First Alert SC7010B Bruksanvisning

Les nedenfor 📖 manual på norsk for First Alert SC7010B (2 sider) i kategorien Røykvarsler. Denne guiden var nyttig for 2 personer og ble vurdert med 4.5 stjerner i gjennomsnitt av 2 brukere

Side 1/2
Model SC7010B
I
NTRODUCTION
T
hank you for choosing First Alert
®
f
or your Smoke and Carbon
M
onoxide Alarm needs. You have purchased a state-of-the-art Smoke &
Carbon Monoxide Alarm designed to provide you with early warning of a
f
ire or Carbon Monoxide.
K
ey features include:
S
moke & Carbon Monoxide Combination Alarm.
O
ne alarm protects
a
gainst two deadly household threats.
S
pread Spectrum Horn Tone.
L
ower and varying horn frequency
m
akes it easier for elderly with normal age related hearing loss to hear
horn. Sweeps through the 2200 – 3400 Hz range.
Smart Interconnect can be interconnected to BRK Smoke, CO, and
H
eat Alarms. One interconnect wire carries both smoke and CO alarm
s
ignals.
O
ptipath 360 Technology
T
M
p
rovides 360 degrees of direct access to
t
he smoke sensor.
S
ingle Button Test/Silence
e
liminates confusion. Depending on what
mode the alarm is in, pushing the button provides different functions
s
uch as testing the alarm, silencing the alarm, re-testing the alarm when
i
n silence and clearing the Latching features.
T
wo Silence Features.
T
emporarily silence low battery chirp for up to
e
ight hours before replacing low battery or silence an unwanted alarm
for several minutes.
Two Latching Features. Alarm Latch: Easily identifies initiating alarm
e
ven after alarm condition has subsided. Low Battery Latch: Identifies
w
hich unit is in low battery condition.
P
erfect Mount System
i
ncludes a gasketless base for easy installation
and a mounting bracket that keeps the alarm secure over a wide
r
otation range to allow for perfect alignment.
Dust Cover is included to keep the alarm clean during construction.
Easy Installation/Maintenance features include a large opening in
t
he mounting bracket for easy access to wiring. A battery pull tab that
k
eeps the battery fresh until the home is occupied. A Side Load Battery
Drawer allows for easy battery replacement without removing the alarm
f
rom the ceiling or wall.
Improved UV Resistance keeps the alarm from discoloring over time.
©
2008 BRK Brands, Inc. All rights reserved.
D
istributed by BRK Brands, Inc.
3901 Liberty Street Road, Aurora, IL 60504-8122
C
onsumer Affairs: (800) 323-9005 • www.firstalert.com
1
SMOKE & CARBON
MONOXIDE ALARM
A
ll First Alert
®
S
moke Alarms conform to regulatory requirements,
i
ncluding UL217 and are designed to detect particles of combustion.
Smoke particles of varying number and size are produced in all
f
ire
s.
I
onization technology is generally more
sensitive than photoelectric
technology at detecting small particles, which tend to be produced
in greater amounts by flaming fires, which consume combustible
m
aterials rapidly and spread quickly. Sources of these fires may include
paper bur
n
ing in a wastebasket, or a gre
ase fire
in the kitchen.
Photoelectric technology is generally mor
e
sensitive than ionization
technology at detecting large particles, which tend to be produced
i
n gre
ater amounts by smoldering fires, which may smolder for
hours before bursting into flame. Sources of these fires may include
cigarettes burning in couches or bedding.
For maximum pr
otection, use both types of Smoke Alar
ms on each
l
evel and in every bedroom of your home.
USER’S MANUAL
AC Powered Smoke & Carbon Monoxide Alarm
F
eatures:
Two Latching Features
S
mart Interconnect
Optipath 360 Technology
T
M
T
wo Silence Features
A
lkaline Battery Backup
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.
T
his user’s manual contains important information about your Alarm’s
operation. If you ar
e
installing the Alarm for use by others, you must
leave this manual—or a copy of it—with the end user.
ELECTRICAL SHOCK HAZARD. Turn off the power to the area
where the Smoke Alarm is installed before removing it from the
mounting bracket. Failure to turn off the power first may result in
serious electrical shock, injury or death.
This unit will not alert hearing impaired residents.
It is recommended that you install special units which use
devices like flashing strobe lights to alert hearing impaired
residents.
Installation of this unit must confor
m to the electrical codes
in your ar
ea; Ar
ticles 210 and 300.3 (B) of NFPA 70 (NEC),
NFPA 72, NFPA 101; SBC (SBCCI); UBC (ICBO); NBC
(BOCA); OTFDC (CABO), and any other local or building
codes that may apply. Wiring and installation must be
per
formed by a licensed electrician. Failure to follow these
guidelines may result in injur
y or pr
oper
ty damage.
This unit must be powered by a 24-hour, 120V
AC
pure sine
wave 60Hz circuit. Be sure the circuit cannot be turned
off by a switch, dimmer, or ground fault circuit interrupter.
Failur
e to connect this unit to a 24-hour circuit may pre-
vent it from providing constant protection.
This Alarm must have AC or battery power to operate.
If the AC power fails, battery back-up will allow the alarm
to sound for at least 4 minutes. If AC power fails and the
batter
y is weak, protection should last for at least 7 days.
If AC power fails and the battery is dead or missing, the
alarm cannot operate.
Never disconnect the power from an AC powered unit to
stop an unwanted alar
m. Doing so will disable the unit and
r
emove your protection. In the case of a true unwanted
alarm open a window or fan the smoke away from the unit.
The alar
m will r
eset automatically when it r
eturns to normal
operation. Never remove the batteries from a battery
operated unit to stop an unwanted alarm (caused by cooking
smoke, etc.). Instead open a window or fan the smoke away
from the unit. The alarm will reset automatically.
Connect this unit ONLY to other compatible units. See
“How To Install This Smoke Alarm” for details. Do not
connect it to any other type of alarm or auxiliary device.
Connecting anything else to this unit may damage it or
pr
event it fr
om operating pr
operly
.
This Smoke/CO Alarm has a battery drawer which resists
closing unless a battery is installed. This warns you the
unit will not operate under DC power without a batter
y.
Do not stand too close to the unit when the alarm is
sounding. It is loud to wake you in an emer
gency
. Exposur
e
to the horn at close range may harm your hearing.
Do not paint over the unit. Paint may clog the openings to
the sensing chambers and prevent the unit from operating
properly.
The Mounting Bracket:
T
o remove the mounting bracket from the Alarm
base, hold the Alarm base firmly and twist the
mounting bracket counterclockwise. The mounting
b
racket installs onto the junction box. It has a
variety of screw slots to fit most boxes.
The Power Connector:
T
he power connector plugs into a power input block
o
n the Alarm. It supplies the unit with AC power.
The black wire is “hot.”
The white wire is neutral.
The orange wire is used for interconnect.
If you need to remove the power connector, turn
POWER OFF first.
Insert a flat screwdriver blade
b
etween the power connector and the security tab
inside the power input block. Gently pry back the tab
and pull the connector free.
4
5
6
8
9
1
0
7
The Parts of This Unit
1
Mounting Bracket
2
Mounting Slots
3 Locking Pins (break out of
b
racket)
4 Hot (Black) AC Wire
5
Neutral (White) AC Wire
6 Interconnect (Orange) Wire
7 Quick-Connect Power
Connector
8
Turn this way to remove
f
rom bracket
9
Turn this way to attach to
bracket
10 Slide-Out Battery Drawer
HOW TO INSTALL THIS SMOKE/CO ALARM
THE PARTS OF THIS ALARM
This Smoke/CO Alarm is designed to be mounted on any standard wiring junction box up to a 4-inch (10 cm) size, on either the ceiling or wall (if allowed
b
y local codes). Read “Where to Install This Alarm” and “Where This Alarm Should Not Be Installed” before you begin installation.
Tools you will need: • Needle-nose pliers or utility knife Standard flathead screwdriver Wire strippers.
M
ake sure the Alarm is not receiving excessively noisy power. Examples of noisy power could be major appliances on the same circuit, power
f
rom a generator or solar power, light dimmer on the same circuit or mounted near fluorescent lighting. Excessively noisy power may cause
damage to your Alarm.
