Tripp Lite SRCOOL12K Bruksanvisning
Tripp Lite
luftkondisjonering
SRCOOL12K
Les nedenfor 📖 manual på norsk for Tripp Lite SRCOOL12K (52 sider) i kategorien luftkondisjonering. Denne guiden var nyttig for 3 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere
Side 1/52

1
Portable Air Conditioning Unit
SRCOOL12K – Series Number: AG-0073 (120V, 60 Hz)
SRXCOOL12K – Series Number: AG-00A0 (230V, 50 Hz)
SRXCOOL12KA – Series Number: AG-0533 (230V, 50 Hz)
SRXCOOL12KB – Series Number: AG-00A0 (230V, 50 Hz)
Owner’s Manual
Introduction 2
Important Safety Instructions 2
Features 4
Installation 5
Operation 9
Cleaning and Maintenance 10
Troubleshooting 11
Storage and Service 12
Circuit Diagrams 12
Warranty and Product Registration 13
Regulatory Compliance 13
Español 14
Français 27
Русский 40
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2020 Tripp Lite. All rights reserved.
WARRANTY REGISTRATION
Register your product today and be
automatically entered to win an ISOBAR
®
surge protector in our monthly drawing!
tripplite.com/warranty

SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
4
7
X
5
0
MASTR
STACK
SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
MASTR
STACK
SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
MASTR
STACK
SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
MASTR
STACK
SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
MASTR
STACK
SYST
RPS
STAT
DUPLX
SPEED
MODE
1
5
X
3
1
X
3
3
X
MASTR
STACK
4
7
X
5
0
4
7
X
5
0
4
7
X
5
0
4
7
X
5
0
4
7
X
5
0
2
Introduction
The self-contained Portable Air Conditioning Unit provides 12,000 BTU (up to 3.4 kW) of supplemental cooling capacity. Designed for IT
environments, it’s ideal for cooling overheated rack enclosures, IT equipment hot spots and network closets without access to facility air
conditioning. The Portable Air Conditioning Unit can focus cool air through its flexible cooling duct or cool a small room through its louvered vent.
It also filters and dehumidifies air to improve operating conditions and equipment reliability. Condensate is re-evaporated for drip-free operation,
so you won’t waste time emptying water collection tanks. The self-contained design does not require any plumbing or special circuits, so setup is
quick and easy. Eco-friendly R410A refrigerant meets environmental standards worldwide.
Recommended Applications:
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation
and storage of this product. Failure to heed these warnings may affect your warranty.
Warnings
• The individual user should determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual
applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of this device
for any specific application.
• Install the unit indoors, away from extreme temperatures or humidity, direct sunlight, dust and conductive contaminants.
• Leave adequate space around the unit for ventilation, with rear and vented sides not less than 20 inches (51 cm) from walls or other
obstacles.
• Install the unit on a flat surface with a gradient no more than 10°.
• Connect the unit directly to a grounded AC power outlet. Failure to do so may cause an electric shock or fire.
• This unit is designed to supply supplemental cooling for localized hot spots.
• The power supply for the unit must be rated in accordance with the unit’s nameplate.
• Do not modify the plug nor use an adapter that would eliminate the ground connection.
• Do not use an extension cord to connect the unit to an AC outlet. Use only the power cord that came with the unit.
• Comply with all applicable wiring and safety regulations, such as National Electrical Code (NEC) in the United States.
• Do not plug additional equipment into the outlet where the unit is plugged in. Overloading the outlet may cause an electric shock or fire.
• Do not attempt to turn the unit on or off by connecting or disconnecting the AC plug. A serious electric shock may occur. Use the ON/OFF
button to turn the unit on or off.
• Turn the unit off and unplug it from the AC outlet before performing maintenance.
• Before connecting the unit to a dedicated drainage system, turn it off and unplug it. There is a risk of electric shock while the unit is plugged in.
• Do not use thinners, alcohol, detergents or abrasive brushes to clean the unit’s cabinet. These items may damage the cabinet.
• Do not pour water over the unit. This may cause an electric shock and damage the unit.
• Do not operate the unit without the air filter. This may cause dust accumulation that may damage the unit.
• Do not attempt to operate the unit in a room with inadequate air circulation. Provide makeup air in accordance with applicable building codes.
• Do not place objects on top of the unit.
• Do not operate your air conditioner in a wet room, such as a bathroom or laundry room.
• The applicable operating temperature range for this unit is 17°-35° (SRX Models only).
1. Cooling an overheated rack enclosure. 2. Cooling an equipment hot spot inside or
outside a rack enclosure.
3. Cooling a small room.

3
Important Safety Instructions
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
• Children should be supervised to ensure that they do not play with the appliance.
• Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life
support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a
flammable anesthetic mixture with air, oxygen or nitrous oxide.
Impedance declaration
We declare the model AG-0533 (SRXCOOL12KA) be connected only to a supply with the relevant system impedance no more than 0.338 ohm.
Restrictions to connection may be imposed by the supply authority on the use of equipment if the actual relevant system impedance at the inter-
face point on the user’s premise exceeds 0.338 ohm.
Produkspesifikasjoner
Merke: | Tripp Lite |
Kategori: | luftkondisjonering |
Modell: | SRCOOL12K |
Vekt: | 33520 g |
Bredde: | 300 mm |
Dybde: | 505 mm |
Høyde: | 778 mm |
Opprinnelsesland: | China |
Pakkevekt: | 36740 g |
Produktfarge: | Sort |
Pakkedybde: | 840.7 mm |
Pakkehøyde: | 736.6 mm |
Pakkebredde: | 391.2 mm |
Harmonisert system (HS)-kode: | 8415.82.0105 |
Viftens ytelseseffekt: | 329 cfm |
Masterkassens (ytterkassens) bruttovekt: | 36740 g |
Masterkassens (ytterkassens) lengde: | 840.7 mm |
Produkter per masterkasse (ytterkasse): | 1 stykker |
Masterkassens (ytterkassens) bredde: | 391.2 mm |
Masterkassens (ytterkassens) høyde: | 736.6 mm |
Trenger du hjelp?
Hvis du trenger hjelp med Tripp Lite SRCOOL12K still et spørsmål nedenfor, og andre brukere vil svare deg
luftkondisjonering Tripp Lite Manualer
17 August 2025
17 August 2025
17 August 2025
16 August 2025
16 August 2025
luftkondisjonering Manualer
- luftkondisjonering Haier
- luftkondisjonering LG
- luftkondisjonering BEKO
- luftkondisjonering Exquisit
- luftkondisjonering Danby
- luftkondisjonering Gree
- luftkondisjonering Nabo
- luftkondisjonering AEG
- luftkondisjonering Cecotec
- luftkondisjonering Samsung
- luftkondisjonering Delonghi
- luftkondisjonering Kogan
- luftkondisjonering Midea
- luftkondisjonering Panasonic
- luftkondisjonering Olimpia Splendid
- luftkondisjonering Frigidaire
- luftkondisjonering Dimplex
- luftkondisjonering Ufesa
- luftkondisjonering Einhell
- luftkondisjonering Mitsubishi
- luftkondisjonering Philco
- luftkondisjonering Klarstein
- luftkondisjonering Wilfa
- luftkondisjonering Heinner
- luftkondisjonering Argoclima
- luftkondisjonering Primo
- luftkondisjonering Broan
- luftkondisjonering Eurom
- luftkondisjonering Honeywell
- luftkondisjonering Crosley
- luftkondisjonering Ariston Thermo
- luftkondisjonering Berner
- luftkondisjonering Ivation
Nyeste luftkondisjonering Manualer
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025
17 August 2025