Power unit with decoupling coil.
At most 2 power units can be installed on each line.
CHARACTERISTICS.
• Consumption:
- 120 V: 700 mA
- 230 V: 450 mA
Dissipated power: 9 W
BUS output voltage: 29 V d.c. (SELV) with decoupling coil
AUX output voltage: 29 V d.c. (SELV)
Total max output current: 1280 mA (IBUS AUX + I )
Operating temperature: -5 °C - +45 °C (from inside)
8 modules of 17,5 mm only installation on DIN rail (60715 TH35)
INSTALLATION RULES.
Installation should be carried out by qualified personnel in complian-
ce with the current regulations regarding the installation of electrical
equipment in the country where the products are installed.
Ensure clearance around the appliance so there is sufficient ventilation.
There must be no dripping or splashes of water on the appliance.
WARNING: To prevent injury, the appliance must be secured to the wall
as described in the installation instructions.
Above the power supply there must be a bipolar circuit breaker that is
easily accessible with a contact gap of at least 3 mm.
CONFORMITY TO STANDARDS.
LV directive.
EMC directive.
Standards EN 60065, EN 61000-6-3, EN 50130-4, EN 50491.
For MARINE use, this device has been submitted to the following tests:
IEC 60068-2-52 - Test Kb: Salt mist, cyclic (sodium, chloride solution),
IEC 60068-2-6 - Test Fc: Vibration (sinusoidal)
This device complies with part 15 of the Rules (with the limits for FCC
a Class B digital device). Operation is subject to the following two con
-
ditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference
that may cause undesidered operation.
FRONT VIEW AND CONNECTIONS.
Overload
Output overvoltage
Mains voltage
Power unit with output 29 V d.c. 1280 mA, power supply 120-230 V~ 50-60 Hz, with decoupling coil, installation on DIN rail (60715
TH35), occupies 8 modules of 17.5 mm. For nautical scope.
120-230 V~
29 V AUX 29 V BUS
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging,
this means the product must not be included with other general waste
at the end of its working life. The user must take the worn product to a
sorted waste center, or return it to the retailer when purchasing a new
one. Products for disposal can be consigned free of charge (without any
new purchase obligation) to retailers with a sales area of at least 400 m
2
,
if they measure less than 25 cm. An efficient sorted waste collection for
the environmentally friendly disposal of the used device, or its subsequent
recycling, helps avoid the potential negative effects on the environment
and people’s health, and encourages the re-use and/or recycling of the
construction materials.

Produkspesifikasjoner

Merke: Vimar
Kategori: batteribank
Modell: 01989

Trenger du hjelp?

Hvis du trenger hjelp med Vimar 01989 still et spørsmål nedenfor, og andre brukere vil svare deg