The basic installation of this Alarm is similar whether you want to
i
nstall one Alarm, or interconnect more than one Alarm. If you are
i
nterconnecting more than one Alarm, you MUST read “Special
Requirements For Interconnected Alarms” below before you begin
i
nstallation.
E
LECTRICAL SHOCK HAZARD. Tu
rn off power to the area where
you will install this unit at the circuit breaker or fuse box before
b
eginning installation. Failure to turn off the power before installa-
t
ion may result in serious electrical shock, injury or death.
1. Remove the mounting bracket
f
rom the base, and attach it to
t
he junction box.
2.
Using wire nuts, connect the
p
ower connector to the
h
ousehold wiring.
3
. Plug the power connector into the back of the Alarm.
4. Activate the battery back-up by removing the “Pull to Activate
Battery Back-Up” tab. Or
, install battery back-up. Battery back-up
c
annot work until you install the battery in the correct position
(Match “+” to “+” and “-” to “-”).
5.
Position the base of the Alarm over the mounting bracket, and turn
t
he Alarm clockwise (right) until the unit is in place. If wall mounted,
a
djust unit so words are level.
6. Check all connections.
Impr
oper wiring of the power connector or the wiring leading to
t
he power connector will cause damage to the Alarm and may
lead to a non-functioning Alar
m
.
ELECTRICAL SHOCK HAZARD. Do not r
estore power until all
Alarms are completely installed. Restoring power before installation
is complete may result in serious electrical shock, injury or death.
7. Make sure the Alarm is receiving AC power. Under normal
operation, the Green power indicator light will shine continuously.
8. If the Green power indicator light does not light,
TURN OFF
POWER TO THE JUNCTION BOX
and recheck all connections.
If all connections are correct and the Green power indicator still
does not light when you restore the power, the unit should be
replaced immediately.
9. Test each Smoke Alarm. Press and hold the Test/Silence button
until the unit alarms.
When testing a series of interconnected
units you must test each unit individually
. Make sure all units
alarm when each one is tested.
If any unit in the series does not alar
m, TURN OFF POWER and
recheck connections. If it does not alarm when you restore power,
r
eplace it immediately
.
FOLLOW THESE INSTALLATION STEPS
S
TA
ND-ALONE ALARM ONLY:
C
onnect the white wire on the power connector to the neutral
wire in the junction box.
Connect the black wire on the power connector to the hot wire
i
n the junction box.
Tuck the orange wire inside the junction box. It is used for
interconnect only.
I
NTERCONNECTED UNITS ONLY
:
S
trip off
about 1/2” (12 mm) of the plastic coating on the orange
wire on the power connector.
Connect the white wire on the power connector to the neutral
w
ire in the junction box.
Connect the black wire on the power connector to the hot wire
in the junction box.
Connect the orange wire on the power connector to the
i
nterconnect wire in the junction box. Repeat for each unit you
a
re
interc
onnecting. Never connect the hot or neutral wire
s in the
junction box to the orange interconnect wire. Never cross hot and
n
eutral wires between Alarms.
STAND-ALONE ALARM ONLY:
I
f you are only installing one Alarm, restore power to the junction
box.
I
NTERCONNECTED UNITS ONLY:
If you are interconnecting multiple Alarms, repeat steps
1-5 for each Alar
m in the series. When you ar
e finished,
r
estore power to the junction box.
Special Requirements For Interconnected Alarms
Failure to meet any of the above requirements could damage
t
he units and cause them to malfunction, removing your
p
rotection.
AC and AC/DC Alarms can be interconnected. Under AC
power, all units will alarm when one senses smoke or CO.
W
hen power is interrupted, only the AC/DC units in the
s
eries will continue to send and receive signals. AC powered
Alarms will not operate.
Interconnected units can provide earlier warning of fire than stand-alone
u
nits, especially if a fire starts in a remote area of the dwelling. If any unit
i
n the series senses smoke, all units will alarm. To determine which Alarm
initiated an alarm, see table:
D
uring an Alarm
:
On Initiating Alarm(s) Red LED(s) flashes (flash) rapidly
On All Other Alarms Red LED is Off
A
fter an Alarm (Latching):
O
n Initiating Alarm(s) Red LED(s) On for 2 seconds/Off for 2 seconds
O
n All Other Alarms Green LED(s) On, Red LED(s) Off
C
ompatible Interc
onnected Units
I
nterc
onnect units within a single family re
sidence only. Otherwise all
households will experience unwanted alarms when you test any unit
i
n the series. Interconnected units will only work if they are wired to
c
ompatible units and all re
quire
ments are
met. This unit is designed to
be compatible with:
BRK Electronics
®
Smoke Alarm Models 9120,
9
120B, SC9120B, 7010, 7010B, 4120, 4120B, 4120SB, 4919, 2002RAC,
1
00S, 5919, 5919TH;
B
RK Electronics
®
H
eat Alarm Models HD6135F,
HD6135FB; BRK Electronics
®
CO Alarm Models CO5120BN,
C
O5120PDBN; Smoke/CO Alarm Model SC6120B, SC7010BV, SC7010B;
a
nd
F
irst Alert
®
S
moke Alarm Models SA4120, SA4120B, SA4121B,
SA4919B, SA100B.
Interconnected units must meet ALL of the following requirements:
A
maximum of 18 compatible units may be interc
onnected
(Maximum of 12 Smoke Alarms).
The same fuse or circuit breaker must power all interconnected
u
nits.
T
he total length of wire
interconnecting the units should be
less than 1000 feet (300 meters). This type of wire is commonly
a
vailable at Hardware and Electrical Supply stores.
All wiring must conform to all local electrical codes and NFPA 70
(NEC). Refer to NFPA 72, NFPA 101, and/or your local building
c
ode for further connection requirements.
5
}
A
}
B
8
7
6
3
11
2
2
3
4 4
5
A. Unswitched 120VAC
60 Hz sour
ce
B
.
T
o additional units; Maximum = 18 total
(Maximum 12 Smoke Alarms)
1. Alarm
2. Ceiling or W
all
3.
Power Connector
4. Wir
e Nut
5. Junction Box
6.
Neutral Wir
e (Wht)
7.
Inter
connect Wir
e
(Orange)
8. Hot Wire (Blk)
2 3 4 5
I
NSTALLATION
WHERE TO INSTALL THIS ALARM
Minimum coverage for Smoke Alarms, as recommended by the
N
ational Fire Protection Association (NFPA), is one Smoke Alarm on
e
very floor, in every sleeping area, and in every bedroom (See
“Regulatory Information For Smoke Alarms” for details on the NFPA
r
ecommendations).
F
or CO Alarms,
t
he National Fire Protection Association (NFPA)
r
ecommends that a CO Alarm should be centrally located outside of
each separate sleeping area in the immediate vicinity of the bedrooms.
F
or added protection, install additional CO Alarms in each separate
b
edroom, and on every level of your home.
N
OTE:
F
or added protection, install an additional Smoke/CO Alarm at
least 15 feet (4.6 meters) away from the furnace or fuel burning heat
source where possible. In smaller homes or in manufactured homes
w
here this distance cannot be maintained, install the Alarm as far away as
possible from the furnace or other fuel burning source. Installing the Alarm
closer than 15 feet (4.6 meters) will not harm the Alarm, but may increase
t
he frequency of unwanted alarms.
I
n general, install combination Smoke and Carbon Monoxide Alarms:
On every level of your home, including finished attics and basements.
Inside every bedroom, especially if people sleep with the door partly
o
r completely closed.
In the hall near every sleeping area. If your home has multiple
sleeping areas, install a unit in each. If a hall is more than 40 feet
(
12 meters) long, install a unit at each end.
At the top of first-to-second floor stairs.
At the bottom of the basement stairs.
For additional coverage, install Alarms in all rooms, halls, and storage
areas, where temperatures normally remain between 40˚ F and 100˚ F
(4˚ C and 38˚ C).
RECOMMENDED PLACEMENT
When installing on the wall, the top edge of Smoke Alarms should
b
e placed between 4 inches (102 mm) and 12 inches (305 mm) from
t
he wall/ceiling line.
When installing on the ceiling, place the alarm as close to the center
as possible.
In either case, install at least 4 inches (102 mm) from where the
w
all and ceiling meet. See “Avoiding Dead Air Spaces” for more
i
nformation.
