Xiaomi iHealth Bruksanvisning

Les nedenfor 📖 manual på norsk for Xiaomi iHealth (6 sider) i kategorien Ikke kategorisert. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere

Side 1/6
iHealth thermometer
Users manual
Manufacturer info
Components of the device
Manufacturer: Dongguan Yimai Industrial;
Address: Dongguan city, Changan Town, Jinsha Hexi Industrial Zone, 212 Road;
Contact phone + 86-769-89272488;
Index: 523853;
License number for the production of medical equipment: a license to produce food and
medicine in Guangdong Province 20112017;
Product Registration Number: Guangdong Province No. 2200464 from 2014;
Registered product standards: YZB / Guangdong 0100-2014.
Overview
Thank you for choosing our products.
This device is a high-tech infrared thermometer
for measuring body temperature by placing it
to the forehead, after which you instantly get
information about the health status of you or
your loved ones.
Title: Infrared thermometer;
Model: FDIR-V14.
The external body of the thermometer is made of plastic. The device is equipped with an
infrared temperature sensor, MCU, electro-acoustic components, batteries, LED-screen,
battery components, and backlighting.
Appearance of the device
LED screen
Operation button
Temperature sensor
Proximity sensor
Battery cell
LED screen
Temperature display
area
Battery status
Celsius degrees
Fahrenheit degrees
Dimensions: 137mm х 34mm х 39mm;
Screen: 25.7mm х 19.1mm;
Weight: 90g.
1. Place of measurement: the center of the forehead;
2. Measurement distances: less than 3 cm;
3. Power supply: DC 3V, 2 x 1.5V AAA batteries;
4. Measuring range: 32.0 ° С-42.9 ° С;
5. The accuracy of the measurement: 35.0 ° C-42.0 ° C within ± 0.2 ° C, with another
range within ± 0.3 ° C;
6. Resolution: 0.1 ° С;
7. Accuracy in comparison with the indications of a medical mercury thermometer: within ±
0.3 ° C;
8. Operating environment range: 16.0 ° С-35.0 ° С, <85% RH, 70kPa - 106kPa;
9. Service life: 5 years.
Scope of the device
This device is designed to measure body temperature using a high-tech infrared sensor
by placing it to the forehead. It can be used to measure the temperature of newborns,
children and adults. Now you can forget about the mercury thermometer, especially when
measuring a temperature of newborns and children.
Reminder: for people with di󰀨erent skin color, the temperature measurement distance is
slightly di󰀨erent.
Precautions
I about measuring
1. Do not use a self-medication and do not make a diagnosis yourself, relying only on the
thermometer. If necessary, consult a doctor.
2. The human body temperature does not have a standard value to make the right
conclusions about your health (about the presence or absence of heat), you need to know
your normal temperature.
3. Before measuring the temperature, make sure that there is no make-up, sweat, cream,
etc. on the forehead.
4. Before measuring the temperature, make sure that in the last 30 minutes a person who
needs to measure the temperature did not take a bath, did not exercise, or did not eat. In
this case, the body temperature will be the most accurate.
5. Ensure that there are no wounds or inammation at the temperature measuring point on
the forehead.
6. Do not measure the temperature in the place on the forehead where there are scars,
otherwise the thermometer may be distorted. Scars a󰀨ect the conductivity of temperature
in the body.
7. If there is a signicant di󰀨erence in the room temperature between the thermometer
storage location and the temperature measuring point, leave the thermometer in the new
environment for 30 minutes before proceeding to measure body temperature.
8. Do not measure the temperature immediately after taking medication.
9. With a continuous measurement of temperature, a slight error is possible, this is normal.
Since, as a result of continuous measurement, the temperature of a person’s body has
already been transferred to a thermometer, subsequent indicators may be inaccurate. We
recommend that you measure the temperature no more than three times in a single period
of time.
10. When measuring temperature, try not to be a󰀨ected by air conditioning, sun and other
heating appliances, otherwise there will be a measurement error.
11. Do not measure the temperature in a room with strong electromagnetic interference
(with the microwave oven turned on, induction cooker, in case of talking on the phone at
the moment, etc.), otherwise there will be a measurement error or an error.
12. This product is a personal thing and requires special cleaning and disinfection to avoid
the spread of infection.
