Vimar 02913 Bruksanvisning
Les nedenfor 📖 manual på norsk for Vimar 02913 (4 sider) i kategorien Termostat. Denne guiden var nyttig for 27 personer og ble vurdert med 4.0 stjerner i gjennomsnitt av 14 brukere
                        Side 1/4
                    
                    
                    
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
02913  03  2206
02913 - LTE thermostat
SMART CLIMA
Electronic LTE thermostat for local control and advanced remote temperature management 
via View  App, heating  and air  conditioning in  ON/OFF and  PID mode,   class  I temperature 
control device (contribution 1%) in ON/OFF mode, class IV (contribution 2%) in PID mode, 
configuration  via  View  App  on  standard  Bluetooth  technology,  1  additional  output  and  1 
digital input, 1  relay output 5(2)  A 240 V~,  power supply 100-240  V~ 50/60 Hz,  white LED 
backlighting, surface mounting, white.
Download the View 
 App from the stores onto the tablet/smartphone you will be 
using for configuration.
You will also need:     
Amazon Alexa, Google Assistant voice assistants for possible voice operation 
CONFIGURATION IN 
1. Create your Administrator or Installer account on MyVimar (on-line).
2. Wire the thermostat.
3. Start the View App and log in with the credentials you just created.
4. To associate the thermostat:
• In the event of  new systems, select “Create smart  system” and give it a  name. Select the 
smart  system  you  just  created    “Customise”    “Smart  devices”    “Add  a  device”     
“VIMAR Smart Thermostat”   “Start”
•  In the case of an existing system, select the smart system   “Customise”   “Smart devices”  
   “Add a device”   “VIMAR Smart Thermostat”   “Start”
•  Press  button B for 5 s; activate the Bluetooth connection on your tablet/smartphone and 
approach the thermostat
•  Select “Proceed” and enter the APN of your phone operator following the instructions pro-
vided by the wizard
Main APN
TIM
ibox.tim.it
Vodafone
web.omnitel.it
Wind3
internet.it
Iliad
iliad
•  Name the thermostat and the actuator of the auxiliary output and then set the time zone
• Go to the “Smart Devices” section and set the thermostat parameters  
For details  please refer  to the manual entitled “Programming  thermostats 02912-02913” 
available for download from www.vimar.com
OPERATION WITHOUT CONFIGURATION VIA APP.  
If  configuration  is  not  done  via  the  View  App,  the  thermostat  is  designed  to  accommodate 
operation in manual mode.
RESETTING THE THERMOSTAT
The reset restores the factory settings. Within the first 5 minutes within which it is powered, press 
button B for 30 s.
 INSTALLATION RULES.
• Installation and configuration must be carried out by qualified persons in compliance with the 
current regulations regarding the installation of electrical  equipment in the country where the 
products are installed.
• The C-NO contact of the relay must be protected against overloads by installing a device, fuse 
or automatic 1-way switch, with a rated current not exceeding 10 A.
• Do not connect a SELV circuit to the NO-C, IN-N and L-1 (auxiliary output) terminals as there 
is no double insulation compared to the L-N terminals.
• The device must be installed at a height of 1.5 m above floor level, in a suitable position for the 
correct detection of the room temperature, avoiding installation in recesses, behind doors and 
curtains, areas affected by heat sources or subject to the flow of forced heating/cooling venti-
lation sources or affected by atmospheric factors. Avoid in particular installation on perimeter 
walls or in association with devices which generate heat (e.g. dimmers or lamps).
IMPORTANT WARNINGS
•  The LTE connection varies depending on the phone operator; check in advance the one in 
your area which guarantees best coverage and purchase the corresponding SIM card.
•  We  recommend  you  use  a  SIM  card  with  a data  contract  with  traffic  of  at  least  50  MB/
month.
•  Before inserting the SIM card in the thermostat, disable the PIN code prompt.
To do this, insert the SIM card in your smartphone and follow the instructions provided to 
disable the PIN.
CHARACTERISTICS.
•  Rated supply voltage: 100-240 V~, 50/60 Hz.
•  Consumption at 100 V~: 
-  brightness L1 (low) and relay OFF 0.3 W
-  brightness L3 (high) and relay ON 0.85 W
•  Consumption at 240 V~: 
-  brightness L1 (low) and relay OFF 0.5 W
-  brightness L3 (high) and relay ON 1 W
•  Bluetooth technology:
-  RF transmission power: < 100 mW (20 dBm)
-  Frequency range: 2400-2483.5 MHz
•  Transmission bands:
-  B1 (2100MHz)
-  B3 (1800MHz)
-  B7 (2600MHz)
-  B8 (900MHz)
-  B20 (800MHz) 
•  Terminals:
- 2 (L and N) for line and neutral
- 2 for digital input 120 - 240 V~ for alarm signalling (for instance boiler shutdown)
Maximum length of the 30 m contact connection cable
- 2 (NO-C) for relay output with voltage-free contact: 5(2) A 240 V~   
- 2 for output 100 mA 120 - 230 V~ to control an auxiliary relay (for instance to switch a boiler 
or a light on/off)   
•  2 front buttons with rocking action for control and settings.
•  1 button (positioned at the bottom) for configuration and reset.
•  Side LEDs:
- 2 on the left for signalling Cloud connection and LTE network connection
- 3 on the right for signalling ON/OFF, relay state and auxiliary output state 
•  White LED display for displaying temperature, set point and configuration state signalling.
• Current settable setpoint: 4 °C ÷ 40 °C.
• Temp. measurement precision (integrated probe): 0.5°C between +15°C and  30°C, 0.8°C at 
the extremes
•  For use for Heating/Air Conditioning (winter/summer).
•  Operating modes: Automatic, Manual, Reduction, Absence, Protection, Off, Timed Manual.
•  Temperature control algorithms: configurable PID or ON/OFF.
•  Operating temperature: T40 (0 °C   +40 °C) (indoor use).÷
•  Protection degree: IP20. 
• ErP  classification  (EU  Reg.  811/2013):  -  ON/OFF:  class  I,  contribution  1%.  -  PID:  class  IV, 
contribution 2%.
• Device in class II
•  Number of manual cycles: 3,000
•  Number of automatic cycles: 100,000
•  Type of contact opening: micro-disconnection
•  Type of action: 1.C
•  Tracking index: PTI175
•  Degree of pollution: 2 
•  Rated pulse voltage: 4000 V
•  Software class: A
•  Reading resolution: 0.1 °C 
•  Settings resolution: 0.1 °C from App and ± 0.5 °C from device  
•  Update of temperature displayed: every 10 s 
•  Room temperature display: 0 °C +40 °C
•  Hysteresis adjustable via App: from 0.1 °C to 1 °C 
•  Hourly temperature setting (via App)
•  Room temperature during transportation: -25 °C +60 °C
•  Clock error: ≤ 1 s per day
•  Configuration via View App using Bluetooth technology
•  Controllable via View App, Amazon Alexa and Google Assistant voice assistants.
•  Dimensions: 106 x 118 x 23.5 mm.
OPERATION.
Using the View App, making use of the 
Internet connection
 the following can be set:
•  Time schedules (times and temperature levels T1, T2 and T3)
•  Setpoint  for  all  operating  modes  (Manual,  Reduction,  Absence,  Protection).  The  operating 
mode can be changed from the View App after one ON/OFF cycle
•  Manual operation time: between 1 min and 23 hours (with 1-min steps); default = 60 min
•  Lighting in standby: high, medium, low, off with default = medium
•  Temperature calibration for heating: between -5°C and +5°C with default = 0°C
•  Temperature calibration for air conditioning: between -5°C and +5°C with default = 0°C
•  Relay output status: normally open, normally closed; default = normally open
•  Auxiliary output state: ON/OFF, timed. 
•  Control type: On/Off, PID; default = On/Off
•  Hysteresis for On/Off control: between 0.1°C and 1°C; default = 0.2°C
•  Proportional band for PID control: between 0.5°C and 5°C; default = 3°C
•  Integrative time for PID control: between 5 min and 120 min; default = 20 min
•  Derivative time for PID control: between 0 and 255 s, disabled; default = 0
•  Cycle time for PID control: between 10 min and 30 min; default = 10 min
In  the  event  of  a  power  outage,  once  the  power  is  restored,  the  thermostat  restarts  with  the 
operating mode prior to the outage.  If the mode set was “Automatic” the thermostat will restart 
in “Manual” mode and the first time it reconnects to the Cloud, it will synchronise the time/date 
again and then switch to “Automatic” mode.
Produkspesifikasjoner
| Merke: | Vimar | 
| Kategori: | Termostat | 
| Modell: | 02913 | 
Trenger du hjelp?
Hvis du trenger hjelp med Vimar 02913 still et spørsmål nedenfor, og andre brukere vil svare deg
Termostat Vimar Manualer
                        