N
OTE:
F
or any location, make sure
no door or other obstruction could
keep carbon monoxide or smoke from reaching the Alarm.
I
nstalling Smoke/CO Alarms in Mobile Homes
For minimum security install one Smoke/CO Alarm as close to each
s
leeping area as possible. For more security, put one unit in each room.
Many older mobile homes (especially those built before 1978) have little
or no insulation. If your mobile home is not well insulated, or if you ar
e
u
nsure of the amount of insulation, it is important to install units on
inside walls only.
WHERE THIS ALARM SHOULD NOT BE INSTALLED
Do NOT locate this Smoke/CO Alar
m:
In garages, furnace rooms, crawl spaces and unfinished attics.
A
void extremely dusty, dirty or greasy areas.
Where combustion particles are produced. Combustion particles
f
orm when something burn
s. Areas to avoid include poorly ventilated
kitchens, garages, and furnace rooms. Keep units at least 20 feet
(6 meters) from the sources of combustion particles (stove, furnace,
w
ater heater, space heater) if possible. In areas where a 20-foot
(6 meter) distance is not possible – in modular
,
mobile, or smaller
homes, for example – it is recommended the Smoke Alarm be
p
laced as far from these fuel-burning sources as possible. The
placement recommendations are intended to keep these Alarms at
a reasonable distance from a fuel-burning source, and thus reduce
unwanted” alarms. Unwanted alarms can occur if a Smoke Alarm is
placed directly next to a fuel-burning source. Ventilate these areas
as much as possible.
Within 5 feet (1.5 meters) of any cooking appliance. In air streams
n
ear kitchens. Air currents can draw cooking smoke into the smoke
s
ensor and cause unwanted alarms.
In extremely humid areas. This Alarm should be at least 10 feet (3
meters) from a shower, sauna, humidifier, vaporizer, dishwasher,
laundry room, utility room, or other sour
ce of high humidity.
In dir
ect sunlight.
In turbulent air, like near ceiling fans or open windows. Blowing air
may prevent CO or smoke from r
eaching the sensors.
In ar
eas where temperature is colder than 40˚ F (4˚ C) or hotter than
100˚ F (38˚ C). These areas include non-airconditioned crawl spaces,
unfinished attics, uninsulated or poorly insulated ceilings, porches,
and garages.
In insect infested areas. Insects can clog the openings to the sensing
chamber.
Less than 12 inches (305 mm) away from fluorescent lights.
Electrical “noise” can interfere with the sensor.
In “dead air” spaces. See “Avoiding Dead Air Spaces”.
A
VOIDING DEAD AIR SPACES
“Dead air” spaces may prevent smoke from reaching the Smoke/CO
Alarm. To avoid dead air spaces, follow installation recommendations
below
.
On ceilings, install Smoke/CO Alarms as close to the center of the
ceiling as possible. If this is not possible, install the Smoke/CO Alarm
at least 4 inches (102 mm) fr
om the wall or cor
ner.
For wall mounting (if allowed by building codes), the top edge of
Smoke/CO Alarms should be placed between 4 inches (102 mm) and
12 inches (305 mm) fr
om the wall/ceiling line, below typical “dead air”
spaces.
On a peaked, gabled, or cathedral ceiling, install first Smoke/CO
Alarm within 3 feet (0.9 meters) of the peak of the ceiling, measur
ed
horizontally. Additional Smoke/CO Alarms may be required depending
on the length, angle, etc. of the ceiling's slope. Refer to NFP
A 72 for
details on requirements for sloped or peaked ceilings.
SUGGESTED AREAS FOR INSTALLING 
SMOKE ALARMS, CO ALARMS, AND COMBO UNITS
SMOKE ALARM WITH 
S
ILENCE FEATURE
CO ALARMS
B
OTH, OR COMBINATION 
S
MOKE/CO ALARMS
S
MOKE ALARMS
KEY:
S
uggested locations are based on
NFPA recommendations (NFPA 72 
for Smoke Alarms and NFPA 720 for
Carbon Monoxide Alarms). Always 
refer to national and local codes 
b
efore beginning any installation.
In new construction AC and AC/DC smoke alarms MUST
be interconnected to meet NFPA recommendations.
LOCKING FEATURES
T
he locking features are designed to discourage unauthorized removal of the batteries or Alarm. It is not necessary to activate the locks in
single-family households where unauthorized battery or Alarm removal is not a concern.
T
hese Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the Alarm
to the mounting bracket. You can choose to use either feature independently, or use them both.
Tools you will need: Needle-nose pliers • Standard Flathead screwdriver.
B
oth locking features use locking pins, which are molded into the mounting bracket. Using needle-nose pliers, remove
one or both pins from the mounting bracket, depending on how many locking features you want to use.
To permanently remove either lock, insert a flathead screwdriver between the locking pin and the lock, and pry the pin out of the lock.
TO LOCK THE BATTERY COMPARTMENT
Do not lock the battery compartment until you have installed the
battery and tested the battery back-up.
1
. Push and hold Test/Silence button until the alarm sounds.
If the unit does not alarm during testing, DO NOT lock the battery
compartment! Install a new battery and test again. If the Alarm still
d
oes not alarm, replace it immediately.
2. Using needle-nose pliers, detach one locking pin from the mounting
b
racket.
3
. Push the locking pin through the hole near the battery drawer on
t
he back of the Alarm.
T
O UNLOCK THE BATTERY COMPARTMENT
O
nce the Alarm is installed, you must disconnect it from the AC power
before unlocking the battery compartment.
ELECTRICAL SHOCK HAZARD. Turn off the power to the area where
the Alarm is installed before removing it from the mounting bracket.
F
ailure to turn off the power first may result in serious electrical
shock, injury or death.
A
lways discharge the branch circuit before servicing an AC or AC/DC
Alarm. First, turn off the AC power at the circuit breaker or fuse box.
Next, remove the battery from Alarms with battery back-up. Finally,
p
ress and hold the Test/Silence button for 5-10 seconds to discharge
the branch circuit.
1. Remove the Alarm from the mounting bracket.
I
f the unit is locked to the bracket, see the
section “To Unlock the Mounting Bracket.”
2. Disconnect the power connector by gently
prying it away from the back of the Alarm.
3. Insert a flathead screwdriver under the head
o
f the locking pin, and gently pry it out of the
battery compartment lock. (If you plan to
relock the battery compartment, save the
l
ocking pin.)
4
. To relock the battery compartment, close the battery door and
r
einsert locking pin in lock.
5
. Reconnect the power connector to the back of the Alarm, reattach
t
he Smoke Alarm to the mounting bracket, and restore the power.
W
hen replacing the batteries, always test the Alarm before relocking
t
he battery compartment.
TO UNLOCK THE MOUNTING BRACKET
ELECTRICAL SHOCK HAZARD. Turn off the power to the area where
t
he Alarm is installed before removing it from the mounting bracket.
F
ailure to turn off the power first may result in serious electrical
shock, injury or death.
A
lways discharg
e the branch circuit before servicing an AC or AC/DC
Alarm. First, turn off the AC power at the circuit breaker or fuse box.
N
ext, remove the battery from Alarms with battery back-up. Finally,
p
ress and hold the Test/Silence button for 5-10 seconds to discharge
the branch circuit.
1. Insert a flathead screwdriver between the
m
ounting bracket pin and the mounting
b
racket.
2. Pry the Alarm away from the bracket by
t
ur
n
ing both the screwdriver and the Alarm
c
ounterc
lockwise (left) at the same time.
TO LOCK THE MOUNTING BRACKET
1
. Using needle-nose pliers, detach one locking pin from mounting
bracket.
2
. I
nsert the locking pin into the lock located
o
pposite from the battery drawer as
shown in the diagram.
3
. W
hen you attach the Alarm to the mounting bracket, the locking
p
in’s head will fit into a notch on the bracket.
WHAT YOU WILL SEE AND HEAR WITH THIS ALARM
Under Normal Operations
H
orn:
S
ilent
P
ower/Smoke LED:
C
onstant Green
C
O LED:
O
ff
When You Test the Alarm
H
orn
:
3
beeps, pause, 3 beeps
Power/Smoke LED: Flashes Red in sync with the hor
n patter
n
C
O LED:
O
ff, followed by
Horn: 4 beeps, pause, 4 beeps
P
ower/Smoke LED:
O
ff
CO LED: Flashes Red in sync with the horn pattern
If Battery Becomes Low or is Missing
H
orn
:
c
hirps once a minute
Power/Smoke LED: Flashes Green On for 2 seconds/Off for
2
seconds. Low Battery Latch is now engaged.
