Owner’s Manual
Rackmount Power Distribution Unit (PDU)
Models: PDUH20DV & PDUH20HVL6
Important Safety Instructions 2
Features 2-3
Installation 3-4
Warranty & Warranty Registration 5
Español 6
Français 11
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2014 Tripp Lite. All rights reserved.
14-02-329-933047.indb 1 4/23/2014 3:39:23 PM
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the
installation, operation, and storage of this product. Failure to heed these instructions and
warnings may affect the product warranty.
• ThePDUprovidesconvenientmultipleoutlets,butitDOESNOTprovidesurgeorline
noise protection for connected equipment.
• ThePDUisdesignedforindooruseonlyinacontrolledenvironmentawayfromexcess
moisture,temperatureextremes,conductivecontaminants,dustordirectsunlight.
• DonotconnectthePDUtoanungroundedoutletortoextensioncordsoradaptersthat
eliminate the connection to ground.
• ThepowerrequirementforeachpieceofequipmentconnectedtothePDUmustnot
exceedtheindividualoutlet’sloadrating.
• ThetotalpowerrequirementforequipmentconnectedtothePDUmustnotexceedthe
maximumloadratingforthePDU.
• DonotdrillintoorattempttoopenanypartofthePDUhousing.Therearenouser-
serviceable parts inside.
• DonotattempttomodifythePDU,includingtheinputplugsandpowercables.
• DonotattempttousethePDUifanypartofitbecomesdamaged.
• DonotattempttomountthePDUtoaninsecureorunstablesurface.
• Neverattempttoinstallelectricalequipmentduringathunderstorm.
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipment
canreasonablybeexpectedtocausethefailureofthelifesupportequipmentorto
signicantlyaffectitssafetyoreffectivenessisnotrecommended.Donotusethis
equipmentinthepresenceofaammableanestheticmixturewithair,oxygenornitrous
oxide.
Features
IEC-320-C19 Outlets:Acceptdirectplug-inofIEC-320-C20
input cords.
IEC-320-C13 Outlets: Acceptdirectplug-inofIEC-320-C14
input cords.
IEC-320-C20 Inlet (PDUH20DV Only):Acceptsdirectplug-in
ofanIEC-320-C19cordsetoradapter.
14-02-329-933047.indb 2 4/23/2014 3:39:24 PM
3
1-3
1-2
1-1
A
B
C
C
A
A
B
B
Installation
Step
1
: Determine Installation
Conguration:ThePDUsupportsfour
primaryinstallationcongurations:1U
Rack,0URack,WallandUnder-Counter.
Choose a configuration and follow the
installation instructions in the appropriate
sectionofStep
1
beforeproceedingtoStep
2
.
Note: Regardless of installation configuration, the user
must determine the fitness of hardware and procedures
before mounting. The PDU and included hardware are
designed for common rack and rack enclosure types
and may not be appropriate for all applications. Exact
mounting configurations may vary.
Step
1-1
: 1U Rack Installation: Attach
thePDUtotherackbyinsertingfour
user-suppliedscrews
A
throughthePDU
mounting brackets
B
and into the mounting
holes of the rack rail as shown.
Step
1-2
: 0U Rack Installation:
Part 1: Remove the screws
C
attaching
themountingbracketstothePDU,change
the orientation of the brackets as shown
andreattachthebrackets.Useonlythe
screws supplied by the manufacturer or
theirexactequivalent(#6-32,1/4”at
head). Part 2:AttachthePDUverticallyby
insertingtwoormoreuser-suppliedscrews
A
throughthePDUmountingbrackets
B
and into mounting points in the rack or rack
enclosure.
Step
1-3
: Wall Installation: After
repeatingPart1above,attachthePDUtoa
stable mounting surface by inserting two or
moreuser-suppliedscrews
A
through the
PDUmountingbrackets
B
and into secure
mounting points on the mounting surface.
Features (continued)
NEMA L6-20P Adapter (PDUH20DV Only): Connects to a
NEMAL6-20Routlet.
14-02-329-933047.indb 3 4/23/2014 3:39:25 PM

Produkspesifikasjoner

Merke: Tripp Lite
Kategori: Ikke kategorisert
Modell: PDUH20DV
Vekt: 1410 g
Bredde: 438.2 mm
Dybde: 95.2 mm
Høyde: 44.4 mm
LED-indikatorer: Ja
Opprinnelsesland: China
Pakkevekt: 2490 g
Sertifisering: UL 60950 (USA), CSA (Canada), CE (EU)
AC-inngangsfrekvens: 50 - 60 Hz
Kabellengde: 3.7 m
Produktfarge: Sort
Pakkedybde: 510.5 mm
Pakkehøyde: 57.2 mm
Pakkebredde: 276.9 mm
Oppbevaringstemperaturomåde (Celsius): -15 - 50 °C
Bærekraftsertifikater: RoHS
Kroppsmateriale: Metall
Montering: Horisontal
Driftshøyde: 0 - 3000 m
Rack-kapasitet: 1U
Antall AC outlets: 14 AC-utganger
Masterkassens (ytterkassens) GTIN (EAN/UPC): 10037332158960
Masterkassens (ytterkassens) bruttovekt: 14880 g
Masterkassens (ytterkassens) lengde: 528.3 mm
Produkter per masterkasse (ytterkasse): 6 stykker
Masterkassens (ytterkassens) bredde: 365.8 mm
Masterkassens (ytterkassens) høyde: 304.8 mm
Innput-forbindelsestype: NEMA L6-20P, IEC-320 C20
Strøm (maks.): 20 A
AC-utgangstyper: C13 coupler, C19 coupler
Nominell innputspenning: 100-240 V
PDU types: Grunnleggende
Nominell outputspenning: 100-240 V