INETS-IOEX-DOOR-BATT
Door Sensor
Installation Guide
Description
The Crestron
®
 INETS-IOEX-DOOR-BATT door sensor detects when a door is open 
or closed and transmits the state to the Crestron control system. The door sensor 
communicates with the control system via the inNET EX
®
 wireless network. The door 
sensor is comprised of two parts: a magnet and a sensor. 
Parts that are included with the INETS-IOEX-DOOR-BATT:
ITEM Qty
Sensor 1
Encapsulated magnet - 11/16 in. x 2-11/16 in. 1
Disc magnet - 1/2 in. Dia. x 1/16 in. L 1
Barrel magnet - 15/64 in. Dia. x 25/32 in. L 1
Double-sided tape - 1/2 in. Dia. 1
Nail - 1 in. 2
Mounting bracket 2
Dry contact connector 1
Paper Clip (Attached to Installation Guide) 1
Additional Resources
Visit the product page on the Crestron website (www.crestron.com) for 
additional information and the latest rmware updates. Click the QR 
code or use a QR reader application on your mobile device to scan the 
QR image.
Install the Door Sensor
The sensor can be recess mounted by placing it into a drilled hole in the top of the door or 
surface mounted by using double-sided tape to adhere it to the face of the door.
To ensure proper operation, the active end of the sensor must be in close proximity to 
the magnet. The active end of the sensor has a hole for the setup button and a notch for 
removing the bottom cover. 
NOTES: 
•  The INETS-IOEX-DOOR-BATT must be installed within range of an inNET EX 
wireless network.
•  If installed in a hard-to-reach location, join the inNET EX wireless network 
before installation. Refer to the  “Operation” section on page 2 for details.
Recess Mount the Sensor
Install the sensor into the top of the door near the strike edge to keep the sensor hidden 
from view. 
NOTE: If necessary, the sensor can be installed in the door frame jamb and the magnet 
may be secured to the door. 
Install the Sensor
1.  Use a drill and a 7/8 in. diameter drill bit to make a 2-11/16 in. (68 mm) deep hole in 
the top of the door. The hole should be centered in the top of the door near the strike 
edge (latch side). Ensure that the hole is straight to prevent binding.
Top of door
Door face
Strike edge of door (latch side)
Drill a 7/8 in. diameter, 
2-11/16 in. (68 mm) deep 
mounting hole. 
2.  Remove one side of the preinstalled double-sided tape from a mounting bracket 
and then secure the mounting bracket to the side of the sensor. When securing the 
bracket to the sensor, ensure that the tabs on the mounting bracket face away from 
the active end of the sensor. Repeat for the other mounting bracket.
Active end 
of sensor
The mounting bracket tabs 
must face away from the 
active end of the sensor.
3.  Insert the sensor and bracket assembly into the hole. 
4.  Secure the sensor and bracket assembly using two nails (supplied).
Insert the sensor into the 
door and secure with nails.
Strike edge of door 
(latch side)
Install the Disc or Barrel Magnet
Place a disc or barrel magnet on the door frame opposite the active end of the sensor. The 
distance between the active end of the sensor and the magnet should be 1/8 in. or less. 
NOTE: To ensure proper operation, a recess may need to be made in the door frame to 
maintain proper distance between the magnet and the door sensor.
Install the magnet:
1.  Remove one side of the double-sided tape and place it onto a at side of the 
magnet.
2.  Remove the other side of the double-sided tape and secure the magnet to the door 
frame.
Surface Mount the Sensor
Secure the sensor to the face of the door. The sensor should be located at the top of the 
door so that it is near the door jamb and strike edge. The sensor can be installed vertically 
or horizontally on the face of the door.
NOTE: If necessary, the sensor can be secured to the door frame jamb and the magnet 
may be secured to the door. 
Install the Sensor
1.  Remove one side of the double sided tape from the sensor.
2.  Secure the sensor to the face of the door.
Top of door
Door face
Strike edge of door (latch side)
Place sensor here
Door swing
Install the Encapsulated Magnet
The encapsulated magnet should be placed on the door frame with the marked “M” on 
the magnet adjacent to the active end of the sensor. The encapsulated magnet should be 
parallel to the sensor and placed 1/8 in. from the sensor when the door is closed.
NOTE: If necessary, the magnet end can be determined by moving the case of the 
encapsulated magnet near a ferrous metal object.
Install the encapsulated magnet:
1.  Remove one side of the double sided tape from the encapsulated magnet.
2.  Secure the encapsulated magnet to the door frame. 
Produkspesifikasjoner
| Merke: | Crestron | 
| Kategori: | sensor | 
| Modell: | INETS-IOEX-DOOR-BATT | 
Trenger du hjelp?
Hvis du trenger hjelp med Crestron INETS-IOEX-DOOR-BATT still et spørsmål nedenfor, og andre brukere vil svare deg
sensor Crestron Manualer
                        
                         1 April 2025
                        
                    
                                                            sensor Manualer
- Fluke
- IFM
- Festo
- Panasonic
- Chauvin Arnoux
- Moen
- Hikvision
- Jung
- Oliveri
- Vimar
- Carrier
- Sensirion
- Berker
- Phoenix Contact
- Metz Connect
Nyeste sensor Manualer
                        
                         15 September 2025
                        
                    
                                                            
                        
                         9 September 2025
                        
                    
                                                            
                        
                         30 August 2025
                        
                    
                                                            
                        
                         24 August 2025
                        
                    
                                                            
                        
                         23 August 2025
                        
                    
                                                            
                        
                         6 August 2025
                        
                    
                                                            
                        
                         6 August 2025
                        
                    
                                                            
                        
                         3 August 2025
                        
                    
                                                            
                        
                         3 August 2025
                        
                    
                                                            
                        
                         3 August 2025