KNX CO², humidity and temperature sensor (surface mounted)
Version: Feb-11 (Subject to change) Page 1 of 30
KNX CO², humidity and temperature
sensor (surface mounted)
KNX CO2, humidity and temperature sensor Order no. MTN6005-0001
KNX CO², humidity and temperature sensor (surface mounted)
Version: Feb-11 (Subject to change) Page 2 of 30
Contents
KNX CO², humidity and temperature sensor (surface mounted) ............................. 1
1 Functional characteristics ................................................................................................ 3
1.1 Operation .................................................................................................................. 3
1.2 Benefits ...................................................................................................................... 3
2 Technical data ................................................................................................................... 4
2.1 Technical data ........................................................................................................... 4
3 The application program "CO2,humidity & temperature sensor 4216/1.0" ................. 5
3.1 Selection in the product database ........................................................................... 5
3.2 Communication objects ........................................................................................... 6
3.2.1 Description of objects ............................................................................................. 9
3.3 Parameters .............................................................................................................. 14
3.3.1 Overview .............................................................................................................. 14
3.3.2 The Readings parameter page ............................................................................. 15
3.3.3 The CO
2
threshold parameter page ....................................................................... 16
3.3.4 The 1, 2, 3 CO
2
thresholds parameter pages ........................................................ 17
3.3.5 The ventilation CO
2
threshold parameter page ..................................................... 19
3.3.6 The CO
2
scenes parameter page ............................................................................ 20
3.3.7 The humidity threshold parameter page .............................................................. 21
3.3.8 The 1, 2, 3 humidity thresholds parameter pages ................................................. 22
3.3.9 The Humidity ventilation parameter page ........................................................... 24
3.3.10 The Relative humidity scenesparameter page ................................................. 25
3.3.11 Temperature threshold parameter page ........................................................... 26
4 Appendix .......................................................................................................................... 28
4.1 Hysteresis ................................................................................................................ 28
4.2 Switching response of thresholds for CO
2
and humidity.................................... 28
4.3 Fan control .............................................................................................................. 29
4.4 Relative humidity ................................................................................................... 29
4.5 CO
2
guide values ..................................................................................................... 30
KNX CO², humidity and temperature sensor (surface mounted)
Version: Feb-11 (Subject to change) Page 3 of 30
1 Functional characteristics
The device is a combined sensor for CO
2,
temperature and humidity measurement
(relative humidity).
It is designed to monitor air quality in conference/meeting rooms, offices, schools/
kindergartens, passive or low energy houses and living rooms without controlled ventilation.
1.1 Operation
The device does not have to be operated manually.
The LED and the push button for the physical address are accessible when cover is removed.
If necessary, the push button can be reached with a thin screwdriver via the upper ventilation
slot.
CAUTION: Do not drop the device!
Severe shocks reduce the accuracy of the highly sensitive CO2 sensor.
1.2 Benefits
Combined measurement of temperature, humidity and CO2 content in one device.
Power supply via bus connection, no mains power required.