Tripp Lite NGI-S04C2 Bruksanvisning

Les nedenfor 📖 manual på norsk for Tripp Lite NGI-S04C2 (138 sider) i kategorien Ikke kategorisert. Denne guiden var nyttig for 3 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere

Side 1/138
1
2
COPYRIGHT
All rights reserved. No part of this publication may be reproduced, stored in a retrieval
system, or transmitted in any form or by any means, whether electronic, mechanical,
photo copying, recording or otherwise, without the prior written permission of the
publisher.
FCC WARNING
This equipment has been tested and found to comply with the limits for a
class A device, pursuant to part 15 of FCC rules. These limits are designed
to provide reasonable protection against harmful interference in a
commercial installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communication.
Operation of this equipment in a residential area is likely to cause harmful
interference, in which case, the user will be required to correct the
interference at the user’s own expense.
This is a Class A product. In a domestic environment, this product may
cause radio interference in which case the user may be required to take
adequate measures.
Take special care to read and understand all the content in the warning
boxes.
Do not work on the system or connect or disconnect cables during
periods of lightning activity.
Warning
Warning
3
Before working on equipment that is connected to power lines,
remove jewelry (including rings, necklaces, and watches). Metal
objects will heat up when connected to power and ground and can
cause serious burns or weld the metal object to the terminals.
Do not stack the chassis on any other equipment. If the chassis falls, it
can cause severe bodily injury and equipment damage.
An exposed wire lead from a DC-input power source can conduct
harmful levels of electricity. Be sure that no exposed portion of the
DC-input power source wire extends from the terminal block plug.
Ethernet cables must be shielded when used in a central office
environment.
If a redundant power system (RPS) is not connected to the switch,
install an RPS connector cover on the back of the switch.
Read the wall-mounting instructions carefully before beginning
installation. Failure to use the correct hardware or to follow the
correct procedures could result in a hazardous situation to people and
damage to the system.
Before performing any of the following procedures, ensure that power
is removed from the DC circuit.
Warning
Warning
Warning
Warning
Warning
Warning
Warning

Produkspesifikasjoner

Merke: Tripp Lite
Kategori: Ikke kategorisert
Modell: NGI-S04C2
Vekt: 870 g
Bredde: 50 mm
Dybde: 119.9 mm
Høyde: 160 mm
LED-indikatorer: Speed, Power
Sertifisering: FCC, CE, RoHS, REACH
Auto MDI/MDI-X: Ja
DHCP-funksjoner: DHCP snooping
DIN-skinnemontering: Ja
Produktfarge: Sort
Driftstemperatur (T-T): -10 - 60 °C
Oppbevaringstemperaturomåde (Celsius): -40 - 85 °C
Kroppsmateriale: Metall
Relativ luftfuktighet under drift (H-H): 5 - 95
Svitsjtype: Uhåndtert
Antall Basic switching RJ-45 Ethernet-ports: 4
Basic switching RJ-45 Ethernet ports-type: Gigabit Ethernet (10/100/1000)
Størrelse på adressetabell: 8000 oppføringer
Ruting/svitsjekapasitet: 12 Gbit/s
Kan stables: Ja
Strømforsyning medfølger: Ja
Strøm over Ethernet (PoE): Nei
DC inngående spenning: 20 - 60 V
SFP module antall spor: 2
MAC-adresse automatisk læring støttes: Ja