13. If the thermometer sensor is dirty, lightly wipe it with cotton swabs soaked in 75%
alcohol solution, then leave the device for 15 minutes before its next use.
II about thermometer
1. This device is designed to perform accurate measurements. After each use of the
thermometer, put it in a packing box for safe storage. Avoid getting liquid, do not allow dust
or other small particles to settle on the device, otherwise this can have a negative e󰀨ect on
the e󰀩ciency of temperature measurement.
2. Avoid dropping and stressing the thermometer on other objects, do not disassemble it.
3. Avoid direct contact of the ngers with the sensor, otherwise the IR sensor may be
damaged or contaminated, which will lead to errors in measuring the temperature.
4. Keep the device out of reach of children to avoid injury or unforeseen situations.
5. Do not drop the device and batteries into a re to prevent an explosion.
6. If the thermometer is not used for more than 1 month, remove the batteries from the
device.
Contraindications
No contraindications.
Using the device
1. Setting the device
Insert two batteries into the special battery compartment, at this time the thermometer
self-test starts, wait for the device to switch to the temperature measurement mode (if the
battery level is low, replace the batteries).
2. Measuring
- direct the thermometer to the center of the forehead and keep
it at a distance of less than 3 cm (at the distance of the index
nger), do not allow direct contact;
- lightly press the button to start the measurement;
- after a successful temperature measurement, the thermometer vibrates
and a number appears on the screen; In the case of a measurement
error, the image «----° C» appears on the screen.
Causes, that may lead to measurement error:
A. The measurement distance is greater than 3 cm;
B. The ambient temperature does not meet the requirements or the temperature di󰀨erence
is too great;
C. The temperature is outside the permissible range.
3. Switching o󰀨 the device
If you no longer need to measure the temperature, wait 8 seconds for the thermometer to
turn o󰀨 automatically.
4. Switching units of measure.
1) In the o󰀨 state, press and hold the measurement button for 8 seconds to enter the unit
selection mode (° C and ° F simultaneously blink).
2) In this mode, after pressing the measurement button on the device screen, Celsius and
Fahrenheit degrees will automatically switch.
3) After selecting the unit of measure, press and hold the measurement button for 8
seconds to conrm your selection and exit the unit switching mode.
Reminder: if you did not press and hold the button for 8 seconds before conrming your
selection, your settings will not be saved and the unit of body temperature measurement
will be the same.
5. Installation and changing a batteries
Each time the thermometer is turned on, it automatically detects the battery level. If you
measure the temperature, then along with the measurement results, an image, indicating
a low level of charge, appears on the screen of the device; if the charge level is so low that
even a temperature measurement can not be performed, a low charge image will appear
on the thermometer screen, and after 8 seconds the device will automatically turn o󰀨. For
further use of the thermometer, it is necessary to replace the batteries.
6. Changing a batteries
1) While holding the battery compartment cover with your ngers, slide it down to fully
open the battery compartment.
2) Remove the old batteries and install new ones.
3) In accordance with the marking indicating the polarity of the batteries, install new ones
according to this markup (plus plus, and minus to minus).
4) Close the battery compartment panel.
- dispose of old batteries in accordance with the requirements of legislative and regulatory
acts.
- Do not dispose of batteries in debris.
- remove the batteries if the device is not used for a long time.
- Do not dispose of batteries in a re.
Information on body temperature
Normal body temperature of a person has certain limits, while the normal temperature of
di󰀨erent people may vary slightly or vary at di󰀨erent times of the day.
Self-treatment and self-diagnosis based on thermometer indicators are dangerous, please,
if necessary, consult a doctor.
The following table contains information on the temperature characteristic of most people
(iHealth thermometer indicators correspond to the temperature in the armpit):
Problem Problem causes Solution
Batteries are exhausted
Batteries not installed
correctly
Bad battery contact
Replace the batteries
Install them correctly
Install the batteries correctly
Charge is too low Replace the batteries
The distance for measuring
the temperature is too high.
The temperature reading is
out of range.
In accordance with the
instruction, repeat the
temperature measurement
The screen shows all the
symbols and indicators, but
they ash continuously.
Contact the service
after-sales service
Charge is too low Replace the batteries
Troubleshooting