Side 1/2

1.
2.
(1)Front panel
(2)Touch button
(3)LCD screen
(4)LED indicator
(5)Mounting bracket
(6)Heat sink
(7)DC switch
(8)PV terminal
(9)RS485 port (10)USB port
(11)Vent valve (12)AC terminal
1.This document is for quick installation guidance only, please refer to User Manual for more details.
2. Growatt shall not be liable for any damage resulting from unproper installation.
Note:
MID 17-40KTL3-X Quick Guide
Note:
1.When drilling holes in the wall, avoid water and electricity pipes, otherwise it may cause danger.
Overview
Installation
System overview
2.1 Installation requirements
2.2 Wall mounting
2.3 Communication module installation
Inverter side
Inverter side
Inverter side
Inverter side
▲Up
UninstallInstall
3.
Electrical connection
Please prepare the cable before connecting as follows.
1
2
3
4
Cable name
PV input wire
Type
four or five polychromatic
multi-core copper wires
PV wire(such as PV1-F)
RS485
Recommend model
16mm² - 20mm²
16mm² - 20mm²
4mm - 6mm² ²
/
No.
Communicatio
wire
AC output wire
grounding wire
Protective
Single multi-core
yellow-green wire
1.Please make sure all switches are in “OFF”
position before wiring. For personal safety,
please do not operate with electricity.
2.If the diameter of the cable does not match
the terminal, or the cable is aluminum wire,
please contact our after-sales personnel.
Note:
3.1 Grounding
Connect to the inverter
side.
It is recommended to use 16-20mm²
cable.
Install the AC side water
proof cover.
3.2 AC output connection
PE
inverter side
10-12mm
3.3 DC connection
3.3.1 PV input terminal installation
230
218
579
240 133
433
237
≥500mm
≥300mm
≥500mm
≥500mm
Noted:Waterproof must be blocked
with fireproof mud to prevent water.
Keep the
bracket
installed
horizontally.
8- 10mm
1
2
3
4
5
4mm - 6mm² ²
4mm - 6mm² ²
Positive metal terminal
Positive metal terminal
Negative metal terminal
Negative metal terminal
Negative metal terminal
Please make sure the cable can not be
pulled out after pressing.
Pull the PV cable make sure there
is no loose or shaking.
Make sure the cable polarity is
correct and voltage is less than
1100V.
1
5
6
7
811 12109
2
3
4
Produkspesifikasjoner
| Merke: | Growatt |
| Kategori: | Ikke kategorisert |
| Modell: | MID 17-40KTL3-X |
Trenger du hjelp?
Hvis du trenger hjelp med Growatt MID 17-40KTL3-X still et spørsmål nedenfor, og andre brukere vil svare deg
Ikke kategorisert Growatt Manualer
6 September 2025
6 September 2025
6 September 2025
6 September 2025
6 September 2025
6 September 2025
5 September 2025
5 September 2025
5 September 2025
5 September 2025
Ikke kategorisert Manualer
- HTW
- Harder & Steenbeck
- Lancom
- Beverage-Air
- Intesis
- Vitammy
- Sesame Street
- ACCU-CHEK
- EchoMaster
- Asus
- Beem
- GoXtreme
- Watson
- RDL
- Novation
Nyeste Ikke kategorisert Manualer
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025