Sauermann KH 50 Bruksanvisning

Les nedenfor 📖 manual på norsk for Sauermann KH 50 (2 sider) i kategorien måleinstrument. Denne guiden var nyttig for 9 personer og ble vurdert med 4.9 stjerner i gjennomsnitt av 5 brukere

Side 1/2
Conguration and data viewing
software freely downloadable
KT 50 - KH 50
KISTOCK Data logger
or HVAC - Temperature, Humidity
Conguration and data processing
software available as option
16,000 measurement points
2 congurable setpoint alarms
1 line LCD display
Fast data download (1,000 values/second)
IP65 (KT 50) and IP20 (KH 50) housing
DATA SHEET
KT 50 KH 50
Units displayed °C, °F °C, °F, %RH
Resolution 0.1 °C, 0.1 °F 0.1 °C, 0.1 °F, 0.1 %RH
External inputs Micro-USB connector
Internal sensor Temperature Humidity, temperature
Setpoints alarm 2 setpoint alarms on each channel
Frequency of measurement From 1 minute to 24 hours
Operating temperature
(1)
From -40 to +70 °C
-40 to +158 °F
From -20 to +70 °C
-4 to +158 °F
Storage temperature From -20 to +50 °C / -4 to +122 °F
Battery life 500 days
(2)
365 days
(2)
Standards
2014/30/EU EMC; 2014/35/EU Low Voltage;
2011/65/EU RoHS II; 2012/19/EU WEEE;
FCC part 15; UL 61010
General features
Magnetic
mounting
(1)
The screen can be hard to read, and its display speed often slows down at temperatures lower than 0 °C / 32 °F. This has no effect on the accuracy of measurements.
(2)
Non-contractual value. Based on 1 measurement each 15 minutes at 25 °C / 77 °F. A correct operation of the device and the storage conditions must be respected.
°C
°F
Housing
Dimensions 61.3 x 40 x 21.9 mm / 2
13
/
32
’ x 1
9
/
16
’ x
7
/
8
Weight 40 g / 1.42 oz
Display
1 line LCD screen
Screen dimensions: 26.5 x 22.5 mm / 1
3
/
64
‘ x
57
/
64
Control 1 OK key
Material
Compatible with food industry environment
ABS housing. Caps made of Elastomer
Protection rating IP65: KT 50. IP20: KH 50
PC communication 1 micro USB input
Battery power supply 2 x CR2032 (lithium 3 V)
Environmental
conditions of use
Hygrometry: in non-condensing condition
Maximum altitude: 2000 m / 2188 yd
Air and neutral gases
KT 50 TemperatureInternal sensor
Type of sensor NTC
Measuring range From -40 to +70 °C / -40 to +158 °F
Accuracy*
±0.4 °C from -20 to 70 °C ±0.8°C below -20 °C
±0.8 °F from -4 to 158 °F ±1.5 °F below -4 °F
Technical specications
* All accuracies indicated in this document were stated in laboratory conditions and can be guaranteed for
measurements carried out in the same conditions, or carried out with calibration compensation.
** Factory calibration uncertainty: ±0.88 %RH. Temperature dependence: ±0.04 x (T-20) %HR if T<15 °C or T>
25 °C / ±0.04 x [((T°F - 32) x 5/9) -20] %RH (if T<59°F or T>77°F).
KH 50 Hygrometry TemperatureThermo-hygrometer
Type of sensor Capacitive NTC
Measuring range From 0 to 100% RH
From -20 to +70 °C
-4 to 158 °F
Accuracy*
±2.5 %RH (from +15
to +25°C / +59 to
+77 °F from 5 to 95
%RH)**
±0.4 °C from 0 to +50 °C
±0.8 °F from +32 to +122 °F
±0.8 °C below 0 °C or
above +50 °C
±1.5 °F below 32 °F or
above 122 °F
EN 12830
KT 50

Produkspesifikasjoner

Merke: Sauermann
Kategori: måleinstrument
Modell: KH 50

Trenger du hjelp?

Hvis du trenger hjelp med Sauermann KH 50 still et spørsmål nedenfor, og andre brukere vil svare deg