STARTING THE DEVICE:
Press the button 5    on the side of the Turbo to turn the 
device on (Turbo + towel dryer).
•  Indicators 2 and 3: Steady green - Turbo + Towel dryer  
  turned on
•  Filter indicator 1: Off
•  Indicator 3: Steady red - towel dryer running
BLOWER 2 OPERATING LIGHT:
•  Off: Power Off
•  Steady green: Power On
•  Blinking red: Operating
TURBO 1000 WATT 
The Turbo is designed to quickly raise the temperature in your bathroom.
•   Install the timer in the same room as the towel dryer. The  
  timer must be installed about 1.5 metres above the floor,  
  on  an  inside  wall,  away  from  splashing  water,  direct  
  sunlight and direct source of direct thermal disturbance. 
Note:  To ensure proper infrared transmission: 
-   Do not obstruct transmitter and receiver cells
  (bath towels in front of the cell).
-  Avoid using electronic ballast lighting in the same room.
•   Set the dial for the desired time and press the “OK / Boost”  
  button to start the blower.
NOTE: Forced operation of the device can be interrupted at 
any time by pressing the “OK / Boost” button again. When 
restarting the blower in this case, the remaining Boost time 
will be the setting shown on the dial.
Infrared receiver on Turbo
UK
1.  Filter cleaning indicator
2.  Blower operation indicator
3.  Towel dryer operation indicator
4.  Infrared receiver cell
5.  Start/towel dry button    
SPECIFIC CASES
Overheating
If  towels or  any  other obstructions block  the Turbo outlet 
excessively, causing overheating, the device will shut down 
(indicators 2 and 3 blinking red / green). The Turbo operation 
will restart once the  temperature cools, for the  remaining 
preset length of time.
Thermal safety:
If  the  Turbo  resistor  overheats  a  manually  reset  thermal 
safety device mechanically stops blower operation. 
Indicator light status:
•  Filter indicator 1: Blinking red and
•  Blower indicator 2: Steady green
Important:  A dirty filter can  cause overheating.  Clean it if 
necessary. Press button 5 “start/stop” for 5 seconds to stop 
this alarm.
Note: Please clean the filter each time the Clean Filter alarm 
is triggered (“see Cleaning the Filter”).
Caution: if the cause of overheating has not been identified 
the alarm will be triggered again. In this case, please contact 
the installer since this may cause  the Turbo to deteriorate 
over time.
The  infrared  timer  trans-
mitter lets  you send a  start 
command  to  the  Turbo  for 
a  variable  period  of  0  to  2 
hours.
TIMER ON HOT WATER VERSION DEVICES
21 43 5
Produkspesifikasjoner
| Merke: | Radson | 
| Kategori: | Termostat | 
| Modell: | Turbo | 
Trenger du hjelp?
Hvis du trenger hjelp med Radson Turbo still et spørsmål nedenfor, og andre brukere vil svare deg
Termostat Radson Manualer
                        
                         27 Oktober 2024
                        
                    
                                                            
                        
                         27 Oktober 2024
                        
                    
                                                            
                        
                         27 Oktober 2024
                        
                    
                                                            
                        
                         27 Oktober 2024
                        
                    
                                                            
                        
                         27 Oktober 2024
                        
                    
                                                            
                        
                         27 Oktober 2024
                        
                    
                                                            Radson 51052 - SLAVE RF 4 or 6 Zones Thermostaat Bruksanvisning
18 Oktober 2024
                        
                         18 Oktober 2024
                        
                    
                                                            Termostat Manualer
- Bticino
- ACV
- AVM
- Bulex
- Tado
- Sygonix
- Hager
- VDH
- Muller
- Levica
- Econo-Heat
- Netatmo
- Eliwell
- Brink
- GENERAL Life
Nyeste Termostat Manualer
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         19 Oktober 2025
                        
                    
                                                            
                        
                         9 Oktober 2025
                        
                    
                                                            
                        
                         8 Oktober 2025
                        
                    
                                                            
                        
                         6 Oktober 2025
                        
                    
                                                            
                        
                         6 Oktober 2025
                        
                    
                                                            
                        
                         6 Oktober 2025
                        
                    
                                                            
                        
                         24 September 2025
                        
                    
                                                            
                        
                         24 September 2025
                        
                    
                                                            
                        
                         24 September 2025