MODEL: PF1222TB1 SUBPANEL 
TWO CIRCUIT POOL EQUIPMENT CONTROL WITH FREEZE AND HEATER PROTECTION
IN INDOOR/OUTDOOR ENCLOSURE
PANEL RATING: 60 AMP. 120/240 VOLT, 607 HZ. 
This Pool Equipment Control is designed to automatically operate the Filter Pump, Cleaner Pump and also to provide 
freeze protection for the pool equipment. Nevertheless this product is not intended to be a substitute for insulation, 
coverings, or maintenance.
THE FILTER PUMP TIME SWITCH is located in the upper
left side of the enclosure and operates the Filter Pump, as 
set by the trippers on the yellow dial, on a 24 hour 
schedule. For setting the schedule, refer to page 3 of this 
Manual.
THE FIREMAN SWITCH (heater protection mechanism) is
located next to the manual lever and its function is to stop 
the heating process 20 minutes before the Time Switch 
turns OFF the Filter Pump. By doing so, the circulating 
water cools the heat exchanger thus preventing excess
heat build-up.
THE CLEANER PUMP TIME SWITCH is located in the 
upper right side of the enclosure and operates the Cleaner 
Pump (Booster Pump). The trippers of this Time Switch 
should be set so that the operation of the Cleaner Pump 
falls within the operation of the Filter Pump. To avoid 
equipment damage, the two Time Switches are interlocked
and the Cleaner Pump would not operate unless the Filter 
Pump is already operating.
THE FREEZE PROTECTION THERMOSTAT is located in 
the lower left side of the enclosure and turns ON the Filter 
Pump when the air temperature (where the Control Panel 
is located) drops below the temperature set by the dial 
(between 33˚F and 42˚F).
INSTALLATION
OPERATION & 
SERVICE MANUAL
PF1000 SERIES
FREEZE PROTECTION CONTROLS
 Risk of drowning!
 Do not permit unsupervised children to use pool or spa.
  Close supervision of children required at all times.
DANGER
Turn power off at main panel before servicing this switch or the equipment  it controls. This control panel must be 
installed according to the National Electrical Code and local code requirements. Use MIN 75˚C Copper conductors ONLY. 
Install interchangeable circuit breakers with an interrupting current rating of 10000 symmetrical amperes, or higher. 
Follow manufacturers instructions for installing and testing of ground fault circuit breakers (GFCB) and interrupters 
(GFCI). Install only LISTED receptacle(s) and/or wiring device(s) inside the enclosure. When panel is outdoors, a LISTED 
rainproof cover must be installed over the wiring device in the side knockouts. This control should not be connected 
to any equipment which would cause bodily injury or property damage should it be activated unexpectedly. 
Reinstall safety guard after wiring.
 WARNING
Risk of  Fire or Electrical Shock
GENERAL INFORMATION
Produkspesifikasjoner
| Merke: | Intermatic | 
| Kategori: | Ikke kategorisert | 
| Modell: | PF1222TB1 | 
Trenger du hjelp?
Hvis du trenger hjelp med Intermatic PF1222TB1 still et spørsmål nedenfor, og andre brukere vil svare deg
Ikke kategorisert Intermatic Manualer
                        
                         9 September 2025
                        
                    
                                                            
                        
                         25 August 2025
                        
                    
                                                            
                        
                         24 August 2025
                        
                    
                                                            
                        
                         24 August 2025
                        
                    
                                                            
                        
                         4 August 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            Ikke kategorisert Manualer
- Vent-A-Hood
 - Guzzanti
 - Consul
 - Kerbl
 - Cylinda
 - Denon
 - Plasma Cloud
 - Helix
 - Celexon
 - Pressalit
 - Randell
 - Izzy
 - Nethix
 - JLab
 - Overmax
 
Nyeste Ikke kategorisert Manualer
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025
                        
                    
                                                            
                        
                         23 Oktober 2025