CO LED: Off
If Alarm is Not Operating Properly
H
orn:
T
hree rapid chirps every minute
Power/Smoke LED: Flashes approximately once a minute
C
O LED:
O
ff
Alar
m Levels of CO are Detected
Horn:
4 beeps, pause, 4 beeps*
Power/Smoke LED: Off
CO LED: During Alarm: Flashes Red in sync with the horn pattern.
After Alarm: Flashes Red On for 2 seconds/Off for 2
seconds. CO Alarm Latch is now engaged.
*NOTE: If unit goes into CO alarm, the regular 4 beeps-brief pause
cycle will repeat for fifteen minutes. After fifteen minutes, the pause
will incr
ease to one minute.
Smoke is Detected
Horn: 3 beeps, pause, 3 beeps
Power/Smoke LED: During Alarm: Flashes Red in sync with the
horn pattern. After Alarm: Flashes Red On for 2 seconds/Off
for 2 seconds. Smoke Alarm Latch is now engaged.
CO LED: Off
Smoke Alarm is Silenced
Horn: Off
Power/Smoke LED: Flashes
Red
CO LED: Off
CO Alarm is Silenced
Horn: Off
Power/Smoke LED: Off
CO LED: Flashes Red
WEEKL
Y TESTING
NEVER use an open flame of any kind to test this unit. You
might accidentally damage or set fir
e to the unit or to your
home. The built-in test switch accurately tests the unit’
s
operation as required by Underwriters Laboratories, Inc. (UL).
NEVER use vehicle exhaust! Exhaust may cause per
manent
damage and voids your warranty.
If the Alar
m ever fails to test pr
operly
, r
eplace it immediately.
Pr
oducts under warranty may be returned to the manufacturer
for replacement. See “Limited Warranty” at the end of this
manual.
It is important to test this unit every week to make
sur
e it is working pr
operly. Using the test button is
the recommended way to test this Smoke/CO Alarm.
You can test this Smoke/CO Alarm by pressing and
holding the Test/Silence button on the Alarm cover.
During testing, you will see and hear the following
sequence:
The Horn will sound 3 beeps, pause, 3 beeps. The Power/Smoke
LED flashes Red and the CO LED will be Of
f.
Next the
Horn will sound 4 beeps, pause, 4 beeps. The Power/
Smoke LED
will be Off and the CO LED flashes Red.
If the unit does not alarm, make sure the batteries are correctly
installed, and test again. If the unit still does not alarm, replace it
immediately
.
2
1
6
REGULAR MAINTENANCE
Use only the replacement batteries listed below. The unit may not
o
perate properly with other batteries. Never use r
echargeable
b
atteries since they may not provide a constant charge.
This unit has been designed to be as maintenance-free as possible, but
t
here are a few simple things you must do to keep it working properly:
Test it at least once a week.
C
lean the Smoke/CO Alarm at least once a month; gently vacuum
the outside of the Smoke/CO Alarm using your household vacuum’
s
s
oft brush attachment. Test the Smoke/CO Alarm. Never use water,
cleaners or solvents since they may damage the unit.
If the Smoke/CO Alarm becomes contaminated by excessive dirt,
dust and/or grime, and cannot be cleaned to avoid unwanted
alarms, r
eplace the unit immediately
.
Relocate the unit if it sounds frequent unwanted alarms. See “Where
T
his Alarm Should Not Be Installed” for details.
When the battery back-up becomes weak, the Alarm will “chirp”
a
bout once a minute (the low battery warning). This warning should
last 7 days, but you should r
eplace the battery immediately to
continue your protection. The Low Battery Latch feature will be
e
ngaged. The Gre
en Power/Smoke LED will flash On for 2 seconds/
Off for 2 seconds.
Choosing a replacement battery:
Your Smoke/CO Alarm requires two “AA” Energizer E91 batteries.
These batteries ar
e available at many local retail stores.
Actual battery service life depends on the Alarm and the envir
onment
in which it is installed. All the batteries specified above are acceptable
replacement batteries for this unit. Regardless of the manufacturer’s
suggested battery life,
you MUST replace the battery immediately
once the unit starts “chirping” (the “low battery warning”).
To replace the batteries (without removing Alarm from the ceiling
or wall):
1. Open the battery compartment.
2. Press tabs A and B as shown in the
diagram and remove each battery.
3. Insert the new batteries, making sure
they snap completely into the battery
compartment. Match the terminals on
the ends of the batteries with the
terminals on the unit.
4. Close the battery compartment, and
then test the unit by pressing the
Test/Silence button.
A
B
T
ype of Alar
m
Carbon Monoxide (CO)
What Y
ou See and Hear
Horn:
4 beeps, pause, 4 beeps
Power/Smoke LED: Off
CO LED: Flashes Red
Smoke
Horn: 3 beeps, pause, 3 beeps
Power/Smoke LED: Flashes Red
CO LED: Off
IF YOUR SMOKE/CO ALARM SOUNDS
WHAT TO DO FIRST–
IDENTIFY THE TYPE OF ALARM SIGNAL
Continued...
Printed in Mexico
M08-0182-002
K1
08/08
L
ISTED TO
UL 217 and
U
L 2034
STANDARDS
ABOUT SMOKE ALARMS
B
attery (DC) operated Smoke Alarms:
P
rovide protection even when
e
lectricity fails, provided the batteries are fresh and correctly installed.
U
nits are easy to install, and do not require professional installation.
H
owever, they do not provide interconnected functionality.
A
C powered Smoke Alarms:
C
an be interconnected so if one unit
s
enses smoke, all units alarm. They do not operate if electricity fails.
A
C with battery (DC) back-up:
w
ill operate if electricity fails, provided
t
he batteries are fresh and correctly installed. AC and AC/DC units must
b
e installed by a qualified electrician.
W
ireless Interconnected Alarms:
O
ffer the same interconnected
functionality as with hardwired alarms, without wires. Units are easy
t
o install and do not require professional installation. They provide
p
ro
tection even when electricity fails, provided the batteries are fresh
and correctly installed.
Smoke/CO Alarms for Solar or Wind Energy users and battery
b
ackup power systems:
A
C powered Smoke/CO Alarms should only
b
e operated with true or pure sine wave inverters. Operating this Alarm
with most battery-powered UPS (uninterruptible power supply) products
o
r square wave or “quasi sine wave” inverters
w
ill damage the Alarm
.
I
f you are not sure about your inverter or UPS type, please consult with
the manufacturer to verify.
Smoke Alar
ms for the hearing impair
e
d:
Special purpose Smoke
A
larms should be installed for the hearing impaired. They include a
v
isual alarm and an audible alarm horn, and meet the requirements of
the Americans With Disabilities Act. Can be inter
connected so if one
u
nit senses smoke, all units alarm.
S
moke alarms are not to be used with detector guards
u
nless the
c
ombination has been evaluated and found suitable for that purpose.
All these Smoke Alarms are designed to provide early warning of fires if
located, installed and cared for as described in the user’s manual, and if
s
moke reaches the Alarm. If you are unsure which type of Smoke Alarm
to install, refer the National Fire Protection Association (NFPA) Standard
72 (National Fir
e Alarm Code) and NFP
A 101 (Life Safety Code).
N
ational Fire Protection Association, One Batterymarch Park, Quincy, MA
02269-9101. Local building codes may also require specific units in new
construction or in dif
fer
ent ar
eas of the home.
SPECIAL COMPLIANCE CONSIDERA
TIONS
T
his unit alone is not a suitable substitute for complete fire
detection systems in places housing many people—like apartment
b
uildings, condominiums, hotels, motels, dormitories, hospitals,
l
ong-term
health care facilities, nursing homes, day care facilities,
or group homes of any kind—even if they were once single-family
h
omes. It is not a suitable substitute for complete fire detection
s
ystems in ware
houses, industrial facilities, commerc
ial buildings,
and special-purpose non-residential buildings which require special
f
ire detection and alarm systems. Depending on the building codes
i
n your area, this unit may be used to provide additional protection
in these facilities.
