OPERATION MANUAL
Air Conditioners
DUCTED SYSTEM
R-32 Series
MODELS
(Ceiling concealed duct type)
IMPORTANT NOTE:
TCD Series cannot be install underfloor.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
TCD71D1HWH-DV
TCD85D1HWH-DV
TCD100D1HWH-DV
TCD125D1HWH-DV
TCD140D1HWH-DV
TCD160D1HWH-DV
Operation Manual
Ducted Air Conditioners1
Operation Manual
SAFETY CONSIDERATIONS
We recommend that you read this operation manual carefully before using your air conditioner to gain full advantage of the functions and to
avoid malfunction due to mishandling or incorrect operation.
After reading, keep this manual in a place where any user can read at any time. Furthermore, make certain that this operation manual is handed
to a new user if required.
The precautions described below are WARNINGS and CAUTIONS. These are very important precautions concerning safety.
Be sure to observe all of them without fail.
WARNING............... ...Failure to observe a warning may result in death, injury or damage to the equipment.
CAUTION................. ...Failure to observe a caution may result in injury or damage to the equipment.
WARNING
·lf the air conditioner appears to be operating abnormally (smell of
something burning, etc.), switch the air conditioner off at the main
switch and contact the dealer where you purchased the air condi-
tioner. Continued operation under such circumstances may result in a
failure, electric shock or fire.
·Only use a qualified installer for installation of the air conditioner.
Incorrect installation may result in a water leakage,electric shock or
fire.
·Ask you dealer to carry out improvements, repairs and maintenance.
Incorrect improvements, repairs and maintenance may result in a
water leakage, electric shock or fire.
·Never remove any fixed covers on the indoor or outdoor unit.
Removal of the covers may expose fast moving fan blades or
electrical components operating at a hazardous voltage. Contact with
the blades or high voltage components may result in injury or electric
shock.
·Precaution against refrigerant leakage. If the air conditioner is to be
installed in an unventilated room it is necessary to take proper
measures to ensure that the allowable refrigerant concentration per
cubic metre cannot be exceeded, should a refrigerant leak occur. If
the allowable refrigerant concentration is exceeded, drowsiness or
asphyxiation due to oxygen deficiency may occur.
·For installation of separately sold component parts, ask a specialist
only. Be sure to use separately sold component parts designated by
TCL, Incomplete installation performed by yourself may result in a
water leakage, electric shock or fire.
·Ask your dealer to move and reinstall the air conditioner. Incomplete
installation may result in a water leakage, electric shock or fire.
·Never insert any objects into the openings in the indoor or outdoor
unit. This may damage the product or result in injury or death to the
person inserting the object.
·When the air conditioner is used in combination with burners or
heaters, ensure sufficient ventilation. Insufficient ventilation may
result in an oxygen deficiency accident.
·Regularly check the quality of the foundation blocks. If they are left
in a damaged condition, the unit may fall and result in injury.
· Do not place or use a flammable spray can near the air condi-
tioner. Doing so may result in a fire.
·To clean the air conditioner, stop the operation and switch the
power off at the main switch. Otherwise, an electric shock and
injury may result.
· Do not expose the indoor unit or remote controller to rain or
moisture. Water or other fluids on the electrical components may
result in fire or electric shock.
·Always replace any blown fuse with a fuse of the same specifica-
tion. The use of the wrong type fuse may allow the electrical wiring
to overheat and catch on fire. If the correct type of fuse continues
to blow contact your installer or electrician.
·Do not place a burner or heater in a place directly exposed to the
airstream from the air conditioner. Incomplete combustion of the
burner or heater may result.
·Do not wash the air conditioner with water. An electric shock may
result.
·Do not install the air conditioner in an area where flammable gas
may be present. If the gas leaks out and stays around the air
conditioner, a fire may break out.
·Avoid prolonged exposure of your body to direct streams of cold
air. Your physical condition may deteriorate.
·This product contains Refrigerant Type: R32.
·R32 Classification as Flammable Refrigerant with Category1
Flammable Gas (in WHS Regulations), and Division 2.1Flammable
Gas in Transport Code.
·Do not charge R32 into systems other than those designated
forR32.
·Do not charge R32 system with oil other than those designated
for R32.
·Do not use a reclaim cylinder other than an R32 reclaim cylinder.
·Do not install pipe work with diameters that are not specified for
that model.
·Do not forget to add additional refrigerant if required.
Operation Manual
Ducted Air Conditioners 2
CAUTION
·Do not use the air conditioner for other purposes. Do not use the air
conditioner for special applications such as storage of foods, animals
and plants, precision machines and art objects. Deterioration of
quality may result.
·Ensure drain piping is completed. Incomplete piping may result in a
water leakage.
·Do not expose animals and plants directly to the airstream from the
outdoor unit. Adverse influence to animals and plants may result.
·Never operate the air conditioner without the return air filter(s) in
place. Operating the unit without the filter(s) will allow dust to enter
the indoor unit and build up on the heat exchanger coil and fan
motor. This will cause a malfunction of the unit which will not be
covered by Warranty.
·This electrical appliance is not intended for use by young children
or infirm persons without supervision. Young children should be
supervised to ensure that they do not play with the outdoor unit.









Produkspesifikasjoner

Merke: TCL
Kategori: luftkondisjonering
Modell: TCD85D1HWH-DV

Trenger du hjelp?

Hvis du trenger hjelp med TCL TCD85D1HWH-DV still et spørsmål nedenfor, og andre brukere vil svare deg




luftkondisjonering TCL Manualer

luftkondisjonering Manualer

Nyeste luftkondisjonering Manualer