Viking E-1600A-TP-EWP Bruksanvisning

Viking Intercomsystem E-1600A-TP-EWP

Les nedenfor 📖 manual på norsk for Viking E-1600A-TP-EWP (12 sider) i kategorien Intercomsystem. Denne guiden var nyttig for 3 personer og ble vurdert med 4.4 stjerner i gjennomsnitt av 2 brukere

Side 1/12
For use with Talk-A-Phone or GAI-Tronics tower, stan-
chion, pedestal, surface, wall and flush mount enclo-
sures. Code Blue towers require redrilling and tapping.
The E-1600A-TP-EWP, E-1600A-TP2-EWP or
E-1600A-GT-EWP will call up to 5 programmable emer-
gency numbers, as well as 2 central station numbers
and send a digital announcement to identify the location
of the emergency call. The included BLK-4 control
module will supply a contact or switched 12V DC to acti-
vate a strobe light. In addition, the E-1600A-TP2-EWP
features a second “Info” button that will dial up to 3 non-
emergency numbers.
Though the strobe requires external power to operate,
voice communication is possible during power failures.
All phone numbers, location numbers, voice announce-
ment and programming parameters are stored in
non-volatile memory. No batteries are required.
The E-1600A-TP-EWP, E-1600A-TP2-EWP and
E-1600A-GT-EWP are equipped with Enhanced
P
P
r
r
a
a
c
c
t
t
i
i
c
c
e
e
S
S
E
E
C
C
U
U
R
R
I
I
T
T
Y
Y
A
A
N
N
D
D
C
C
O
O
M
M
M
M
U
U
N
N
I
I
C
C
A
A
T
T
I
I
O
O
N
N
S
S
O
O
L
L
U
U
T
T
I
I
O
O
N
N
S
S
Phone Power: Telephone line powered. Minimum 24V DC talk battery
voltage, with a minimum loop current of 20mA. Loop current may be
boosted on low current lines with a Viking Model TBB-1B talk battery
booster (DOD 632).
BLK-4 Control Module: 120V AC/12V DC 500mA, UL listed adapter pro-
vided
Dimensions: See Installation
Shipping Weight: 6.4 lbs (2.9 kg)
Mounting: Flush mount to Talk-A-Phone ETP towers, wall mounts, boxes
and pedestals
Environmental: -30°F to 170°F (-34°C to 77°C) with up to 100% con-
densing humidity
Material: .105” (12 gauge) brushed Marine grade 316 stainless steel
Connections: Color-coded wires with gel-filled butt connectors
• Replacing weather damaged Talk-A-Phone or GAI-Tronics
panel phones
• Campus Security Sites
Area of Refuge sites
• Parking Ramps/Lots
Automated Tellers (ATM)
• Entryways
• Roadside Emergency Sites
• Stairwells in Public Buildings
TECHNICAL
TECHNICAL
A
A
p
p
p
p
l
l
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
S
S
p
p
e
e
c
c
i
i
f
f
i
i
c
c
a
a
t
t
i
i
o
o
n
n
s
s
Direct Physical Replacement for: Talk-A-Phone models ETP-400V and
ETP-400DV, GAI-Tronics models 397-001, 397-002, 397-003 and 397-004
E-1600A-TP-EWP
E-1600A-TP-EWP
E-1600A-TP2-EWP
E-1600A-TP2-EWP
E-1600A-GT-EWP
E-1600A-GT-EWP
ADA Emergency Phone Replacements
for Talk-A-Phone and GAI-Tronics
June 29, 2023
New Automatic Noise Canceling (ANC) feature for proper opera-
tion in noisy environments
• Enhanced Weather Protection (EWP), EWP products are designed to
meet IP66 Ingress Protection Rating, see DOD 859
• Meets ADA requirements for Emergency Phones:
- Automatically lights the “Call Connected” LED
- Transmits a unique location I.D. code or voice announcement
- Grade 2 Braille label for the visually impaired
• Non-volatile digital voice announcer with 16 seconds of voice memory
• Provides contact or switched 12V DC for controlling a strobe light
Advanced call progress detection
• Handsfree operation
• Phone line powered emergency phone (BLK-4 requires power)
• Non-volatile memory (no batteries required)
• Marine grade 316 stainless steel prevents corrosion
• Dials up to 5 emergency numbers
E-1600A-TP2-EWP can also dial up to 3 non-emergency “Info” num-
bers
• Cycles through backup phone numbers on busy or no-answer
• Hangs up on CPC, silence, busy signal, dial tone, time-out or touch
tone command
• Programmable to auto-answer on incoming calls
• Remotely programmable
• Extended temperature range (-30°F to 170°F)
• Central Station Monitoring capability (dials two numbers)
• Separate central station voice speed dial number
• Optional PB-100 Polling System available
• High visibility, vandal and weather resistant
F
F
e
e
a
a
t
t
u
u
r
r
e
e
s
s
CAUTION - When installing on an analog extension of a phone system:
Some phone systems do not conform to analog telecom standards and might
not be compatible with the 1600A Series emergency phones. For a detailed
description of the telephone line specifications required for any of the 1600A
Series phones, see DOD 869.
E-1600A-TP-EWP E-1600A-TP2-EWP
Material: Brushed 316 Stainless Steel
E-1600A-GT-EWP
Weather Protection (EWP) for outdoor installations where
the unit is exposed to precipitation or condensation. EWP
products feature foam rubber gaskets and boots, sealed
connections, gel-filled butt connectors, as well as ure-
thane or thermal plastic potted circuit boards with inter-
nally sealed, field-adjustable trim pots and DIP switches
for easy on-site programming. For more information, see
DOD 859.

Produkspesifikasjoner

Merke: Viking
Kategori: Intercomsystem
Modell: E-1600A-TP-EWP
Vekt: 2900 g
Bredde: 241 mm
Dybde: 51 mm
Høyde: 299 mm
Plassering: Vegg
Tilkoblingsteknologi: Koblet med ledninger (ikke trådløs)
Sertifisering: EWP\nIP66\nFCC Part 15\nADA
Antall knapper: 1
Produktfarge: Rustfritt stål
Driftstemperatur (T-T): -26 - 54 °C
Kroppsmateriale: Rustfritt stål
Internasjonal beskyttelses (IP)-kode: IP66
Utendørsenhetens strømtype: AC/DC
Innendørsenhetens strømtype: AC/DC
Enkel installering: Ja

Trenger du hjelp?

Hvis du trenger hjelp med Viking E-1600A-TP-EWP still et spørsmål nedenfor, og andre brukere vil svare deg