PoE Maximum Load Meter w/ Voltage & Power Monitor User Manual
 Application Drawing 
Important Safety Warning
DO NOT OPEN
RISK OF ELECTRIC SHOCK
CAUTION
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK,
                   DO NOT REMOVE COVER. NO USER SERVICEABLE
                   PARTS INSIDE. REFER SERVICING TO QUALIFIED
                   SERVICE PERSONNEL.
The Vi00024 Setup
The Smart Choice for Transmission Solutions                       www.vigitron.com
- Read these instructions.
- Keep these instructions.
- Heed all warnings.
- Follow all instructions.
- Do not use this apparatus near water.
- Clean only with a dry cloth.
- Use in accordance with the manufacturer’s instructions.
- To reduce the risk of fire or electrical shock, do not expose these products 
  to rain, moisture, dripping or splashing.
- No objects filled with liquids, such as vases, shall be placed on Vigitron
  equipment.
- DO NOT install the unit in a place where the operating ambient tempera
  ture exceeds 75°C.
- Only use attachments/accessories specified by the manufacturer.
- Unplug this apparatus during lightning storms or when unused for long 
  periods of time.
- Refer all servicing to qualified service personnel. Servicing is required
  when the apparatus has been damaged in any way, such as a power 
  supply cord or plug is damaged, liquid has been spilled, or objects have
  fallen into the apparatus, the apparatus has been exposed to rain or 
  moisture, does not operate normally, or has been dropped.
- The network cable is used as the disconnect device and shall remain
  readily operable.
Vi00024_UM
Vigitron’s patent pending Vi00024 is an innovative test tool that installation 
reliability by measuring PoE capacity at any point of a networks before 
installing a camera. The Vi00024 simulates PoE devices and measures the 
maximum PoE capacity received from the PoE source over the network. It is 
compliant with IEEE 802.3af/at/bt standard up to 74W. 
The Vi00024 operates in both Manual and Auto mode. In manual mode the 
user can manually increase the PoE consumption of the Vi00024 until it 
reaches the maximum available PoE.  In the auto mode, the Vi00024 with 
the push one bottom can measure maximum available PoE in a few 
seconds.
The Vi00024 includes a rechargeable battery that can be charged via a 
USB type C connector using any standard USB charger. It is very low power 
and with a full charge can operate for several days. 
The Vi00024’s compact and light weight construction makes is easy to carry 
and use.  It is easy to use and helps to speed up installations and prevent 
service calls by locating and helping to solve PoE problems. 
The Vi00024 can measure Maximum available PoE up to 74W over standard networks.  
The Vi00024 can measure Maximum available PoE up to 74W over Extended UTP networks.
Cat 5/6
PoE
328 ft. (100m)
PoE
328 ft. (100m)
PoE
328 ft. (100m)
Vi30208
56VDC
Vi10240
Measuring Maximum PoE over an Extended UTP network
Measuring Maximum PoE over a standard network
PoE Switch
Vi00024
Vi2301A
Vi2301A
Vi00024
PoE
Extended UTP
Power
Mate
TM
Turning On
• Hold down the Button to Turn ON the Vi00024 and view “Menu” Selection 
on the display .
• In Selection Menu:
      • Press Once for  .AUTO Mode
    • Press Twice for Manual Mode
Auto Mode
After selecting Auto Mode the Vi00024 will turn on a PoE Load and 
increase the load gradually until the PoE source shuts down due to 
exceeding its maximum load capacity. Then the Vi00024 will display the 
maximum PoE level.
      • Press Twice to exit the  .Auto Mode
Manual Mode
In the    select the load increase mode:Manual Mode
      • Press Once for Class Mode
      • Press Twice for 5W Mode
   Class Mode
     In this mode select the desired PoE Class. 
     • Press Twice to exit Manual/Class Mode.
   5W Mode
     In This mode Press Once each time to increase the PoE load by 5W up
     to 74W.
      • If time out, Press Once to resume operation.
      • Press Twice to exit Manual/5W Mode.
Turning Off
• Hold down the Button for 3 Second to turn off the Vi00024.
• If the Vi00024 is left idle for 1 minute, it will shut down
unit time out
Produkspesifikasjoner
| Merke: | Vigitron | 
| Kategori: | Nettverkskort/adapter | 
| Modell: | Vi00024 | 
Trenger du hjelp?
Hvis du trenger hjelp med Vigitron Vi00024 still et spørsmål nedenfor, og andre brukere vil svare deg
Nettverkskort/adapter Vigitron Manualer
                        
                         3 April 2025
                        
                    
                                                            
                        
                         15 Mars 2025
                        
                    
                                                            
                        
                         15 Mars 2025
                        
                    
                                                            
                        
                         10 Desember 2024
                        
                    
                                                            
                        
                         10 Desember 2024
                        
                    
                                                            Nettverkskort/adapter Manualer
- Vivolink
- ScreenBeam
- Valcom
- Luxul
- EQ-3
- Akasa
- Strong
- GeoVision
- Twelve South
- Asus
- Edimax
- NUVO
- Vantec
- Cudy
- Digitus
Nyeste Nettverkskort/adapter Manualer
                        
                         8 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         31 Mars 2025
                        
                    
                                                            
                        
                         29 Mars 2025
                        
                    
                                                            
                        
                         12 Mars 2025
                        
                    
                                                            
                        
                         11 Mars 2025
                        
                    
                                                            
                        
                         7 Mars 2025