T
he following information applies to all five types of buildings listed
below:
In new construction, most building codes require the use of AC or AC/DC
powered Smoke Alarms only. AC, AC/DC, DC or Wireless DC powered
S
moke Alarms can be used in existing construction as specified by
local building codes. Refer to NFPA 72 (National Fire Alarm Code) and
NFPA 101 (Life Safety Code), local building codes, or consult your Fire
Department for detailed fire protection requirements in buildings not
defined as “households.”
1. Single-Family Residence:
Single family home, townhouse. It is recommended this unit be installed
on every level of the home, in every bedroom, and in each bedroom
hallway.
2. Multi-Family or Mixed Occupant Residence:
Apartment building, condominium. This unit is suitable for use in
individual apartments or condos, provided a primary fire detection
system already exists to meet fire detection requirements in common
areas like lobbies, hallways, or porches. Using this unit in common
areas may not provide sufficient warning to all residents or meet local
fire pr
otection ordinances/regulations.
3. Institutions:
Hospitals, day care facilities, long-term health care facilities. This unit is
suitable for use in individual patient sleeping/resident r
ooms, provided
a primary fir
e detection system already exists to meet fire detection
r
equirements in common areas like lobbies, hallways, or porches. Using
this unit in common areas may not provide sufficient warning to all
residents or meet local fire protection ordinances/regulations.
4. Hotels and Motels:
Also boarding houses and dormitories. This unit is suitable for use inside
individual sleeping/resident rooms, provided a primary fire detection
system already exists to meet fire detection requirements in common
ar
eas like lobbies, hallways, or porches. Using this unit in common areas
may not provide sufficient warning to all residents or meet local fire
pr
otection or
dinances/r
egulations.
5. Warehouses/Commercial Buildings:
DO NOT use this Smoke/CO Alarm in war
ehouses, industrial or
commercial buildings, special-purpose non-residential buildings, RVs,
boats, or airplanes. This Smoke/CO Alarm is specifically designed
for residential use, and may not provide adequate protection in non-
residential applications.
T
his Smoke/CO Alarm is intended for residential use. It is not intended
f
or use in industrial applications where Occupational Safety and Health
Administration (OSHA) requirements for Carbon Monoxide Alarms must
b
e met. The Smoke Alarm portion of this device is not intended to alert
h
earing impaired residents. Special purpose Smoke Alarms should be
installed for hearing impaired residents (CO Alarms are not yet available
f
or the hearing impaired).
S
moke/CO Alarms may not waken all individuals.
P
ractice the
e
scape plan at least twice a year, making sure that everyone is involved
from kids to grandparents. Allow children to master fire escape
p
lanning and practice before holding a fire drill at night when they are
s
leeping. If children or others do not readily waken to the sound of the
Smoke/CO Alarm, or if there are infants or family members with mobility
l
imitations, make sure that someone is assigned to assist them in fire
d
rill and in the event of an emergency. It is recommended that you hold
a fire drill while family members are sleeping in order to determine their
r
esponse to the sound of the Smoke/CO Alarm while sleeping and
t
o determine whether they may need assistance in the event of an
emergency.
Smoke/CO Alarms cannot work without power. Battery operated
u
nits cannot work if the batteries are missing, disconnected or dead, if
t
he wrong type of batteries are used, or if the batteries are not installed
correctly. AC units cannot work if the AC power is cut off for any reason
(
open fuse or circuit breaker, failure along a power line or at a power
s
tation, electrical fire that burns the electrical wires, etc.). If you are
concerned about the limitations of battery or AC power, install both
t
ypes of units.
T
his Smoke/CO Alarm will not sense smoke or CO that does not
r
each the sensors.
I
t will only sense smoke or CO at the sensor. Smoke
or CO may be present in other areas. Doors or other obstructions may
a
ffect the rate at which CO or smoke reaches the sensors. If bedroom
d
oors are usually closed at night, we recommend you install an alarm
device (Combination CO and Smoke Alarm, or separate CO Alarms and
S
moke Alarms) in each bedroom and in the hallway between them.
This Smoke/CO Alarm may not sense smoke or CO on another
level of the home.
Example: This alarm device, installed on the second
f
loor, may not sense smoke or CO in the basement. For this reason,
one alarm device may not give adequate early warning. Recommended
minimum protection is one alarm device in every sleeping area, every
b
edroom, and on every level of your home. Some experts recommend
battery powered Smoke and CO Alarms be used in conjunction with
interconnected AC powered Smoke Alarms. For details, see “About
S
moke Alarms” for details.
S
moke/CO Alarms may not be heard.
T
he alarm horn loudness
meets or exceeds current UL standards of 85 dB at 10 feet (3 meters).
However, if the Smoke/CO Alarm is installed outside the bedroom, it
m
ay not wake up a sound sleeper or one who has recently used drugs
or has been drinking alcoholic beverages. This is especially true if the
door is closed or only partly open. Even persons who are awake may
n
ot hear the alarm horn if the sound is blocked by distance or closed
doors. Noise from traffic, stereo, radio, television, air conditioner, or
other appliances may also prevent alert persons from hearing the alarm
h
orn. This Smoke/CO Alarm is not intended for people who are hearing
impaired.
The Alarm may not have time to alarm before the fire itself causes
damage, injury, or death, since smoke from some fires may not
r
each the unit immediately. Examples of this include persons
smoking in bed, children playing with matches, or fires caused by
violent explosions resulting from escaping gas.
This Smoke/CO Alarm is not a substitute for life insurance. Though
t
his Smoke/CO Alarm warns against increasing CO levels or the presence
o
f smoke, BRK Brands, Inc. does not warrant or imply in any way that
they will protect lives. Homeowners and renters must still insure their lives.
T
his Smoke/CO Alarm has a limited life.
A
lthough this Smoke/CO
A
larm and all of its parts have passed many stringent tests and are
designed to be as reliable as possible, any of these parts could fail at
a
ny time. Therefore, you must test this device weekly. The unit should
b
e replaced immediately if it is not operating properly.
This Smoke/CO Alarm is not foolproof. Like all other electronic
d
evices, this Smoke/CO Alarm has limitations. It can only detect smoke
or CO that reaches the sensors. It may not give early warning of the
s
ource of smoke or CO is in a remote part of the home, away from the
a
larm device.
7 8 9
POTENTIAL SOURCES OF CO IN THE HOME
Fuel-burning appliances like: portable heater, gas or wood burning
fir
eplace, gas kitchen range or cooktop, gas clothes dryer.
Damaged or insufficient venting: corroded or disconnected water
heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger,
blocked or clogged chimney opening.
Improper use of appliance/device: operating a barbecue grill or vehicle
in an enclosed ar
ea (like a garage or screened porch).
T
ransient CO Problems:
“transient” or on-again-of
f-again CO problems
can be caused by outdoor conditions and other special circumstances.
The following conditions can result in transient CO situations:
1.
Excessive spillage or r
everse venting of fuel appliances caused by
outdoor conditions such as:
Wind direction and/or velocity, including high, gusty winds.
Heavy air in the vent pipes (cold/humid air with extended periods
between cycles).
Negative pressure differential resulting from the use of exhaust fans.
Several appliances running at the same time competing for limited
fr
esh air
.
Vent pipe connections vibrating loose from clothes dryers,
furnaces, or water heaters.
Obstructions in or unconventional vent pipe designs which can
amplify the above situations.
2. Extended operation of unvented fuel burning devices (range, oven,
fir
eplace).
3.
T
emperatur
e inversions, which can trap exhaust close to the gr
ound.
4. Car idling in an open or closed attached garage, or near a home.
These conditions are dangerous because they can trap exhaust in your
home. Since these conditions can come and go, they are also hard to
recreate during a CO investigation.
H
OW CAN I PROTECT MY FAMILY FROM
CO POISONING?
A
CO Alarm is an excellent means of protection. It monitors the air and
s
ounds a loud alarm before Carbon Monoxide levels become threatening
for average, healthy adults.
A
CO Alarm is not a substitute for proper maintenance of home
appliances.
To help prevent CO problems and reduce the risk of CO poisoning:
Clean chimneys and flues yearly. Keep them free of debris, leaves,
a
nd nests for proper air flow. Also, have a professional check for
rust and corrosion, cracks, or separations. These conditions can
prevent proper air movement and cause backdrafting. Never
cap” or cover a chimney in any way that would block air flow.
