Controlling the Monitor with a computer (RS-232C)
You can control this monitor from a computer via -232C RS
(COM port) on the computer.
Communication conditions
Set the RS-232C communication settings on the computer to
match the monitor’s communication settings as follows:
Please refer to "Controlling the monitor via - " in the RS 232C
user manual.
Computer connection
Connect with RS- cross 232 cable between the computer’s
COM port (RS-232C connector) and the RS-232C input
terminal on the monitor.
To COM port
Computer
RS- cross cable 232
RS- (commercially available) 232C
input terminal
Baud rate
9600 bps
Data length
8 bits
Parity bit
None
Stop bit
1 bit
Flow control
None
3
TIPS
Controlling the Monitor with a computer (LAN)
You can control this monitor from a computer via network.
Please refer to "Controlling the monitor via LAN" in the
user manual.
The settings for the commands are set in "PC
CONTROL" on the web page.
Command-based control
You can control the monitor using S-Format
commands (see page 6) via terminal software and
other appropriate applications.
Read the manual for the terminal software for
detailed instructions.
Command setting for normal
communication
You can control user access by setting a login name and
password.
(1) Put a check mark on “HTTP SERVER” from
“NETWORK” > “NETWORK SERVICES”
(2) Press the DISPLAY button and check the IP
address of the monitor at the top left of the
screen.
(3) Input the address in the Web browser, then
login page is displayed.
(4) Register an administator password when you
log for the rst time From the next time in .
you log in, enter the password you registered
the rst time.
(5) Select PC CONTROL in the side menu.
(6) Set PC CONTROL to ENABLE
(7) Set S-FORMAT LOGIN AUTH to ENABLE
and set USER NAME and PASSPWORD if you
need.
(8) Press APPLY button.
Command control via normal
communication.
(1) Connect the computer to the monitor.
1. Specify the IP address and data port number
(Default setting: 10008) and connect the
computer to the monitor.
When connection has been established
successfully, [Login: ] is returned as response.
2. Send the user name.
Send [user name] + [ ].
When the transmission is successful,
[ Password: is returned as response. ]
3. Send the password.
Send [password] + [ ].
If the password is not set, send [ ].
When the transmission is successful, [OK
] is returned as response.
(2) Send commands to control the monitor.
The commands used are the same as those for
RS-232C. Refer to the communication
procedure (see page 4) for operation.
Usable commands are provided in S-Format
command table (see page 6).
(3) Disconnect the connection with the monitor
and quit the function.
1. Send [BYE ].
When the transmission is successful, [Goodbye
] is returned and the connection is disconnected.
You can access by settings of user name and password
registered in USER NAME / PASSWORD when “LOGIN
AUTH” is set to ENABLE.
When access control is not used, set LOGIN AUTH to
DISABLE. In this case send [blank] + [ ] as user name
and password.
If "AUTO LOGOUT" is ENABLE, the connection will be
disconnected after 15 minutes of no command
communication.
Up to 3 connections can be used at the same time.
TIPS