Little Giant 9SC-CIM Bruksanvisning

Les nedenfor 📖 manual på norsk for Little Giant 9SC-CIM (32 sider) i kategorien Vannpumpe. Denne guiden var nyttig for 5 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere

Side 1/32
9SC & 10SC SERIES
OWNER'S MANUAL
English
EN
This submersible sewage pump is for use in basins or
lift stations and is suitable for pumping effluent gray
water or wastewater with up to 2" (51 mm) spherical
semi-solids. Do not use the pump in applications
where any other debris (gravel, sand, floating debris,
etc.), abrasives, or corrosives are present.
The pump motor is equipped with an automatic reset-
ting thermal protector and may restart unexpectedly.
Protector tripping is an indication of motor overload-
ing/overheating, which can be caused by application
issues such as an obstructed pump impeller, switch
stuck in the ON position, pump running dry, pump air-
locked, pump short cycling, excessively high or low
voltage supply, or possibly a pump, motor, bearings, or seal that have reached the end of their useful life.
This product is covered by a Limited Warranty for a period of 3 years from the date of original purchase by
the consumer. For complete warranty information, refer to www.littlegiant.com
.
Specifications
Model HP Volts Hz
Amps
Watts
Maximum Water
Temperature
FLA Start
9SC 4/10
115 60
8.0
18.5
870
140 °F
(60 °C)
10SC (2” Discharge)
1/2
11.0 1225
230 50/60 5.5/5.5 13/13
991/1214
10SC (3” Discharge)
1004/1228
115 60 11.5 18.5 1270
Model
Gallons (Liters) per Minute, at Height Shut Off
5 ft (1.5 m) 10 ft (3 m) 15 ft (4.5 m) 20 ft (6.1 m) Feet (Meters) PSI (Bar)
9SC 100 (379) 80 (303) 60 (227) - 20 (6.1) 8.7 (0.6)
10SC (2” Discharge) 120 (454) 100 (379) 80 (303) 42 (159) 25 (7.6) 10.9 (0.7)
10SC (3” Discharge) 130 (492) 110 (416) 85 (322) 50 (189) 25 (7.6) 10.8 (0.7)
Model Switch Type ON Level OFF Level
9SC-CIA-SFS Integral Snap-Action Float 10 - 13” (25 - 33 cm) 5 - 8” (13 - 20 cm)
9SC-CIA-RF
Piggyback Mechanical Float 16 - 19” (41 - 48 cm) 9 - 11” (23 - 28 cm)
10SC-CIA-RF
10SC-CIA-SFS Integral Snap-Action Float 11 - 14” (28 - 36 cm) 6 - 9” (15 - 23 cm)
SAFETY INSTRUCTIONS
Specifications
2
SAFETY INSTRUCTIONS
This equipment should be installed and serviced by technically qualified personnel who are familiar with
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with
national and local electrical and plumbing codes and within Little Giant recommendations may result in
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product’s application, limitations, and potential hazards. Read and follow instructions carefully to
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following
hazards:
Risk of death, personal injury, or property damage due to explosion,
fire, or electric shock.
Do not use to pump flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.
Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.
Do not handle a pump or pump motor with wet hands or when standing on a wet or damp surface, or in water.
When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electri-
cally disconnected.
If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of
power.
If the disconnect panel is not accessible, contact the electric company to stop service.
High voltages capable of causing severe injury or death by electrical
shock are present in this unit.
To reduce risk of electrical shock, disconnect power before working on or around the system. More than one dis-
connect switch may be required to de-energize the equipment before servicing.
This product is supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of elec-
tric shock, be certain that it is connected only to a properly grounded grounding-type receptacle. Do not remove
the third prong from the plug. The third prong is to ground the pump to help prevent possible electric shock haz-
ard. Do not use an extension cord.
Check electrical outlets with a circuit analyzer to ensure power, neutral, and ground wires are properly con-
nected. If not, a qualified, licensed electrician should correct the problem.
Wire pump system for correct voltages.
The flexible jacketed cord assembly mounted to the pump must not be modified in any way, with the exception
of shortening the cord to fit into a control panel. Any splice between the pump and the control panel must be
made within a junction box mounted outside of the basin and comply with the National Electrical Code. Employ a
licensed electrician.
The pump has been evaluated for use with water only. Pump should only be used with liquids compatible with
pump component materials. If the pump is used with liquids incompatible with the pump components, the liquid
can cause failure to the electrical insulation system resulting in electrical shock.
Check local electrical and building codes before installation. The installation must be in accordance with their
regulations as well as the most recent National Electrical Code (NEC).
Do not remove the third prong from the plug, or cut plug from cord. These actions will void the warranty.
SAFETY INSTRUCTIONS
Specifications
3
Risk of bodily injury, electric shock, or equipment damage.
This equipment must not be used by children or persons with reduced physical, sensory or mental abilities, or
lacking in experience and expertise, unless supervised or instructed. Children may not use the equipment, nor
may they play with the unit or in the immediate vicinity.
Equipment can start automatically. Always unplug the pump power cord and disconnect the electrical power
before servicing the pump or switch.
An inoperative or malfunctioning pump could lead to flooding, resulting in personal injury or property damage.
Use with approved liquid level control with correct rating that matches marked motor input in full load amperes
or service factor amperes.
In applications where property damage and/or personal injury might result from an inoperative or leaking pump
due to power outages, discharge line blockage, or any other reason, an automatic back-up system and/or an
alarm should be installed.
Do not run the pump dry. If run dry, the surface temperature of the pump will rise to a high temperature that
could cause skin burns if touched and will cause serious damage to your pump.
Do not oil the motor. The pump’s motor housing is sealed, with a high-grade dielectric oil for heat transfer and
lifetime lubrication. Use of other oils could cause serious electric shock and/or permanent damage to the pump.
Operation of this equipment requires detailed installation and operation instructions provided in this manual.
Read entire manual before starting installation and operation. End User should receive and retain manual for
future use.
Keep safety labels clean and in good condition.
Do not use motor in swimming areas.
Risk of damage to pump or other equipment.
Do not use this pump for pumping sea water, beverages, acids, chemical solutions, or any other liquid that pro-
motes corrosion as this can result in damage to the pump.
Do not run pump dry. For optimal cooling and to prolong the motor life, the liquid level being pumped should nor-
mally be above the top of the pump housing.
This pump is not suitable for pond applications.

Produkspesifikasjoner

Merke: Little Giant
Kategori: Vannpumpe
Modell: 9SC-CIM

Trenger du hjelp?

Hvis du trenger hjelp med Little Giant 9SC-CIM still et spørsmål nedenfor, og andre brukere vil svare deg




Vannpumpe Little Giant Manualer

Vannpumpe Manualer

Nyeste Vannpumpe Manualer