Tripp Lite PDU3XMV6G32 Bruksanvisning

Tripp Lite grenuttak PDU3XMV6G32

Les nedenfor 📖 manual på norsk for Tripp Lite PDU3XMV6G32 (72 sider) i kategorien grenuttak. Denne guiden var nyttig for 6 personer og ble vurdert med 4.9 stjerner i gjennomsnitt av 3.5 brukere

Side 1/72
1
Owner’s Manual
3-Phase Metered 0U
Power Distribution Unit
(Phase and Bank Measurements)
PDU3XMV6G32
(Series Number: AG-00BD)
Important Safety Instructions 2
Installation 3
Digital Display 5
Using the Digital Display 6
Features 12
Service 13
Warranty and 14
Product Registration
Español 15
Français 29
Русский 43
Deutsch 57
TrippLite.Eaton.com/support
Copyright © 2023 Tripp Lite. All rights reserved.
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
2
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during
the installation, operation, and storage of this product. Failure to heed these
instructions and warnings may affect the product warranty.
CAUTION Only those who are properly trained or qualified to use this device should
do so. Anyone who is not trained or qualified should not use this device unless it is under
the supervision of someone who is properly trained or qualified to do so.
Children must be supervised to ensure that they do not use the device as a toy.
Never use the device if the cord and plug are damaged; if it is not working properly,
or if it has been dropped or damaged, take it to an authorized service center for inspection
and repair.
If the power cord is damaged, it must be replaced by the manufacturer, its authorized
service agent, or by qualified personnel in order to avoid a danger.
The PDU provides the convenience of multiple outlets, but DOES NOT provide surge or line noise
protection for connected equipment.
The PDU is designed for indoor use only, in a controlled environment, away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
Keep indoor ambient temperature between 32°F and 122°F (0°C and 50°C).
• ThePDUmustbeinstalledbyaqualiedtechnicianonly.
Do not attempt to mount the PDU to an insecure or unstable surface.
Install in accordance with National Electrical Code standards. Be sure to use the proper
overcurrent protection for the installation, in accordance with the plug/equipment rating.
Connect the PDU to an outlet that is in accordance with your local building codes and that is
adequately protected against excess currents, short circuits and earth faults.
The electrical outlets supplying power to the equipment should be installed near the equipment
and easily accessible.
Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that
eliminate the connection to ground.
Be sure to provide a local disconnect device on any models that are permanently installed
without a plug that is easily accessible.
Never attempt to install electrical equipment during a thunderstorm.
Individual equipment connected to the PDU should not draw more current than the individual
PDU’s outlet’s rating.
The total load connected to the PDU must not exceed the maximum load rating for the PDU.
Do not attempt to modify the PDU, input plugs or power cables.
Do not drill into or attempt to open any part of the PDU housing. There are no user-serviceable
parts inside.
Do not attempt to use the PDU if any part of it becomes damaged.
Use of this equipment in life support applications where failure of this equipment can
reasonablybeexpectedtocausethefailureofthelifesupportequipmentortosignicantly
affect its safety or effectiveness is not recommended. Do not use this equipment in the
presenceofaammableanestheticmixturewithair,oxygenornitrousoxide.

Produkspesifikasjoner

Merke: Tripp Lite
Kategori: grenuttak
Modell: PDU3XMV6G32
Vekt: 6480 g
Bredde: 55.1 mm
Dybde: 63.2 mm
Høyde: 1778 mm
LED-indikatorer: Ja
Opprinnelsesland: Taiwan
Pakkevekt: 9300 g
Sertifisering: Tested to CE (IEC 60950-1, EN55022, EN55024), EN Class A (Emissions), TAA Compliant
AC-inngangsfrekvens: 50 - 60 Hz
Kabellengde: 1.83 m
Produktfarge: Sort
Pakkedybde: 1944.9 mm
Pakkehøyde: 175 mm
Pakkebredde: 150.1 mm
Driftstemperatur (T-T): 0 - 50 °C
Oppbevaringstemperaturomåde (Celsius): -15 - 60 °C
Bærekraftsertifikater: RoHS
Kroppsmateriale: Metall
Montering: Vertikal
Strømbeskyttelsesfunksjoner: Overbelastning
Driftshøyde: 0 - 3000 m
Av/på-bryter: Ja
Rack-kapasitet: 0U
Relativ luftfuktighet under drift (H-H): 5 - 95
Maksimal styrke: 23000 W
Antall AC outlets: 42 AC-utganger
Produkter per masterkasse (ytterkasse): 1 stykker
Strøm (maks.): 32 A
AC-utgangstyper: C13 coupler, C19 coupler
Strømuttak: IEC309
Nominell innputspenning: 380-400 V
PDU types: Målte
Nominell outputspenning: 200-240 V
Maksimal totalt strømforbruk per fase: 16 A
Master AC uttak kvantitet: 36
Slave AC antall utganger: 6

Trenger du hjelp?

Hvis du trenger hjelp med Tripp Lite PDU3XMV6G32 still et spørsmål nedenfor, og andre brukere vil svare deg