telt 100
40.02.0001.1
Made in the EU
2
3
1
4
5
6
N
L
L
N
16
18
N
L
L
N
16
18
Leopoldstr. 1
78112 St. Georgen / Germany
www.graesslin.de
Emergency light tester
Characteristics
Description
Connection
EN
Technical parameters
• Time relay for automatic testing of emergency lighting.
• Panel button for starting the test.
• Comfortable and well-arranged time delay (t) setting by rotary switch.
• Adjustable time delay 10 m – 30 m – 60 m – 90 m – 120 m – 180 m is divided into
six ranges.
• ZERO CROSS feature: closes and opens the output contact when the voltage
crosses zero.
• Multifunction red LED ashes or shines depending on the operating states.
1. Supply voltage terminals (N-L)
2. Supply voltage indication
3. Indication of operating states
4. Time delay (t) setting
5. Test button
6. Output contact (16-18)
Direct emergency lighting
connection (for I<16A)
Emergency lighting connection
through contactor (for I>16A)
Power supply
Supply terminals:
Supply voltage:
Consumption (max.):
Supply voltage tolerance:
Time circuit
Number of functions:
Time delay (t):
Time setting:
Time deviation:
Repeat accuracy:
Temperature coe cient:
Output
Contact type:
Current rating:
Breaking capacity:
Inrush current:
Switching voltage:
Power dissipation (max.):
Mechanical life:
Electrical life (AC1):
Other information
Operating temperature:
Storage temperature:
Operating position:
Mounting:
Protection degree:
Overvoltage category:
Pollution degree:
Cross-wire section – solid/
stranded with ferrule (mm
2
):
Dimensions:
Weight:
Standards:
L-N
AC 230 V (50-60 Hz)
3.9 VA/1.9 W
–15 %; +10 %
1
10 m – 30 m – 60 m – 90 m – 120 m – 180 m
rotary switch
5 % – mechanical setting
0.2 % – set value stability
0.01 %/°C, at = 20 °C (0.01%/°F, at = 68 °F)
1× changeover (AgSnO
2
); changes the potential "L"
16 A/AC1; 1 HP|240 Vac, 1/2HP|120 Vac; PD. B300
4000 VA/AC1, 384 W/DC1
80 A/20 ms (NO contact)
250 V AC/24 V DC
1.2 W
10.000.000 ops.
20.000 ops.
–20 .. +40 °C
–30 .. +70 °C
any
DIN rail EN 60715
IP40 front panel / IP20 terminals
III.
2
max. 1× 2.5, 2× 1.5/
max. 1× 2.5 (AWG 14)
90 × 17.6 × 64 mm
53 g
EN 61812-1
Produkspesifikasjoner
| Merke: | Grasslin |
| Kategori: | Ikke kategorisert |
| Modell: | telt 100 |
Trenger du hjelp?
Hvis du trenger hjelp med Grasslin telt 100 still et spørsmål nedenfor, og andre brukere vil svare deg
Ikke kategorisert Grasslin Manualer
3 Februar 2025
4 Januar 2025
Ikke kategorisert Manualer
- OptiTrack
- Ditek
- Dyson
- Carrier
- Supermicro
- GBC
- REVITIVE
- Prompter People
- Primacoustic
- Zhiyun
- Sure Petcare
- Bobrick
- Nubert
- Moultrie
- Nilox
Nyeste Ikke kategorisert Manualer
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025