Lithium (non-replaceable sealed in) Battery-Operated
Optical Smoke Alarm with HUSH
TM
Control to temporarily
silence nuisance alarms.
Thank you for purchasing this smoke alarm. It is an
important part of your family’s home safety plan. You can
trust this product to provide the highest quality safety
protection. We know you expect nothing less when the lives
of your family are at stake.
10Y29
Smoke Alarm
User’s Guide
For model: 10Y29
Smoke Alarm Model Number
(located on back of alarm):
Date Code (located on back of alarm):
Kidde recommends replacing this
alarm ten years from the date code.
Date of Purchase:
Where Purchased:
21008570 rev.B FHK P/N:0308-7201-02
0086-CPD-535595
Installation instructions and product information can be
found within this manual.
EN14604:2005
Licence No. KM524754
0308-7201-02(21008570B)_En.qxd:_ 2012.2.16 12:10 PM Page
Ionisation sensing alarms may detect invisible fire particles (associated with fast
flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may
detect visible fire particles (associated with slow smouldering fires) sooner than
ionisation alarms. Home fires develop in different ways and are often unpredictable.
For maximum protection, Kidde recommends that both Ionisation and Photoelectric
alarms be installed.
IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS
MANUAL NEAR THE ALARM FOR FUTURE REFERENCE.
CONTENTS OF THIS MANUAL
1 -- RECOMMENDED LOCATIONS FOR ALARMS
2 -- LOCATIONS TO AVOID
3 -- INSTALLATION INSTRUCTIONS
4 -- OPERATION AND TESTING
5 -- NUISANCE ALARMS
6 -- MAINTENANCE
7 -- LIMITATIONS OF SMOKE ALARMS
8 -- GOOD SAFETY HABITS
9 -- KIDDE RECOMMENDATIONS
10 -- SERVICE AND WARRANTY
ENVIRONMENTAL PROTECTION
Waste electrical products should not be disposed of with household
waste. Please recycle where facilities exist. Check with Local Authority
or Supplier for recycling advice.
1. RECOMMENDED LOCATIONS FOR ALARMS
Locate the first alarm in the immediate area of the bedrooms. Try to monitor the
exit path as the bedrooms are usually farthest from the exit. If more than one
sleeping area exists, locate additional alarms in each sleeping area.
Locate additional alarms to monitor any stairway as stairways act like chimneys for
smoke and heat.
Locate at least one alarm on every floor level.
Locate an alarm in every bedroom.
Locate an alarm in every room where electrical appliances are operated excluding
kitchens (i.e. portable heaters or humidifiers).
Locate an alarm in every room where someone sleeps with the door closed.
The closed door may prevent an alarm not located in that room from waking the
sleeper.
Smoke, heat, and combustion products rise to the ceiling and spread horizontally.
Mounting the smoke alarm on the ceiling in the center of the room places it closest
to all points in the room. Ceiling mounting is required in ordinary residential
construction.
When mounting an alarm on the ceiling, locate it at a minimum of 50 cm (20”)
from the side wall. (see Figure 1).
When mounting the alarm on the wall, use an inside wall with the top edge of the
alarm at a minimum of 10 cm (4”) and a maximum of 30.5 cm (12”) below the
ceiling. (see Figure 1).
0308-7201-02(21008570B)_En.qxd:_ 2012.2.16 12:10 PM Page
Put smoke alarms at both ends of a bedroom hallway or large room if the hallway
or room is more than 9.1 m (30 feet) long.
Install Smoke Alarms on sloped, peaked or cathedral ceilings at or within 0.9 m (3
ft) of the highest point (measured horizontally). Smoke alarms in rooms with ceil-
ing slopes greater than .3 m in 2.4 m (1 foot in 8 feet) horizontally shall be located
on the high side of the room. A row of detectors shall be spaced and located
within 0.9 m (3 ft) of the peak of the ceiling measured horizontally (see Figure 3).
Smoke Alarms for Minimum Protection
Smoke Alarms for Additional Protection
Heat Alarms for Additional
Protection
FIGURE 2
FIGURE 3
FIGURE 1
0308-7201-02(21008570B)_En.qxd:_ 2012.2.16 12:10 PM Page

Produkspesifikasjoner

Merke: Kidde
Kategori: Røykvarsler
Modell: DAAF 10Y29
Vekt: 121 g
Høyde: 45 mm
Strømkilde: Batteri
Bruksanvisning: Ja
Tilkoblingsteknologi: Trådløs
Diameter: 105 mm
Opprinnelsesland: Frankrike
Pakkevekt: 167 g
Sertifisering: CE, Norme EN 14604, NF
Batterilevetid: 10 år
Detektortype: Optical reflekterende detektor
Lysalarm: Ja
Batteriteknologi: Lithium
Testknapp: Ja
Produktfarge: Hvit
Monteringssett: Ja
Antall støttede batterier: 1
Batterispenning: 3 V
Pakketype: Blister
Driftstemperatur (T-T): 0 - 40 °C
tilbakestillingsknapp: Ja
Skruer inkludert: Ja
Indikator for lavt batterinivå: Ja
Støttede plasseringer/plasseringer som kan benyttes: Horisontal/vertikal
Montasjetype: Flate-montert
Enkel installering: Ja
Lydstyrke på alarm: 85 dB
Interconnectable: Nei