Test and maintain all fuel-burning equipment annually. Many local
g
as or oil companies and HVAC companies offer appliance
inspections for a nominal fee.
Make regular visual inspections of all fuel-burning appliances.
C
heck appliances for excessive rust and scaling. Also check the
flame on the burner and pilot lights. The flame should be blue.
A
yellow flame means fuel is not being burned completely and CO
m
ay be present. Keep the blower door on the furnace closed.
Use vents or fans when they are available on all fuel-burning
a
ppliances. Make sure appliances are vented to the outside. Do
n
ot grill or barbecue indoors, or in garages or on screen porches.
Check for exhaust backflow from CO sources. Check the draft
h
ood on an operating furnace for a backdraft. Look for cracks on
furnace heat exchangers.
Check the house or garage on the other side of shared wall.
Keep windows and doors open slightly. If you suspect that CO
i
s escaping into your home, open a window or a door. Opening
windows and doors can significantly decrease CO levels.
In addition, familiarize yourself with all enclosed materials. Read
t
his manual in its entirety, and make sure you understand what to
do if your CO Alarm sounds.
W
HAT YOU NEED TO KNOW ABOUT CO
W
HAT IS CO?
C
O is an invisible, odorless, tasteless gas produced when fossil fuels
do not burn completely, or are exposed to heat (usually fire). Electrical
a
ppliances typically do not produce CO.
T
hese fuels include:
W
ood, coal, charcoal, oil, natural gas, gasoline,
k
erosene, and propane.
C
ommon appliances are often sources of CO. If they are not properly
m
aintained, are improperly ventilated, or malfunction, CO levels can rise
quickly. CO is a real danger now that homes are more energy efficient.
Air-tight” homes with added insulation, sealed windows, and other
w
eatherproofing can “trap” CO inside.
S
YMPTOMS OF CO POISONING
T
hese symptoms are related to CO POISONING and should be
discussed with ALL household members.
Mild Exposure: Slight headache, nausea, vomiting, fatigue (“flu-like”
s
ymptoms).
M
edium Exposure:
T
hrobbing headache, drowsiness, confusion, fast
heart rate.
Extreme Exposure: Convulsions, unconsciousness, heart and lung
f
ailure. Exposure to Carbon Monoxide can cause brain damage, death.
This CO Alarm measures exposure to CO over time. It alarms if CO
l
evels are extremely high in a short period of time, or if CO levels reach
a
certain minimum over a long period of time. The CO Alarm generally
sounds an alarm befor
e
the onset of symptoms in average, healthy
a
dults. Why is this important? Because you need to be warned of a
p
otential CO pro
blem while you can still re
act in time. In many re
ported
cases of CO exposure, victims may be aware that they are not feeling
w
ell, but become disoriented and can no longer react well enough to
e
xit the building or get help. Also, young childre
n and pets may be the
first affected. The average healthy adult might not feel any symptoms
w
hen the CO Alarm sounds. However, people with cardiac or respiratory
p
roblems, infants, unborn babies, pregnant mothers, or elderly people
can be mor
e quickly and sever
e
ly aff
ected by CO. If you experience
e
ven mild symptoms of CO poisoning, consult your doctor immediately!
FINDING THE SOURCE OF CO AFTER AN ALARM
C
arbon monoxide is an odorless, invisible gas, which often makes it
d
iff
icult to locate the sourc
e of CO after an alarm. These are
a few of
the factors that can make it dif
ficult to locate sour
c
es of CO:
House well ventilated befor
e the investigator arrives.
Pr
oblem caused by “backdrafting.”
Tr
ansient CO problem caused by special cir
cumstances.
B
ecause CO may dissipate by the time an investigator arrives, it may
be difficult to locate the source of CO.
BRK Brands, Inc. shall not be
obligated to pay for any carbon monoxide investigation or ser
vice
c
all.
10 11 12
IF THE SMOKE ALARM SOUNDS
R
ESPONDING TO AN ALARM
If the unit alarms and you are not testing the unit, it is warning
you of a potentially dangerous situation that requires your
i
mmediate attention. NEVER ignore any alarm. Ignoring the
a
larm may result in injury or death.
Never remove the batteries from a battery operated Smoke/CO
Alarm to stop an unwanted alarm (caused by cooking smoke,
e
tc.). Removing batteries disables the alarm
so it cannot sense
smoke, and removes your protection. Instead open a window or
fan the smoke away from the unit. The alarm will reset automati-
c
ally.
If the unit alarms get everyone out of the house immediately.
W
HAT
TO DO IN CASE OF FIRE
D
on’t
panic; stay calm. Follow your family escape plan.
G
et out of the house as quickly as possible. Don’t
stop to get
d
ressed or collect anything.
Feel doors with the back of your hand before opening them.
I
f a door is cool, open it slowly.
Don’t open a hot door. Keep doors
and windows closed, unless you must escape through them.
Cover your nose and mouth with a cloth (preferably damp).
T
ake short, shallow breaths.
Meet at your planned meeting place outside your home,
and do a head count to make sur
e everybody got out safely
.
Call the Fir
e Department as soon as possible fr
om outside.
G
ive your address, then your name.
Never go back inside a burning building for any reason.
Contact your Fire Department for ideas on making your home safer.
Alarms have various limitations. See "General Limitations of
S
moke/CO Alarms" for details.
LATCHING FEATURES
Alarm Latch is activated after an Alarm is exposed to alarm levels of
s
moke or carbon monoxide. This feature will only work with AC power.
After smoke or CO levels drop below alarm levels, the “Smoke/Power”
or “CO” Red LED will begin to flash once every few seconds. It will
c
ontinue to flash or “latch” until you clear it by testing the alarm.
This feature helps emergency responders, investigators, or service
t
echnicians identify which unit(s) in your home were exposed to alarm
l
evels of smoke or carbon monoxide. This can help investigators
pinpoint the source of smoke or CO.
I
nterconnected Alarms.
L
atching Alarm Indicator shows which Alarm(s)
in the series were exposed to alarm levels of smoke or carbon monoxide.
The Latching Alarm Indicator stays ON until you clear it, so it can alert
you to an alarm that occurred while you were away from home, even
t
hough smoke or CO present in the air has dropped below alarm levels.
Low Battery Latch is activated when the Alarm is in the "low battery
c
ondition". When this occurs, the
S
moke/Power
L
ED flashes Green On
f
or 2 seconds/Off for 2 seconds. This feature is designed to help you
identify which Alarm needs to have the battery replaced. Although, the
A
larm will sound the low battery chirp approximately once every minute,
s
ometimes during the initial stages of "low battery", the Alarm will chirp
in greater intervals than one minute, sometimes up to several hours, until
t
he battery reaches a steady low battery level. This innovative feature
e
liminates the frustration of waiting for and/or identifying which unit is
chirping.
“SMART INTERCONNECT” FEATURE
This Alarm includes "Smart Interconnect" which enables the Alarm to be
interconnected with other First Alert
®
and BRK Smoke, Heat, and "Smart
I
nterconnect" CO Alarms. When smoke is detected, all Alarms will sound
the smoke horn pattern. When CO is detected, "Smart Interconnect"
Alarms will sound the CO horn pattern. Alarms that do not have the
"
Smart Interconnect" feature will remain silent during a CO alarm.
USING THE SILENCE FEATURES
Never r
e
move the batteries to quiet an unwanted alarm
. Removing
the batteries disables the alar
m and removes your protection.
The Silence Featur
e is intended to temporarily silence the hor
n while
y
ou identify and correct the problem. Do not use the Silence Feature in
emergency situations. It will not correct a CO problem or extinguish a
fire.
The Silence Feature can temporarily quiet an unwanted alarm for several
m
inutes. You can silence this Smoke/CO Alarm by pressing the
Test/Silence button on the alarm cover for at least 3-5 seconds.
A
fter the Test/Silence button is released, the Red LED blinks during the
silence mode.
SILENCING THE LOW BATTERY WARNING
This Silence Feature can temporarily quiet the low battery warning
“chirp” for up to 8 hours if AC power is present. Press the Test/Silence
button on the Alarm cover until you hear the acknowledge “chirp”.
