COLBOR CL100 Bruksanvisning
Les nedenfor 📖 manual på norsk for COLBOR CL100 (2 sider) i kategorien Lettelse. Denne guiden var nyttig for 32 personer og ble vurdert med 4.4 stjerner i gjennomsnitt av 16.5 brukere
                        Side 1/2
                    
                    
                    
SET RATE EFF CCT
POWER
CL100
Video Light
User Manual
Thank you for choosing COLBOR product. Please read this manual 
carefully before use and follow all instructions mentioned herein.
Caring For Your COLBOR Product
Keep corrosive chemicals, liquids and heat source away from the product to 
prevent mechanics damage.
The product is not waterproof.
Do not leave the product unattended while in use. Keep out of reach of 
children.
Must remove the COB protective cover before use.
Do not handle with wet hands. Do not touch hot COB surface.
Please do not block the ventilation and do not look at the light directly when 
it is on.
Do not attempt to disassemble or modify the product. Doing so voids 
warranty. 
Please have the product checked or repaired by authorized technicians if any 
malfunctions happened.
Disconnect from the power supply when it is not in use.
Malfunction may be caused by dropping, impact of external force.
Failure to follow all the instructions may result in mechanics damage.
Warranty does not apply to human errors.
Product Instructions
① Bowens Mount Release Latch
② LED Display Screen
③ Settings Button
④ EFF Rate Option Button
⑤ Adjustment Dial
⑥ EFF Mode Button
⑦ CCT Mode / Power Button
⑧ Power Input
⑨ Umbrella Lock
⑩ Umbrella Input
⑪ Light Base Lock
⑫ Light Base
⑬ Direction Adjusting Handle
Operation Instructions
After selecting wireless connection in Settings menu, the 
icon will be displayed dynamically.
The icon is always on to indicate successful pairing with 
mobile APP.
The icon disappears to indicate mobile APP pairing 
failure, or the product is unpaired.
Smart Mode. The product will adjust the fan speed 
according to the internal detected temperature to ensure 
that it is in optimal working condition.
Status Icon Description
1. Connect the power cord with the power adapter, plug the connector of 
adapter into the xture’s Power Input
2. Plug it into an electricity supply
3. Long press the Power Button to turn on the light. Default Mode: CCT
4. Long press the Power Button to turn o the light.
① APP Connection Status Icon
② Fan Status Icon
Quiet Mode. The fan keeps running at low speed for 
minimum noise, and overheating protection will be 
activated if the product temperature is higher than the 
alarm value.
None grouping status. The product defaults to the factory 
status, and will not be aected by other groups.
If the icon is always on, it means that Repeater function 
is turned on, and if the icon disappears, it means the 
function is turned o.
If the icon ashes, it means that the internal temperature 
of the product is too high, and cooling measures need 
to be taken. If the icon disappears, it means that the 
operation is normal.
③ Group Status Icon
④ Repeater Status Icon
⑤ Product Overheated Alarm Icon
A stands for Group A. There are six groups (A~F). T 
stands for Tx.
A stands for Group A. There are six groups (A~F). R 
stands for Rx.
A stands for Group A. There are six groups (A~F). TR 
stands for TxRx.
Brightness (0%-100%)
Color Temperature (2700K-6500K)
1. Short press Adjustment Dial to switch between brightness and color 
temperature control.
CCT Mode (Short press CCT Mode Button to enter)
Brightness / Color Temperature Control: 
Interface Introduction
2. Roll the Dial clockwise to increase value, and anticlockwise to decrease 
value.
Rolling the Dial will enlarge the current setting parameter value, and it will 
automatically return to the main screen after 1.5 seconds of no operation
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: LOCK
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: LOCK
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: Lv.1 - Lv.5
DIM: 0%-100%
CCT: 2700K-6500K
RATE: LOCK
DIM: 0%-100%
CCT: 2700K-6500K
Fire
CCT Chase
Pulsing
TV
Explosion
Faulty Bulb
Welding
Strobe
Lightning
SOS
EFF
Rate
BrightnessSpecial Eect
Color Temperature
EFF Mode (Short press EFF Mode Button to enter)
Special Eect Switch: Short press EFF Mode Button
Interface Introduction
SET RATE EFF CCT
POWER
SET RATE EFF CCT
POWER
Produkspesifikasjoner
| Merke: | COLBOR | 
| Kategori: | Lettelse | 
| Modell: | CL100 | 
Trenger du hjelp?
Hvis du trenger hjelp med COLBOR CL100 still et spørsmål nedenfor, og andre brukere vil svare deg
Lettelse COLBOR Manualer
                        
                         16 Januar 2025
                        
                    
                                                            
                        
                         16 Januar 2025
                        
                    
                                                            
                        
                         16 Januar 2025
                        
                    
                                                            
                        
                         13 Januar 2025
                        
                    
                                                            
                        
                         13 Januar 2025
                        
                    
                                                            
                        
                         18 Desember 2024
                        
                    
                                                            
                        
                         18 Desember 2024
                        
                    
                                                            
                        
                         18 Desember 2024
                        
                    
                                                            
                        
                         18 Desember 2024
                        
                    
                                                            
                        
                         18 Desember 2024
                        
                    
                                                            Lettelse Manualer
- Philips
- LUPO
- Yamazen
- Showtec
- Excello
- Singercon
- Eglo
- Infinity
- ET2
- Brennenstuhl
- Yongnuo
- GlobalTronics
- Canarm
- Neewer
- Martin
Nyeste Lettelse Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         8 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         6 April 2025
                        
                    
                                                            
                        
                         6 April 2025
                        
                    
                                                            
                        
                         6 April 2025
                        
                    
                                                            
                        
                         6 April 2025