Gossen Metrawatt SecuLife HIT MD Bruksanvisning

Gossen Metrawatt Multimeter SecuLife HIT MD

Les nedenfor 📖 manual på norsk for Gossen Metrawatt SecuLife HIT MD (70 sider) i kategorien Multimeter. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere

Side 1/70
SECULIFEHITAM HITMD
METRAHIT X-TRA OUTDOOR TECH PRO BASE
TRMS Digital Multimeter
Operating Instructions
3-349-352-03
13/5.17
2 GMC-I Messtechnik GmbH
Standard Equipment Contact Persons
Standard Equipment
1multimeter
1 measurement cable set
2 batteries
1 abbreviated operating instructions
Detailed operating instructions for download from our website
at www.gossenmetrawatt.com
1 DAkkS calibration certificate
1)
For 15,400 measured values, sampling rate adjustable from 0.1 second to 9 hours
Function SECULIFE
HIT
AM
/HIT
MD
METRAHIT
X-
TRA
/
OUTDOOR
METRAHIT
T
ECH
METRAHIT
P
RO
METRA HIT
B
ASE
M687A/M687B M240A/M240O
M243A M242A M241A
V AC / Hz TRMS
(Ri 9 M)
&Filter
&Filter
& Filter
&Filter
V AC TRMS
(Ri = 1 M)
&Filter
&Filter
& Filter
&Filter
V AC+DC TRMS
(Ri 9 M)

V DC ( 9 M) 
... 1 MHz 5 V AC ——
Duty cycle as % ——
Hz (V AC) ... 100 kHz ... 100 kHz ... 100 kHz ... 100 kHz ... 100 kHz
Bandwidth V AC
15 Hz ... 20 kHz 15 Hz ... 20 kHz 15 Hz ... 10 kHz 15 Hz ... 10 kHz
15 Hz ... 1 kHz
A AC / Hz TRMS
100 A
1/10/100 mA
1 A / 10 (16)
A
100 A
1/10/100 mA
1 A / 10 (16)
A
10/100 mA
1 A / 10 (16)
A
1 A / 10 (16)
A
A AC+DC TRMS
A DC
Fuse 10 A/1000 V 10 A/1000 V 10 A/1000 V 10 A/1000 V
Transformation
factor
——
A AC / Hz
TRMS
——
mV/A
mA/A
mV/A
Ri = 1 M
A AC+DC TRM
S
——
mV/A
mA/A
mV/A
Ri = 1 M
1kHz
1kHz
1kHz
1kHz
1kHz
1kHz
1kHz
1kHz
A DC
——
mV/A
mA/A
mV/A
Ri = 1 M
Hz (A AC) ... 30 kHz ... 30 kHz ... 30 kHz ... 30 kHz ... 30 kHz
Resistance 
Continuity 
Diode ... 5,1 V 
Temperature TC (K) 
Temperature RTD
——
Capacitance ——
MIN/MAX/data hold 
4 MBit memory
1)
——
IR Interface ——
Power pack
adapter socket
——
Protection
IP65
X-TRA: IP52
OUTDOOR: IP65
IP52 IP52 IP52
Antimicrobial
properties
/———
Measuring category 600 V CAT II I
300 V CAT IV
1000 V CAT III
600 V CAT IV
1000 V CAT III
600 V CAT IV
1000 V CAT III
600 V CAT IV
1000 V CAT III
600 V CAT IV
Rubber holster ——
Measurement cable set
KS17-2AMB/
KS17-2
KS17-2 KS17-2 KS17-2 KS17-2
DAkkS calibr. certificate

Hygiene Expertise — / ———
Function SECULIFE
HIT
AM
/HIT
MD
METRAHIT
X-
TRA
/
OUTDOOR
METRAHIT
T
ECH
METRAHIT
P
RO
METRA HIT
B
ASE
M687A/M687B M240A/M240O
M243A M242A M241A
GMC-I Messtechnik GmbH 3
Contact Persons
Accessories (sensors, plug inserts, adapters, consumable materials)
The accessories available for your instrument are checked for
compliance with currently valid safety regulations at regular
intervals, and are expanded as required for new applications.
Currently up-to-date accessories which are suitable for your
measuring instrument are listed at the following web address
along with photo, order number, description and, depending
upon the scope of the respective accessory, data sheet and
operating instructions:
www.gossenmetrawatt.com
See also chapter 10 on page 66.
Product Support
Technical Queries
(use, operation, software registration)
If required please contact:
GMC-I Messtechnik GmbH
Product Support Hotline
Phone: +49 911 8602-0
Fax: +49 911 8602-709
e-mail support@gossenmetrawatt.com
Software Enabling for METRAwin 10
GMC-I Messtechnik GmbH
Front Office
Phone: +49 911 8602-111
Fax: +49 911 8602-777
e-mail: info@gossenmetrawatt.com

Produkspesifikasjoner

Merke: Gossen Metrawatt
Kategori: Multimeter
Modell: SecuLife HIT MD

Trenger du hjelp?

Hvis du trenger hjelp med Gossen Metrawatt SecuLife HIT MD still et spørsmål nedenfor, og andre brukere vil svare deg