breaker in the load center that you want to connect to the transfer switch.  Loosen the screw that secures the wire into the circuit 
breaker and remove the wire from the circuit breaker. 
6. Insert the RED (UTIL) wire from the transfer switch into the circuit breaker and tighten screw. 
7. Using a wire connector, connect the wire removed from the circuit breaker in step 5 with the BLACK (LOAD) wire coming from the transfer switch. 
8. Insert and tighten the WHITE (neutral) wire from the transfer switch into the NEUTRAL bar in the load center.  Insert and tighten the GREEN (ground) 
wire from the transfer switch into the GROUND bar in the load center.  If there is no ground bar, insert and tighten it into the NEUTRAL bar.  
9. Reinstall load center cover.  Turn on circuit breaker turned off in step 5.  Transfer switch is now ready for testing and operation. 
Produkspesifikasjoner
| Merke: | Generac | 
| Kategori: | SLR kamera | 
| Modell: | G0063771 | 
Trenger du hjelp?
Hvis du trenger hjelp med Generac G0063771 still et spørsmål nedenfor, og andre brukere vil svare deg
SLR kamera Generac Manualer
                        
                         16 Oktober 2024
                        
                    
                                                            
                        
                         16 Oktober 2024
                        
                    
                                                            
                        
                         16 Oktober 2024
                        
                    
                                                            
                        
                         16 Oktober 2024
                        
                    
                                                            
                        
                         16 Oktober 2024
                        
                    
                                                            SLR kamera Manualer
- Tamron
- Kern
- Lucide
- PUR
- Berker
- Toro
- Interstuhl
- Segway
- Hover-1
- Atlona
- Samsung
- Sime
- BOB Gear
- IPEGA
- Genesis
Nyeste SLR kamera Manualer
                        
                         16 August 2025
                        
                    
                                                            
                        
                         16 August 2025
                        
                    
                                                            
                        
                         5 Mars 2025
                        
                    
                                                            
                        
                         5 Mars 2025
                        
                    
                                                            
                        
                         5 Mars 2025
                        
                    
                                                            
                        
                         5 Mars 2025
                        
                    
                                                            
                        
                         5 Mars 2025
                        
                    
                                                            
                        
                         5 Mars 2025
                        
                    
                                                            
                        
                         5 Mars 2025
                        
                    
                                                            
                        
                         5 Mars 2025