Once the low battery warning “chirp” silence feature is activated, the
unit continues to flash the green light once a minute for 8 hours. After
8 hours, the low battery “chirp” will r
esume. The Alarm will continue
to operate as long as AC power is supplied. However,
replace the
batteries as soon as possible, to maintain protection in event of a
power outage.
T
o deactivate this feature:
Pr
ess the Test/Silence button again.
The unit will go into Test Mode and the low battery warning will resume
(LED flashes and unit sounds “chirp” once a minute).
To silence Alarms in an interconnected series:
To silence an interconnected series of Smoke/CO Alarms, you must
press the Test/Silence button on the initiating alarm (The unit with the
flashing red light; the red light will be off on all other Alarms.). If you
press the Test/Silence on any other Alarm, it will only silence that unit,
not the whole interconnected series.
When the Smoke Alarm is
Silenced
When the CO Alarm is
Silenced
The Smoke Alarm will remain
silent for up to 15 minutes, then
return to normal operation.
If the smoke has not cleared–or
continues to increase–the device
will go back into alarm.
The CO alarm will remain silent
for up to 4 minutes.
After 4 minutes, if CO levels
remain potentially dangerous the
horn will start sounding again.
R
EGULATORY INFORMATION FOR
S
MOKE/CO ALARMS
REGULATORY INFORMATION FOR CO ALARMS
W
HAT LEVELS OF CO CAUSE AN ALARM?
U
nderwriters Laboratories Inc. Standard UL2034 requires residential CO
A
larms to sound when exposed to levels of CO and exposure times as
described below. They are measured in parts per million (ppm) of CO
o
ver time (in minutes).
U
L2034 Required Alarm Points*:
If the alarm is exposed to 400 ppm of CO, IT MUST ALARM
BETWEEN 4 and 15 MINUTES.
I
f the alarm is exposed to 150 ppm of CO, IT MUST ALARM
BETWEEN 10 and 50 MINUTES.
If the alarm is exposed to 70 ppm of CO, IT MUST ALARM
BETWEEN 60 and 240 MINUTES.
* A
pproximately 10% COHb exposure at levels of 10% to 95% Relative
Humidity (RH).
T
he unit is designed not to alarm when exposed to a constant level
of 30 ppm for 30 days.
C
O Alarms are designed to alarm before there is an immediate life
threat. Since you cannot see or smell CO, never assume it’s not present.
An exposure to 100 ppm of CO for 20 minutes may not affect
average, healthy adults, but after 4 hours the same level may cause
h
eadaches.
An exposure to 400 ppm of CO may cause headaches in average,
h
ealthy adults after 35 minutes, but can cause death after 2 hours.
S
tandards:
U
nderwriters Laboratories Inc. Single and Multiple Station
c
arbon monoxide alarms UL2034.
A
ccord
ing to Underwriters Laboratories Inc. UL2034, Section 1-1.2:
“Carbon monoxide alarms covered by these requirements are intended
t
o respond to the presence of carbon monoxide from sources such as,
b
ut not limited to, exhaust fro
m intern
al-combustion engines, abnormal
operation of fuel-fired appliances, and fireplaces. CO Alarms are intended
t
o alarm at carbon monoxide levels below those that could cause a loss
o
f ability to react to the dangers of Carbon Monoxide exposure.” This CO
Alarm monitors the air at the Alarm, and is designed to alarm befor
e CO
l
evels become life threatening. This allows you precious time to leave
t
he house and corre
ct the pro
blem. This is only possible if Alarms are
located, installed, and maintained as described in this manual.
Gas Detection at Typical Temperature and Humidity Ranges: The
CO Alarm is not formulated to detect CO levels below 30 ppm typically.
U
L tested for false alarm re
sistance to Methane (500 ppm), Butane (300
ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopr
o
pyl Alcohol
(200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and
v
apor concentrations in parts per million.
Audible Alar
m:
85 dB minimum at 10 feet (3 meters).
REGULATORY INFORMATION FOR SMOKE ALARMS
RECOMMENDED LOCATIONS FOR SMOKE ALARMS
I
nstalling Smoke Alarms in Single-Family Residences
The National Fire Protection Association (NFPA), recommends one Smoke
A
larm on every floor,
in every sleeping area, and in every bedr
oom.
In new construction, the Smoke Alarms must be AC power
e
d and
interconnected. See “Agency Placement Recommendations” for details.
For additional coverage, it is recommended that you install a Smoke
Alarm in all rooms, halls, storage areas, finished attics, and basements,
where temperatures normally remain between 40˚ F (4˚ C) and 100˚ F
(38˚ C). Make sure no door or other obstruction could keep smoke
from reaching the Smoke Alarms.
More specifically, install Smoke Alarms:
On every level of your home, including finished attics and basements.
Inside every bedroom, especially if people sleep with the door partly
or completely closed.
In the hall near every sleeping area. If your home has multiple
sleeping areas, install a unit in each. If a hall is more than 40 feet
long (12 meters), install a unit at each end.
At the top of the first-to-second floor stairway, and at the bottom
of the basement stairway.
Specific requirements for Smoke Alarm installation vary from state to
state and fr
om r
egion to region. Check with your local Fire Department
for current requirements in your area.
It is recommended AC or AC/DC
units be interconnected for added protection.
INSTALLING SMOKE ALARMS IN MOBILE HOMES
For minimum security install one Smoke Alarm as close to each
sleeping ar
ea as possible. For more security, put one unit in each room.
Many older mobile homes (especially those built before 1978) have little
or no insulation. If your mobile home is not well insulated, or if you are
unsur
e of the amount of insulation, it is important to install units on
inside walls only. Smoke Alarms should be installed where temperatures
normally r
emain between 40˚ F (4˚ C) and 100˚ F (38˚ C).
A
GENCY PLACEMENT RECOMMENDATIONS
S
tandards:
U
nderwriters Laboratories Inc. Single and Multiple Station
S
moke Alarms 217.
N
FPA 72 (National Fire Code) Chapter 11
For your information, the National Fire Protection Association's
Standard 72, reads as follows:”
11.5.1 One- and Two-Family Dwelling Units.”
“11.5.1.1 Smoke Detection.
Where required by applicable laws, codes,
o
r standards for the specified occupancy, approved single- and multiple-
s
tation Smoke Alarms shall be installed as follows: (1) In all sleeping
rooms Exception: Smoke Alarms shall not be required in sleeping rooms
i
n existing one- and two-family dwelling units. (2) Outside of each
s
eparate sleeping area, in immediate vicinity of the sleeping rooms.
(3) On each level of the dwelling unit, including basements. Exception:
I
n existing one- and two family dwelling units, approved Smoke Alarms
p
owered by batteries are permitted.”
“A.11.8.3 Are More Smoke Alarms Desirable?
T
he required number of Smoke Alarms might not provide reliable early
warning protection for those areas separated by a door from the areas
protected by the required Smoke Alarms. For this reason, it is recom-
m
ended that the householder consider the use of additional Smoke
Alarms for those areas for increased protection. The additional areas
include the basement, bedrooms, dining room, furnace room, utility
r
oom, and hallways not protected by the required Smoke Alarms. The
installation of Smoke Alarms in kitchens, unfinished attics, or garages is
not normally recommended, as these locations occasionally experience
c
onditions that can result in improper operation.”
C
alifornia State Fire Marshal (CSFM)
Early warning detection is best achieved by the installation of fire
d
etection equipment in all rooms and areas of the household as follows:
A Smoke Alarm installed in each separate sleeping area (in the vicinity,
but outside bedrooms), and Heat or Smoke Alarms in the living rooms,
d
ining rooms, bedrooms, kitchens, hallways, finished attics, furnace
rooms, closets, utility and storage rooms, basements, and attached
garages.
Printed in Mexico M08-0182-002 K1 08/08
First Alert
®
is a registered trademark of the First Alert Trust.
BRK Brands, Inc., ("BRK") the maker of First Alert
®
brand pr
oducts
w
arrants that for a period of five years from the date of purchase, this
product will be free from defects in material and workmanship. BRK, at
its option, will repair or replace this product or any component of the
p
ro
duct found to be defective during the warranty period. Replacement
will be made with a new or remanufactured product or component.
If the product is no longer available, replacement may be made with a
s
imilar product of equal or greater value. This is your exclusive warranty.
T
his warranty is valid for the original retail purchaser from the date of
initial retail purchase and is not transferable. Keep the original sales
r
eceipt. Pr
oof of pur
chase is r
equir
e
d to obtain warranty performance.
