Side 1/84
61-757 600-Amp
61-747 400-Amp
TightSight™ Clamp Meter
Operation and Safety Manual
IDEAL
®
Test and Measurement
Instrucciones en español adentro / Instrucions en français à l’intérieur
Table of Contents
2
Introduction ......................................................................3
Contacting IDEAL INDUSTRIES, INC ..........................................3
Safety Information ...............................................................4
Warnings ................................................................................................... 4-5
Cautions ........................................................................................................ 5
Symbols .................................................................................................... 6-7
Operation ..................................................................8-23
Identification and description of operating controls and functions ............ 8-9
Operating Features ............................................................................... 10-11
Using Test Leads ........................................................................................12
Meter Operation ................................................................................... 13-17
Non-Contact Voltage Testing...........................................................13
Measuring Current .......................................................................... 14
Measuring Voltage ..........................................................................14
Measuring Continuity .....................................................................15
Measuring Resistance ..................................................................... 15
Measuring Capacitance ...................................................................16
Measuring Diodes ...........................................................................16
Measuring Frequency .....................................................................17
Measuring Temperature ..................................................................17
Functions Operation Table .................................................................... 18-19
Functions Indication Table .................................................................... 20-21
Electrical Specifications ........................................................................ 22-23
Environmental Specifications ................................................ 24
Mechanical Specifications ................................................... 24
EMC / EMI ....................................................................... 24
FCC ............................................................................... 25
Safety ............................................................................ 25
Maintenance and Service ................................................ 26-27
Introduction
The IDEAL
®
61-757 and 61-747 TightSightClamp Meters are auto ranging
true root mean square (TRMS) digital clamp meters that measure AC and DC
current (amps) via the clamp head, measure voltage, frequency, resistance,
continuity, capacitance, diode via test-leads and measure temperature via a
K-Type thermocouple, and detects the presence of voltage between 40V to 600V
via a non-contact sensor in the right tip of the clamp.
Contacting IDEAL INDUSTRIES, INC.
To contact IDEAL INDUSTRIES, INC., call one of the following telephone numbers:
IDEAL Industries USA Customer Service
• Phone Number: 800-435-0705
• Email: contactus@idealindustries.com
IDEAL Industries Canada Customer Service
• Phone Number: 905-683-3400
• Email: ideal_Canada@idealindustries.com
IDEAL Industries EMEA
• Phone Number: +44 (0)1925 444 446
• Email: eur.sales@idealindustries.com
IDEAL Industries Australia
• Phone Number: +61 3 9562 0175
• Email: InfoAUS@idealindustries.com
Or visit the IDEAL Electrical Website at www.idealind.com
To register your product, find manuals, watch videos, simply scan this QR code.
3
Arc Flash and Shock Hazard, Proper PPE Required. Follow all safety procedures,
wear proper PPE in accordance to NFPA 70E. Read and fully understand the
instruction manual prior to using this product. Failure to comply can result in
serious injury or death.
Introduction ......................................................................3
Contacting IDEAL INDUSTRIES, INC ..........................................3
Safety Information ...............................................................4
Warnings ................................................................................................... 4-5
Cautions ........................................................................................................ 5
Symbols .................................................................................................... 6-7
Operation ..................................................................8-23
Identification and description of operating controls and functions ............ 8-9
Operating Features ............................................................................... 10-11
Using Test Leads ........................................................................................12
Meter Operation ................................................................................... 13-17
Non-Contact Voltage Testing...........................................................13
Measuring Current .......................................................................... 14
Measuring Voltage ..........................................................................14
Measuring Continuity .....................................................................15
Measuring Resistance ..................................................................... 15
Measuring Capacitance ...................................................................16
Measuring Diodes ...........................................................................16
Measuring Frequency .....................................................................17
Measuring Temperature ..................................................................17
Functions Operation Table .................................................................... 18-19
Functions Indication Table .................................................................... 20-21
Electrical Specifications ........................................................................ 22-23
Environmental Specifications ................................................ 24
Mechanical Specifications ................................................... 24
EMC / EMI ....................................................................... 24
FCC ............................................................................... 25
Safety ............................................................................ 25
Maintenance and Service ................................................ 26-27

Produkspesifikasjoner

Merke: Ideal
Kategori: måleinstrument
Modell: 61-757

Trenger du hjelp?

Hvis du trenger hjelp med Ideal 61-757 still et spørsmål nedenfor, og andre brukere vil svare deg




måleinstrument Ideal Manualer

Ideal

Ideal 61-647 Bruksanvisning

15 September 2025
Ideal

Ideal 61-757 Bruksanvisning

14 September 2025
Ideal

Ideal 61-415 Bruksanvisning

14 September 2025

måleinstrument Manualer

Nyeste måleinstrument Manualer