The 85RF II High Frequency Probe (the Probe) transforms a
dc voltmeter into a high frequency (100 kHz to 500 MHz) ac
voltmeter. Conversion from ac to dc is done on a one-to-one
basis and includes a range of 0.25 V rms to 30 V rms. The
of a sine wave input.
Safety
Symbol Description
W
See Instruction Sheet.
X
Hazardous voltage.
~
Do not dispose of this product as
unsorted municipal waste. Go to Fluke’s
website for recycling information.
WXWarning
To prevent possible electrical shock, fire, or personal
injury:
Examine the case before you use the Product.
Look for cracks or missing plastic. Carefully
look at the insulation around the terminals.
Limit operation to the specified measurement
category, voltage, or amperage ratings.
Do not touch voltages >30 V ac rms, 42 V ac
peak, or 60 V dc.
Do not use the Product around explosive gas,
vapor, or in damp or wet environments.
Do not use and disable the Product if it is
damaged.
Use the Product only as specified, or the
protections supplied by the Product can be
compromised.
Do not exceed the Measurement Category (CAT)
rating of the lowest rated individual component
of a Product, Probe, or accessory.
Keep fingers behind the finger guards on the
Probes.
Do not connect directly to mains.
PN 4096837
September 2011, Rev. 1, 12/11
©2011 Fluke Corporation, Printed in the U.S.A. All product names are
trademarks of their respective companies. Specifications are subject to change
without notice.
®

Produkspesifikasjoner

Merke: Fluke
Kategori: Ikke kategorisert
Modell: 85RF

Trenger du hjelp?

Hvis du trenger hjelp med Fluke 85RF still et spørsmål nedenfor, og andre brukere vil svare deg