B
RK dealers, service centers, or retail stores selling BRK products do
not have the right to alter, modify or any way change the terms and
conditions of this warranty
.
This warranty does not cover normal wear of parts or damage resulting
from any of the following: negligent use or misuse of the pr
oduct,
use on improper voltage or current, use contrary to the operating
instructions, disassembly, repair or alteration by anyone other than
BRK or an authorized service center. Further, the warranty does not
cover Acts of God, such as fir
e, flood, hurricanes and tornadoes or
any batteries that are included with this unit.
BRK shall not be liable for any incidental or consequential damages
c
aused by the breach of any express or implied warranty. Except to
the extent prohibited by applicable law, any implied warranty of
merchantability or fitness for a particular purpose is limited in duration
t
o the duration of the above warranty.
Some states, provinces or
jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty
l
asts, so the above limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have
other rights that vary fr
om state to state or pr
ovince to pr
ovince.
H
ow to Obtain Warranty Service
Ser
vice:
If service is r
equir
ed, do not r
etur
n
the pro
duct to your re
tailer.
I
n ord
er to obtain warranty service, contact the Consumer Affairs
Division at 1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time,
Monday through Friday. To assist us in serving you, please have the
model number and date of purchase available when calling.
For Warranty Service return to:
BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906
Battery: BRK Brands, Inc. make no warranty, express or implied,
written or oral, including that of merchantability or fitness for any
particular purpose with respect to battery.
TROUBLESHOOTING GUIDE
I
f the Alarm... Problem... You should...
H
orn "chirps" about once per minute;
G
reen
"
Smoke/CO"
L
ED flashes Green On for
2 seconds/Off for 2 seconds. (Low Battery
L
atch is engaged.)
L
ow battery warning. Install two new AA batteries
*.
H
orn does three rapid "chirps" every minute;
L
ED has 3 rapid flashes with "chirps".
M
ALFUNCTION SIGNAL.
D
evice is not working
p
roperly, and needs to be replaced.
U
nits under warranty should be returned to
m
anufacturer for replacement. See “Limited
Warranty” for details.
C
arbon Monoxide Alarm
ONLY:
C
O Alarm goes back into alarm 4 minutes after
you Silence it.
C
O levels indicate a potentially dangerous
situation.
I
F YOU ARE FEELING SYMPTOMS OF CO
POISONING, EVACUATE your home and call
9
11 or the Fire Department. Refer to "If The
CO Alarm Sounds" for details.
C
O Alarm sounds fre
quently even though no h
igh
levels of CO are revealed in an investigation.
T
he CO Alarm may be impro
perly located. Refer
to “Where to Install This Alarm” for details.
R
elocate your Alarm. If fre
quent alarms
continue, have home rechecked for potential
CO problems. You may be experiencing an
i
ntermittent CO problem.
S
moke Alarm ONLY:
S
moke Alarm sounds when no smoke is visible. Unwanted alarm may be caused by non-
e
mergency source like cooking smoke.
S
ilence Alarm using manual button; clean the
A
larm’s cover with a soft, clean cloth. If frequent
unwanted alarms continue, relocate your Alarm.
A
larm may be too close to a kitchen, cooking
a
ppliance, or steamy bathro
om.
*F
or a list of acceptable re
placement batteries, see “Regular Maintenance.”
I
f you have questions that cannot be answere
d by re
ading this manual, call Consumer Aff
airs at 1-800-323-9005, M-F 7:30 a.m. to 5:00 p.m. (CST)
IF THE CO ALARM SOUNDS
A
ctuation of your CO Alarm indicates the presence of carbon
monoxide (CO) which can kill you. In other words, when your CO
Alarm sounds, you must not ignore it!
IF THE CO ALARM SIGNAL SOUNDS:
1
. Operate the Test/Silence button.
2. Call your emergency services, fire department or 911. Write down the
n
umber of your local emergency service here:
____________________________________________________________
3
. Immediately move to fresh air—outdoors or by an open door or
window. Do a head count to check that all persons are accounted
f
or. Do not re-enter the premises, or move away from the open door
o
r window until the emergency services responder has arrived, the
premises have been aired out, and your CO Alarm remains in its
n
ormal condition.
4. After following steps 1-3, if your CO Alarm reactivates within a 24-
h
our period, repeat steps 1-3 and call a qualified appliance
t
echnician to investigate for sources of CO from fuel-burning
equipment and appliances, and inspect for proper operation of this
e
quipment. If problems are identified during this inspection have the
e
quipment serviced immediately. Note any combustion equipment
not inspected by the technician, and consult the manufacturers’
i
nstructions, or contact the manufacturers directly, for more informa-
t
ion about CO safety and this equipment. Make sure that motor
vehicles are not, and have not, been operating in an attached
g
arage or adjacent to the residence. Write down the number of a
q
ualified appliance technician here:
_
___________________________________________________________
N
OTE:
A
qualified appliance technician is defined as “a person, firm,
c
orporation, or company that either in person or through a representative,
i
s engaged in and responsible for the installation, testing, servicing, or
r
eplacement of heating, ventilation, air conditioning (HVAC) equipment,
c
ombustion appliances and equipment, and/or gas fireplaces or other
d
ecorative combustion equipment.”
ALARM-MOVE TO FRESH AIR”
If you hear the CO alarm horn and the CO red light is flashing,
m
ove everyone to a source of fresh air.
DO NOT remove the batteries!
G
ENERAL LIMITATIONS OF SMOKE/CO ALARMS
For your r
ecords, please record:
Date Purchased: _______________________________
Where Purchased: __________________________________________
Date Installed: ____________/____________Month/Year
Replacement date is five years after installation: ________/______
Month/Year
NOTE: End of Life Signal — Once the unit reaches the end of its
lifecycle, the MALFUNCTION SIGNAL will sound once a minute to
indicate the need to immediately replace the Alarm.
LIMITED WARRANTY
I
F YOUR SMOKE/CO ALARM SOUNDS, Continued
T
ABLE
OF CONTENTS
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4
Where to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where This Alarm Should NOT Be Installed . . . . . . . . . . . . . . . . .2
How to Install This Smoke/CO Alarm . . . . . . . . . . . . . . . . . . . . .3-4
W
eekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
What You W
ill See and Hear W
ith This Alarm
. . . . . . . . . . . . . . . . . .
5
Locking Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
Regular Maintenance
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6
If Your Smoke/CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8
What To Do First–Identify The Type Of Alarm . . . . . . . . . . . . . . . .6
If the CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
If the Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Using the Silence Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Latching Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
“Smart Inter
connect” Featur
e . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . .8
What is CO?
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Finding the Source of CO After an Alarm . . . . . . . . . . . . . . . . . . .8
Potential Sour
ces of CO in the Home
. . . . . . . . . . . . . . . . . . . . . .
8
How Can I Protect My Family From CO Poisoning? . . . . . . . . . . . . .9
Regulatory Information For Smoke/CO Alarms . . . . . . . . . . . . . .9-10
Regulatory Information for CO Alarms . . . . . . . . . . . . . . . . . . . . . .9
Regulatory Information for Smoke Alarms
. . . . . . . . . . . . . . . . . . .9
Recommended Locations for Smoke Alarms . . . . . . . . . . . . . . . .9
Agency Placement Recommendations . . . . . . . . . . . . . . . . . . . .10
About Smoke Alarms
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . .10
General Limitations Of Smoke/CO Alar
ms
. . . . . . . . . . . . . . . . .
11-12
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-12
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-12

Produkspesifikasjoner

Merke: First Alert
Kategori: Røykvarsler
Modell: SC7010B
Vekt: 320 g
Bredde: 127 mm
Dybde: 127 mm
Høyde: 50.8 mm
Strømkilde: AC/DC
Tilkoblingsteknologi: Koblet med ledninger (ikke trådløs)
Detektortype: Optical reflekterende detektor
Produktfarge: Hvit
Kompatible batteristørrelser: AA
Reserve batteri: Ja

Trenger du hjelp?

Hvis du trenger hjelp med First Alert SC7010B still et spørsmål nedenfor, og andre brukere vil svare deg




Røykvarsler First Alert Manualer

Røykvarsler Manualer

Nyeste Røykvarsler Manualer