ioSafe 1520+ Bruksanvisning

ioSafe Server 1520+

Les nedenfor 📖 manual på norsk for ioSafe 1520+ (28 sider) i kategorien Server. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere

Side 1/28
ioSafe 1520+
User Manual
A8-7530-00 Rev 1.0
©2021 CRU Data Security Group, LLC. ALL RIGHTS RESERVED.
This User Manual contains proprietary content of CRU Data Security Group, LLC (“CDSG”) which is protected by copyright, trademark,
and other intellectual property rights.
Use of this User Manual is governed by a license granted exclusively by CDSG (the “License”). Thus, except as otherwise expressly
permitted by that License, no part of this User Manual may be reproduced (by photocopying or otherwise), transmitted, stored (in a
database, retrieval system, or otherwise), or otherwise used through any means without the prior express written permission of CDSG.
Use of the full ioSafe 1520+ product is subject to all of the terms and conditions of this User Manual and the above referenced
License.
CRU
®
, ioSafe
®
, Protecting Your Data™, and No-Hassle™ (collectively, the “Trademarks”) are trademarks owned by CDSG and are
protected under trademark law. This User Manual does not grant any user of this document any right to use any of the Trademarks.
Kensington
®
is a registered trademark of Kensington Computer Products Group. Synology
®
is a registered trademark of Synology, Inc.
This document does not grant any user of this document any right to use any of the Trademarks.
Product Warranty
CDSG warrants this product to be free of significant defects in material and workmanship for a period of two (2) years from the original
date of purchase. CDSG’s warranty is nontransferable and is limited to the original purchaser.
Limitation of Liability
The warranties set forth in this agreement replace all other warranties. CDSG expressly disclaims all other warranties, including but not
limited to, the implied warranties of merchantability and fitness for a particular purpose and non-infringement of third-party rights with
respect to the documentation and hardware. No CDSG dealer, agent, or employee is authorized to make any modification, extension,
or addition to this warranty. In no event will CDSG or its suppliers be liable for any costs of procurement of substitute products or
services, lost profits, loss of information or data, computer malfunction, or any other special, indirect, consequential, or incidental
damages arising in any way out of the sale of, use of, or inability to use any CDSG product or service, even if CDSG has been advised
of the possibility of such damages. In no case shall CDSG’s liability exceed the actual money paid for the products at issue. CDSG
reserves the right to make modifications and additions to this product without notice or taking on additional liability.
FCC Compliance Statement: “This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.”
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be required to correct the interference at this own
expense.
In the event that you experience Radio Frequency Interference, you should take the following steps to resolve the problem:
1. Ensure that the case of your attached drive is grounded.
2. Use a data cable with RFI reducing ferrites on each end.
3. Use a power supply with an RFI reducing ferrite approximately 5 inches from the DC plug.
4. Reorient or relocate the receiving antenna.
Table of Contents
1. Introduction ............................................................................................................................ 4
2. General Information ................................................................................................................ 5
2.1. Safety Information ........................................................................................................ 5
2.2. Package Contents ........................................................................................................ 5
2.3. Identifying Parts ........................................................................................................... 6
2.4. LED Behavior ............................................................................................................... 7
3. Hardware Installation ............................................................................................................... 8
3.1. Tools and Parts for Drive Installation .............................................................................. 8
3.2. SATA Drive Installation .................................................................................................. 8
3.3. M.2 NVMe SSD Cache Installation ............................................................................... 12
3.4. Replace Memory Modules ........................................................................................... 14
3.5. Connecting the ioSafe 1520+ ....................................................................................... 16
4. Install Synology DiskStation Manager ...................................................................................... 18
5. Connect and Log in to Synology DiskStation Manager .............................................................. 20
6. Using Synology DiskStation Manager ...................................................................................... 22
7. Replace System Fans ............................................................................................................ 23
8. Product Support and Data Recovery Service ........................................................................... 24
8.1. Activate Data Recovery Service Protection ................................................................... 24
8.2. ioSafe No-Hassle Warranty .......................................................................................... 24
8.3. Data Recovery Procedure ............................................................................................ 24
8.4. Contact ioSafe Support ................................................................................................ 25
Appendix A. Hardware Specifications .......................................................................................... 26
ioSafe 1520+ User Manual 3

Produkspesifikasjoner

Merke: ioSafe
Kategori: Server
Modell: 1520+
Vekt: 29000 g
Bredde: 406 mm
Dybde: 483 mm
Høyde: 534 mm
Prosessorfrekvens: 1.5 GHz
Prosessorfamilie: Intel® Celeron®
USB-port: Ja
Sertifisering: EMI Standard: FCC Part 15 Class A, EMC Standard: EN55024, EN55032, RCM
Internminne: 8 GB
Intel® 64: Ja
Maksimal støttet lagringskapasitet: 14 TB
RAID-støtte: Ja
AC-inngangsspenning: 100-240 V
AC-inngangsfrekvens: 50 - 60 Hz
Støttede filsystemer: BTRFS, FAT, HFS+, NTFS, exFAT, ext3, ext4
Online RAID-migrering: Ja
Produktfarge: Sort
Prosessorkjerner: 4
Internminnetype: DDR3L
Operativsystemprogramvare 04: DSM
Kabler inkludert: AC, LAN (RJ-45)
Antall ethernets-/bredbåndstilkoblinger (RJ-45): 5
Driftstemperatur (T-T): 5 - 35 °C
Oppbevaringstemperaturomåde (Celsius): -20 - 60 °C
Lagringsrelativ fuktighet: 0 - 100
Bærekraftsertifikater: CE, Federal Communications Commission (FCC), RoHS
prosessorprodusent: Intel
Modell/Type: NAS
Strømforsyningsenhet (PSU) kapasitet: 150 W
Ethernet LAN dataoverføringshastigheter: 10,100,1000 Mbit/s
RAID-nivåer: 0, 1,5, 6,10, JBOD
ECC: Nei
Antall lagringsdrivere som støttes: 5
Ethernet/bredbåndsforbindelse: Ja
Grafikkadaptermodell om bord: Intel® UHD Graphics 600
Chassis-type: Desktop
Relativ luftfuktighet under drift (H-H): 0 - 95
Prosessormodell: J4125
Form for nedkjøling: Aktiv
Kabellåsport: Ja
Kabellåstype: Kensington
Viftediameter: 120 mm
Antall vifter: 2 vifter
Fullstendig installert lagringskapasitet: 0 TB
Lagermedia kapasitet: 0 GB
Installert lagringsdrivertype: Nei
Støttet lagrings drive type: HDD & SSD
Backup-funksjon: Ja
Enhanced Intel SpeedStep Technology: Ja
Boostfrekvens prosessor: 2.3 GHz
Processor cache: 4 MB
Prosessortråder: 4
Intel® Virtualization Technology (VT-x): Ja
Integrerte alternativer tilgjengelige: Nei
Intel® VT-x with Extended Page Tables (EPT): Ja
Inaktive tilstander: Ja
Execute Disable Bit: Ja
Prosessorkonfigurasjon (maks.): 1
Intel Virtualisering Technology for Directed I/O (VT-d): Ja
Grensesnitt for lagringsdriver: Serial ATA, Serial ATA II
Strømforsyningens plassering: Innebygget
Vifte diameter 2: 120 mm
Hot-swap drive bays: Ja
Lagerdrivere installert: Nei

Trenger du hjelp?

Hvis du trenger hjelp med ioSafe 1520+ still et spørsmål nedenfor, og andre brukere vil svare deg