                         24 August 2025
                        
                    
                                                            
                        
                         24 August 2025
                        
                    
                                                            
                        
                         24 August 2025
                        
                    
                                                            
                        
                         24 August 2025
                        
                    
                                                            
                        
                         23 August 2025
                        
                    
                                                            
                        
                         23 August 2025
                        
                    
                                                            
                        
                         23 August 2025
                        
                    
                                                            
                        
                         23 August 2025
                        
                    
                                                            
                        
                         23 August 2025
                        
                    
                                                            
                        
                         23 August 2025
                        
                    
                                                            Termostat Manualer
- GENERAL Life
- HomePilot
- Fibaro
- Oreg
- Easy Timer
- Intertechno
- Bticino
- OJ ELECTRONICS
- Siemens
- VDH
- Plugwise
- Corberó
- Elgato
- Perel
Nyeste Termostat Manualer
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         9 Oktober 2025
                        
                    
                                                            
                        
                         8 Oktober 2025
                        
                    
                                                            
                        
                         6 Oktober 2025
                        
                    
                                                            
                        
                         6 Oktober 2025
                        
                    
                                                            
                        
                         6 Oktober 2025
                        
                    
                                                            
                        
                         24 September 2025
                        
                    
                                                            
                        
                         24 September 2025
                        
                    
                                                            
                        
                         24 September 2025